Sharp AY-ZP48LZ Plasmacluster Operation Self Clean Operation, Press the Self Clean button

Page 14

PLASMACLUSTER OPERATION

 

SELF CLEAN OPERATION

 

 

 

Plasmacluster ions released into the room will reduce some airborne mold and viruses.

1 During operation, press the PLASMACLUSTER button.

• The remote control will display “

”.

The blue PLASMACLUSTER lamp on the unit will light up.

1

TO CANCEL

Press the PLASMACLUSTER button again.

The PLASMACLUSTER lamp on the unit will turn off.

NOTE:

Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next time you turn on the unit.

To turn off the PLASMACLUSTER lamp, press the DISPLAY button.

To perform Plasmacluster operation in FAN only mode, press the PLASMACLUSTER button when the unit is not operating.

The mode symbol of the remote control will go off and the fan speed cannot be set to AUTO.

SELF CLEAN operation using Plasmacluster ions helps to reduce the growth mold fungus and dry inside of the unit. It is recommended to utilize the operation at seasonal change over.

1 Press the SELF CLEAN button when the unit is not operating.

• The remote control displays “

”.

The blue PLASMACLUSTER lamp on the unit will light up.

The unit will stop operation after 40 minutes.

1

TO CANCEL

Press the SELF CLEAN button.

The blue PLASMACLUSTER lamp on the unit will turn off.

NOTE:

You cannot set the temperature, fan speed, air flow direction or timer setting during the SELF CLEAN operation.

Mold fungus already in existence can not be eliminated by this operation.

12

Image 14
Contents AY-ZP48LZ AE-Z48LZ Page Important Safety Instructions ContentsImportant Safety InstructionsOutdoor Unit Part NamesIndoor Unit Remote Control Remote Control Display Transmitter DisplayLoading Batteries Using the Remote ControlHOW to USE the Remote Control SET Current Clock TimeTips on Saving Energy Setting AIR Purifying FIL- TERAuxiliary Mode To change the fan speed, press the FAN button Basic OperationPress the COOL, DRY or Heat button To turn off the unit, press the Stop buttonPress the Swing button Adjusting the AIR Flow DirectionVertical AIR Flow Direction Horizontal AIR Flow Direction Vertical airflow louvre will swingDuring operation, press the Coanda Airflow button Coanda AirflowSpot AIR Press the Coanda Airflow button againPress the Full Power button again Full Power Operation Energy Saving OperationDuring operation, press the Full Power button Press the Energy Save button againTimer OFF Timer OperationPress the 1.2.3.5h OFF Timer button to set the desired time Press the Timer OFF ButtonTo Change Time Setting Timer onTo Cancel Timer Mode Combined USE of on and OFF TimersPress the Self Clean button Plasmacluster Operation Self Clean OperationPress the Self Clean button when the unit is not operating During operation, press the Plasmacluster buttonAdditional Notes on Operation Operating Temperature RangeVacancy Operation Press the Heat button Press the Vacancy buttonMaintenance Check the following points before calling for service Before Calling for ServiceSpecifications Following conditions do not denote equip- ment malfunctionsPage