Simer Pumps 3075SS Read and Follow Safety Instructions, General Safety, Electrical Safety

Page 2

Safety

2

READ AND FOLLOW

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.

warns about hazards that will cause serious personal injury, death or major property damage if ignored.

warns about hazards that can cause serious personal injury, death or major property damage if ignored.

warns about hazards that will or can cause minor personal injury or property damage if ignored.

The label NOTICE indicates special instructions which are important but not related to hazards.

Carefully read and follow all safety instructions in this manual and on pump.

Keep safety labels in good condition.

Replace missing or damaged safety labels.

Make workshops childproof; use padlocks and master switches; remove starter keys.

GENERAL SAFETY

1.To avoid risk of serious bodily injury and property damage, read the safety instructions carefully before installing this pump.

2.Follow local and/or national plumbing, building and electrical codes when installing the pump. Use rigid pipe when installing this pump.

3. Hazardous Pressure. The pump body may explode if used to boost pressure above 100 psi (689 kPa). Do not use this pump with inlet pressure greater than 50 psi (345 kPa). If not already in the plumbing system, install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi (689 kPa). If local code requires installation of a pressure relief valve capable of han- dling the full pump flow at a pressure less than 100 psi (689 kPa), follow the code requirements.

4.A low pressure safety cutoff switch is recommended to shut off power to the pump in case of low dis- charge pressure due to interruption of the incoming water supply, broken pipe, etc.

5.Never run the pump dry. To do so can damage inter- nal parts, overheat pump (which can cause burns to people handling or servicing pump), and will void warranty.

6. Risk of fire or explosion. To avoid risk of fire and explosion, Pump Water Only with this pump. Do not pump flammable liquids or chemicals. Do not use the pump near gas pilot lights or where chemical or gas fumes are present. Use of an electric pump with liquids other than water or in an atmos- phere containing chemical or gas fumes may ignite those liquids or gases and cause injury or death due to an explosion and/or fire.

7. Burn Hazard. If water is trapped in the pump during operation it may turn to steam. Trapped steam can lead to an explosion and burns. Never run the pump with the outlet closed or obstructed.

8. Do not touch an operating motor. Modern motors can operate at high temperatures. To avoid burns when servicing the pump, allow it to cool for 20 minutes after shut-down before handling.

ELECTRICAL SAFETY

The pump is supplied with a 3-conductor ground- ing type cord. Connect only to a properly ground- ed, GFCI protected outlet. Do not lift the pump by the

electrical cord.

Hazardous voltage. Can shock, burn or cause death. Ground the pump before connecting to a power supply. Disconnect the power before working on the pump, motor or tank.

The pump and controller are non-submersible. Keep the motor dry at all times. Do not wash the

motor. Do not immerse. Protect the motor from wet weather.

If using an extension cord, use only an approved indoor/outdoor, 3-wire, grounding type cord. Do

not allow any part of the cord or the receptacle ends to sit in water or in damp locations.

Unplug the pump before servicing. To avoid

fatal shock, proceed as follows if the pump needs servicing.

A.Disconnect the power to the pump outlet box before unplugging the pump. After the plug is pulled, let the pump cool for 20 minutes before attempting to work on it.

B.Take extreme care when changing fuses. To reduce the chance of fatal electrical shock, DO NOT stand in water or put your finger in the fuse socket.

C.Ground the electrical outlet box.

D.Plug the pump and the controller into a Ground Fault Circuit Interrupter (GFCI) protected grounded outlet only.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 2
Contents Automatique Installation/Operation/PartsAutomatic Booster Pump Bomba automática de refuerzoGeneral Safety SafetyRead and Follow Safety Instructions Electrical SafetyTable of Contents General Information General Information / InstallationInstallation Installation Electrical Connection Installation / OperationWhen does the Pump Stop OPERATING? Normal Operation of the 3075SSTroubleshooting Operation / Service / TroubleshootingPump Service LubricationKey Part 3075SS Description Repair PartsAce-In-The-Hole Series Model 3075SS Page Consignes DE Sécurité Générales Ce symbole indique qu’il faut être prudent. Lorsque ceSécurité Laver. Ne pas l’immerger. Le protéger contre la pluieTable des matières PagesRenseignements généraux et Installation Renseignements GénérauxVers Househl’habitatioldn WaterArrivée Supply ’eau Servorégulateur Installation et fonctionnementBranchements Électriques Fonctionnement Normal DE LA Pompe PressuremateEntretien DE LA Pompe Fonctionnement, entretien et dépannageLubrification DépannageDésignation 3075SS Pièces de rechangeSérie Ace-In-The-Hole, modèle 3075SS Des pièces QtéPage Este es el símbolo de alerta de seguridad. Cuando vea SeguridadInstrucciones Generales DE Seguridad Índice PáginaInstalación Información general / InstalaciónInformación General Instalación Controlador Automático DE Presión Instalación / OperaciónConexiones Eléctricas Funcionamiento Normal DE LA PressuremateServicio DE LA Bomba Operación / Servicio / Localización de fallasLubricación Localización DE FallasClave Descripción 3075SS De la pieza Repuestos para la reparaciónModelo 3075SS de la Serie Ace-in-the-hole La mejor baza
Related manuals
Manual 16 pages 29.62 Kb

3075SS specifications

Simer Pumps has established itself as a trusted name in the water pump industry, providing high-quality products that cater to various applications. Among their lineup, the Simer Pumps 3075SS, 2955-01, A5500, 2957, and 2957-01 models stand out for their performance, durability, and innovative technologies.

The Simer 3075SS is a stainless steel submersible pump designed for heavy-duty applications. Its robust construction offers exceptional corrosion resistance, making it ideal for residential and commercial use in demanding environments. This pump features an efficient motor that can handle both clear and slightly contaminated water, boasting a maximum flow rate of up to 75 gallons per minute. The automatic float switch ensures hands-free operation, activating the pump when water reaches a predetermined level.

The Simer 2955-01 is another reliable option, perfect for draining basements, flooded areas, or swimming pools. This submersible utility pump is lightweight and easy to transport, yet it doesn't compromise on efficiency. With a maximum flow rate of 30 gallons per minute, the 2955-01 is equipped with a powerful motor that enables continuous operation. The built-in overload protection safeguards the pump from potential damage, extending its lifespan.

Next in the lineup is the Simer A5500, a versatile high-capacity utility pump designed for more demanding applications. With its durable construction, this pump can handle larger volumes of water, making it suitable for commercial and industrial settings. The A5500 boasts a maximum pumping capacity of 70 gallons per minute, and its rugged design enables it to operate effectively in both fresh and saltwater environments. This model also comes with a thermal overload switch that provides additional protection against overheating.

The Simer 2957 and 2957-01 models are designed with user convenience in mind. These submersible pumps guide water away from flooded areas efficiently. They provide a maximum flow rate of 30 gallons per minute and feature an adjustable float switch for customizable operation. The lightweight design makes them easy to transport, while the thermoplastic construction ensures longevity and resistance to corrosion.

In conclusion, Simer Pumps' models 3075SS, 2955-01, A5500, 2957, and 2957-01 exemplify the company’s commitment to quality and reliability. With their robust construction, intuitive features, and advanced technologies, these pumps meet the diverse needs of consumers and professionals alike, ensuring efficient water management across various applications.