Installation / Operation

6

ELECTRICAL CONNECTION

Hazardous voltage. Risk of dangerous or fatal electric shock. Plug the pump into a 115 Volt, 60 Cycle, Ground Fault Circuit Interrupter (GFCI) protect- ed grounded outlet only. The pump is equipped with a 3-wire grounded cord and plug. Do not modify or remove the plug. Make sure the outlet meets the National Electric Code or the Canadian Electrical Code, as applicable. To avoid dangerous electrical shock haz- ard, keep the cord dry at all times. See Figure 2.

AUTOMATIC PRESSURE CONTROLLER

The Automatic Pressure Controller mounts on the pump. It protects against:

Run-dry operation;

Overheating;

Frequent starts caused by small water losses in the system;

Pressure drop.

The Automatic Pressure Controller features the following LEDs and controls:

“POWER ON” LED: indicates that the unit is electrically connected and that voltage is present. The pump is ready to operate.

“PUMP ON” LED: indicates that the pump is running and actually pumping water.

“WATER FAILURE” LED: indicates that no water is detected coming into the pump.

“TEMPERATURE FAILURE” LED: indicates that the tem- perature inside the pump has reached 158° F (70° C).

Reset

Water Failure LED

Temp. Failure LED

Pump-on LED

Power-on LED

 

 

 

 

 

WATER

RESET

 

 

 

 

 

FAILURE

 

 

 

PUMP

TEMP.

 

 

 

 

ON

FAILURE

 

 

 

POWER

 

 

 

 

STARTING

20

ON

 

 

 

 

25

 

 

 

 

 

PRESSURE

 

 

 

30

 

 

 

Starting

15

 

 

 

 

35

 

®

Pressure

PSI

45

 

40

 

 

 

 

 

 

 

 

Dial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-

 

 

 

 

 

 

 

 

800-

 

 

 

 

 

 

 

www.

468-

 

 

 

 

 

 

simerpump.

 

 

 

 

 

 

 

 

7867

 

 

 

 

 

 

 

 

com

®

 

 

 

 

 

 

 

 

Figure 4 - Control Panel

“Starting Pressure” dial: allows you to set the system pressure at 15 to 45 psi (103 to 310 kPa). The pump will start automatically when the system pressure drops below the pressure point which you have set on the “Starting Pressure” dial.

“Reset” button: resets any safeties which have tripped and allows the pump to restart.

NOTE: The unit will not respond if the ‘RESET’ button is held down. It must be pressed and released to activate the reset function.

NORMAL OPERATION OF THE 3075SS

Burn Hazard. NEVER run the pump dry. Running the pump without water may cause pump to overheat and cause burns to persons handling the pump. It may also damage the impeller and may damage the seal, causing leaking or flooding, and will void the war- ranty. Fill the pump with water before starting it.

Make sure that the 3075SS has been properly installed, primed (see page 4), and that the suction pipe is unob- structed and open.

Turn the ‘STARTING PRESSURE’ dial to the minimum desired system pressure.

Plug in the pump. The ‘POWER ON’ and ‘PUMP ON’ lights will come on indicating, respectively, that voltage is present and that the pump is ready to operate.

The pump will start and will continue to operate until 15 seconds after the system pressure has risen past the set- point on the “STARTING PRESSURE” dial and flow has stopped.

WHEN DOES THE PUMP

STOP OPERATING?

Pressure Set-Point/No Flow: The pump will stop operat- ing and the ‘PUMP ON’ LED will go off 15 seconds after:

The system pressure is above the point set by the STARTING PRESSURE dial, and

The flow has stopped. This is normal operation.

Restart: A water flow in the system greater than

1 GPM or a drop in pressure below the STARTING PRESSURE set-point will cause the pump to restart and the ‘PUMP ON’ LED to light up. The pump will contin- ue to operate until 15 seconds after:

It reaches the set pressure, and

The flow stops.

NOTE: The 15-second delay in shutting off the pump prevents rapid cycling when water faucets are being turned on and off quickly (for example, when brushing teeth, etc.).

