Simer Pumps 3075SS owner manual Installation

Page 5

Installation

5

NOTE: Installation of a low pressure safety cutoff switch on the pump discharge is recommended (and may be required by your local code) to shut off the power in case of low discharge pressure (caused by broken pipe, etc.).

2.Mount the pump on a solid base in the location you have decided on.

3.Choose a time that will allow you to shut off the water to the household while you install the 3075SS.

4.Shutoff the main water supply valve to the household.

5.Open any faucet to relieve water pressure in the plumbing. Once the water pressure is relieved, close the faucet.

6.READ STEP 6 COMPLETELY BEFORE STARTING TO WORK ON IT. You must remove a length of pipe from the main water supply line to allow installation of elbows for the 3075SS. The locations of the cuts must take into consideration the size of the elbows being used, the length of the threads in threaded joints or the overlap in glued or soldered joints, etc. Position the elbows in line with the pump suction and discharge threads. There may be slight water leakage while cutting the pipe. Remove any burrs or shavings caused by the cutting tool.

NOTE: Galvanized pipe may not need to be cut. If there is a union close to the pump location, disas- semble the union and remove (unscrew) pipe back past the pump location. Have new lengths of pipe cut and threaded to allow for the pump installation.

NOTE: Both female suction and male discharge ports have 1” NPT threads. Depending on your type of connection and the size of your home’s piping, you may need to install adapters on the ports.

7.Once the short piece of pipe is removed, the piping above the cut can be drained to prevent water mess. Place a pail under the opening going to the house- hold. Open the highest faucet in the system to let in air so the water can fall out of the pipes into the pail. Once it’s drained, close the faucet.

8.Install the elbows in the main water supply line. Point them toward the pump.

Risk of burst hose and flooding. Do not install with flexible hoses. Use only rigid piping that meets code.

9.Install piping from elbows to pump including a union in each line and a check valve in the pump suction line. The arrow on the check valve must point to the pump suction (see Figure 2). If not already in the plumbing system, install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi (689 kPa). If local code requires installation of a pressure relief valve capable of han- dling the full pump flow at a pressure less than 100 psi (689 kPa), follow the code requirements. A low pressure safety cutoff switch should also be installed in the discharge line, and may be required by your local codes.

10.With all pipe and fittings installed and sealed, turn on the main water supply slowly to pressurize the system and check for leaks. If any leaks appear, turn the main valve off, open a faucet to relieve the pressure, and repair the leak. Repeat this step until there are no leaks in the system.

11.Open a faucet to release the air from the pipes and allow water to flow. When a steady stream of water flows out of the faucet, the pump is full of water and fully primed. Close the faucet.

12.Turn the controller knob to the desired pressure for the pump to turn on. The 3075SS comes factory pre- set at 30 psi (207 kPa), and we recommend starting there and adjusting it later according to your experi- ence with the system.

13.Before continuing with the installation, see the sections of this manual titled “Electrical Connections”, “Automatic Pressure Controller”, “Normal Operation”, and “When Does The Pump Stop Operating” for detailed information on how the system functions.

14.At this point, you can plug in the pump for the first time. When you plug in the power cord, the pump will start and run for 15 seconds regardless of the controller setting. If the inlet pressure is above the set point, the pump will stop after 15 seconds.

15.When the pump is running and after it shuts off auto- matically, the system is at the boosted pressures. Inspect the pipe and fittings again for water leaks. If any leaks appear, unplug the pump, turn the water main valve off, open a faucet to relieve the pressure and repair the leak. Repeat this step until there are no leaks in the system.

To

Household

Water

Supply In

Figure 3:Typical bypass piping needed to allow removal of pump for repair without shutting down household water system.

For parts or assistance, call Simer Customer Service at 1-800-468-7867 /1-800-546-7867

Image 5
Contents Automatic Booster Pump Installation/Operation/PartsAutomatique Bomba automática de refuerzoRead and Follow Safety Instructions SafetyGeneral Safety Electrical SafetyTable of Contents General Information General Information / InstallationInstallation Installation When does the Pump Stop OPERATING? Installation / OperationElectrical Connection Normal Operation of the 3075SSPump Service Operation / Service / TroubleshootingTroubleshooting LubricationKey Part 3075SS Description Repair PartsAce-In-The-Hole Series Model 3075SS Page Sécurité Ce symbole indique qu’il faut être prudent. Lorsque ceConsignes DE Sécurité Générales Laver. Ne pas l’immerger. Le protéger contre la pluiePages Table des matièresRenseignements Généraux Renseignements généraux et InstallationVers Househl’habitatioldn WaterArrivée Supply ’eau Branchements Électriques Installation et fonctionnementServorégulateur Fonctionnement Normal DE LA Pompe PressuremateLubrification Fonctionnement, entretien et dépannageEntretien DE LA Pompe DépannageSérie Ace-In-The-Hole, modèle 3075SS Pièces de rechangeDésignation 3075SS Des pièces QtéPage Este es el símbolo de alerta de seguridad. Cuando vea SeguridadInstrucciones Generales DE Seguridad Página ÍndiceInstalación Información general / InstalaciónInformación General Instalación Conexiones Eléctricas Instalación / OperaciónControlador Automático DE Presión Funcionamiento Normal DE LA PressuremateLubricación Operación / Servicio / Localización de fallasServicio DE LA Bomba Localización DE FallasClave Descripción 3075SS De la pieza Repuestos para la reparaciónModelo 3075SS de la Serie Ace-in-the-hole La mejor baza
Related manuals
Manual 16 pages 29.62 Kb

3075SS specifications

Simer Pumps has established itself as a trusted name in the water pump industry, providing high-quality products that cater to various applications. Among their lineup, the Simer Pumps 3075SS, 2955-01, A5500, 2957, and 2957-01 models stand out for their performance, durability, and innovative technologies.

The Simer 3075SS is a stainless steel submersible pump designed for heavy-duty applications. Its robust construction offers exceptional corrosion resistance, making it ideal for residential and commercial use in demanding environments. This pump features an efficient motor that can handle both clear and slightly contaminated water, boasting a maximum flow rate of up to 75 gallons per minute. The automatic float switch ensures hands-free operation, activating the pump when water reaches a predetermined level.

The Simer 2955-01 is another reliable option, perfect for draining basements, flooded areas, or swimming pools. This submersible utility pump is lightweight and easy to transport, yet it doesn't compromise on efficiency. With a maximum flow rate of 30 gallons per minute, the 2955-01 is equipped with a powerful motor that enables continuous operation. The built-in overload protection safeguards the pump from potential damage, extending its lifespan.

Next in the lineup is the Simer A5500, a versatile high-capacity utility pump designed for more demanding applications. With its durable construction, this pump can handle larger volumes of water, making it suitable for commercial and industrial settings. The A5500 boasts a maximum pumping capacity of 70 gallons per minute, and its rugged design enables it to operate effectively in both fresh and saltwater environments. This model also comes with a thermal overload switch that provides additional protection against overheating.

The Simer 2957 and 2957-01 models are designed with user convenience in mind. These submersible pumps guide water away from flooded areas efficiently. They provide a maximum flow rate of 30 gallons per minute and feature an adjustable float switch for customizable operation. The lightweight design makes them easy to transport, while the thermoplastic construction ensures longevity and resistance to corrosion.

In conclusion, Simer Pumps' models 3075SS, 2955-01, A5500, 2957, and 2957-01 exemplify the company’s commitment to quality and reliability. With their robust construction, intuitive features, and advanced technologies, these pumps meet the diverse needs of consumers and professionals alike, ensuring efficient water management across various applications.