Simer Pumps 3075SS owner manual General Information / Installation

Page 4

General Information / Installation

4

Use the 3075SS to boost city water pressure. Plumbing connections are described in this manual.

GENERAL INFORMATION

Pump only clean water with your 3075SS. To avoid clogging the pump and damaging the shaft seal, do not pump water containing solids, foreign material, sand, silt, or abrasives.

If you are boosting the pressure from a well pump, be sure that the system check valves are tight. If the sys- tem pressure drops when the well pump is not run- ning, the 3075SS may start and cycle. Excessive or rapid cycling may damage the motor and will void the warranty.

Do not use pipe joint compound on pump ports; use only teflon tape to seal the threads. Pipe joint com- pound will damage the controller materials.

NOTE: The priming plug has an O-ring already installed and does not require sealing.

Tighten all the piping joints to the pump hand tight plus 1-1/2 turns (not more).

Overtightening may break the pump and will void the warranty.

Pipe and fittings to the pump should be at least nomi- nal 1” diameter. Pipe or fittings less than 1” in diame- ter will reduce performance and may damage the pump through cavitation.

Make sure that there are no air leaks or air pockets in the suction pipe. An air leak in the suction pipe may draw air in, although no water leaks out. Air leaks and air pockets will prevent the pump from priming prop- erly, and can substantially reduce its performance.

The pump mount should be level, solid, as near as possible to the water source, and protected against excess moisture and flooding.

Use the shortest possible run for piping and the smallest possible number of fittings. Long pipe runs and numerous fittings increase friction and reduce the flow of water.

Support the weight of the piping and pump.

Do not allow the pump, pressure controller, or any system components to freeze. Freezing will damage the pump and void the warranty.

Periodically inspect the pump, pressure controller, and system components.

NOTE: Local code may require a pressure relief valve or pressure regulator.

Risk of leaks and flooding. Do not use this pump with inlet pressure greater than 50 psi (345 kPa).

Pressure hazard and risk of explosion. This pump can develop high pressure when operated with the discharge shut off or obstructed. For safe operation, we recommend the following:

If not already in the plumbing system, install a pressure relief valve in the pump discharge line capable of pass-

ing the full pump flow at 100 psi (689 kPa) (See Figure

2). If local code requires installation of a pressure relief valve capable of handling the full pump flow at a pres- sure less than 100 psi (689 kPa), follow the code require- ments. Run the relief valve discharge to a floor drain or other drain that will give adequate runoff.

Figure 1 – Do Not Run the Pump With Inlet Shut Off

Grounded, GFCI protected 115V outlet

To Household

(Pump Discharge)

Unions

 

Check Valve

Water Supply In

4253 0902 SIM

(Pump Suction)

Figure 2:Typical household booster installation. Purchase plumbing fittings separately. Consult code for relief valve/pressure regulator requirements.

INSTALLATION

Risk of flooding. Be sure that all plumbing and fittings are rated to withstand the system pressure which you expect the pump to generate.

1.Decide what’s the best place to install the pump. Think about these things:

it must be near the main water supply line

the pump must be accessible

the power cord must reach a power outlet

the controller’s LED lights must be visible

ease of plumbing

space saving

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 4
Contents Installation/Operation/Parts Automatic Booster PumpAutomatique Bomba automática de refuerzoSafety Read and Follow Safety InstructionsGeneral Safety Electrical SafetyTable of Contents Installation General Information / InstallationGeneral Information Installation Installation / Operation When does the Pump Stop OPERATING?Electrical Connection Normal Operation of the 3075SSOperation / Service / Troubleshooting Pump ServiceTroubleshooting LubricationAce-In-The-Hole Series Model 3075SS Repair PartsKey Part 3075SS Description Page Ce symbole indique qu’il faut être prudent. Lorsque ce SécuritéConsignes DE Sécurité Générales Laver. Ne pas l’immerger. Le protéger contre la pluieTable des matières PagesRenseignements généraux et Installation Renseignements GénérauxVers Househl’habitatioldn WaterArrivée Supply ’eau Installation et fonctionnement Branchements ÉlectriquesServorégulateur Fonctionnement Normal DE LA Pompe PressuremateFonctionnement, entretien et dépannage LubrificationEntretien DE LA Pompe DépannagePièces de rechange Série Ace-In-The-Hole, modèle 3075SSDésignation 3075SS Des pièces QtéPage Instrucciones Generales DE Seguridad SeguridadEste es el símbolo de alerta de seguridad. Cuando vea Índice PáginaInformación General Información general / InstalaciónInstalación Instalación Instalación / Operación Conexiones EléctricasControlador Automático DE Presión Funcionamiento Normal DE LA PressuremateOperación / Servicio / Localización de fallas LubricaciónServicio DE LA Bomba Localización DE FallasModelo 3075SS de la Serie Ace-in-the-hole La mejor baza Repuestos para la reparaciónClave Descripción 3075SS De la pieza
Related manuals
Manual 16 pages 29.62 Kb

3075SS specifications

Simer Pumps has established itself as a trusted name in the water pump industry, providing high-quality products that cater to various applications. Among their lineup, the Simer Pumps 3075SS, 2955-01, A5500, 2957, and 2957-01 models stand out for their performance, durability, and innovative technologies.

The Simer 3075SS is a stainless steel submersible pump designed for heavy-duty applications. Its robust construction offers exceptional corrosion resistance, making it ideal for residential and commercial use in demanding environments. This pump features an efficient motor that can handle both clear and slightly contaminated water, boasting a maximum flow rate of up to 75 gallons per minute. The automatic float switch ensures hands-free operation, activating the pump when water reaches a predetermined level.

The Simer 2955-01 is another reliable option, perfect for draining basements, flooded areas, or swimming pools. This submersible utility pump is lightweight and easy to transport, yet it doesn't compromise on efficiency. With a maximum flow rate of 30 gallons per minute, the 2955-01 is equipped with a powerful motor that enables continuous operation. The built-in overload protection safeguards the pump from potential damage, extending its lifespan.

Next in the lineup is the Simer A5500, a versatile high-capacity utility pump designed for more demanding applications. With its durable construction, this pump can handle larger volumes of water, making it suitable for commercial and industrial settings. The A5500 boasts a maximum pumping capacity of 70 gallons per minute, and its rugged design enables it to operate effectively in both fresh and saltwater environments. This model also comes with a thermal overload switch that provides additional protection against overheating.

The Simer 2957 and 2957-01 models are designed with user convenience in mind. These submersible pumps guide water away from flooded areas efficiently. They provide a maximum flow rate of 30 gallons per minute and feature an adjustable float switch for customizable operation. The lightweight design makes them easy to transport, while the thermoplastic construction ensures longevity and resistance to corrosion.

In conclusion, Simer Pumps' models 3075SS, 2955-01, A5500, 2957, and 2957-01 exemplify the company’s commitment to quality and reliability. With their robust construction, intuitive features, and advanced technologies, these pumps meet the diverse needs of consumers and professionals alike, ensuring efficient water management across various applications.