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 6
Contents Automatique Installation/Operation/PartsAutomatic Booster Pump Bomba automática de refuerzoGeneral Safety SafetyRead and Follow Safety Instructions Electrical SafetyTable of Contents General Information / Installation InstallationGeneral Information Installation Electrical Connection Installation / OperationWhen does the Pump Stop OPERATING? Normal Operation of the 3075SSTroubleshooting Operation / Service / TroubleshootingPump Service LubricationRepair Parts Ace-In-The-Hole Series Model 3075SSKey Part 3075SS Description Page Consignes DE Sécurité Générales Ce symbole indique qu’il faut être prudent. Lorsque ceSécurité Laver. Ne pas l’immerger. Le protéger contre la pluieTable des matières PagesRenseignements généraux et Installation Renseignements GénérauxVers Househl’habitatioldn WaterArrivée Supply ’eau Servorégulateur Installation et fonctionnementBranchements Électriques Fonctionnement Normal DE LA Pompe PressuremateEntretien DE LA Pompe Fonctionnement, entretien et dépannageLubrification DépannageDésignation 3075SS Pièces de rechangeSérie Ace-In-The-Hole, modèle 3075SS Des pièces QtéPage Seguridad Instrucciones Generales DE SeguridadEste es el símbolo de alerta de seguridad. Cuando vea Índice PáginaInformación general / Instalación Información GeneralInstalación Instalación Controlador Automático DE Presión Instalación / OperaciónConexiones Eléctricas Funcionamiento Normal DE LA PressuremateServicio DE LA Bomba Operación / Servicio / Localización de fallasLubricación Localización DE FallasRepuestos para la reparación Modelo 3075SS de la Serie Ace-in-the-hole La mejor bazaClave Descripción 3075SS De la pieza
Related manuals
Manual 16 pages 29.62 Kb

3075SS specifications

Simer Pumps has established itself as a trusted name in the water pump industry, providing high-quality products that cater to various applications. Among their lineup, the Simer Pumps 3075SS, 2955-01, A5500, 2957, and 2957-01 models stand out for their performance, durability, and innovative technologies.

The Simer 3075SS is a stainless steel submersible pump designed for heavy-duty applications. Its robust construction offers exceptional corrosion resistance, making it ideal for residential and commercial use in demanding environments. This pump features an efficient motor that can handle both clear and slightly contaminated water, boasting a maximum flow rate of up to 75 gallons per minute. The automatic float switch ensures hands-free operation, activating the pump when water reaches a predetermined level.

The Simer 2955-01 is another reliable option, perfect for draining basements, flooded areas, or swimming pools. This submersible utility pump is lightweight and easy to transport, yet it doesn't compromise on efficiency. With a maximum flow rate of 30 gallons per minute, the 2955-01 is equipped with a powerful motor that enables continuous operation. The built-in overload protection safeguards the pump from potential damage, extending its lifespan.

Next in the lineup is the Simer A5500, a versatile high-capacity utility pump designed for more demanding applications. With its durable construction, this pump can handle larger volumes of water, making it suitable for commercial and industrial settings. The A5500 boasts a maximum pumping capacity of 70 gallons per minute, and its rugged design enables it to operate effectively in both fresh and saltwater environments. This model also comes with a thermal overload switch that provides additional protection against overheating.

The Simer 2957 and 2957-01 models are designed with user convenience in mind. These submersible pumps guide water away from flooded areas efficiently. They provide a maximum flow rate of 30 gallons per minute and feature an adjustable float switch for customizable operation. The lightweight design makes them easy to transport, while the thermoplastic construction ensures longevity and resistance to corrosion.

In conclusion, Simer Pumps' models 3075SS, 2955-01, A5500, 2957, and 2957-01 exemplify the company’s commitment to quality and reliability. With their robust construction, intuitive features, and advanced technologies, these pumps meet the diverse needs of consumers and professionals alike, ensuring efficient water management across various applications.