Miller Electric 575Volt manual Fumes and Gases can be hazardous, ARC Rays can burn eyes and skin

Page 6

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use local forced ventilation at the arc to remove welding fumes and gases.

DIf ventilation is poor, wear an approved air-supplied respirator.

DRead and understand the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air-supplied respirator. Always have a trained watch- person nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breath- ing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying op- erations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.

DWear an approved welding helmet fitted with a proper shade of fil- ter lenses to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).

DWear approved safety glasses with side shields under your helmet.

DUse protective screens or barriers to protect others from flash, glare and sparks; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant mate- rial (leather, heavy cotton, or wool) and foot protection.

WELDING can cause fire or explosion.

Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot equipment can cause fires and

burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.

DRemove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers.

DDo not weld where flying sparks can strike flammable material.

DProtect yourself and others from flying sparks and hot metal.

DBe alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.

DWatch for fire, and keep a fire extinguisher nearby.

DBe aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side.

DDo not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards).

DDo not weld where the atmosphere may contain flammable dust, gas, or liquid vapors (such as gasoline).

DConnect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock, sparks, and fire hazards.

OM-188 304 Page 2

DDo not use welder to thaw frozen pipes.

DRemove stick electrode from holder or cut off welding wire at contact tip when not in use.

DWear oil-free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes, and a cap.

DRemove any combustibles, such as a butane lighter or matches, from your person before doing any welding.

DAfter completion of work, inspect area to ensure it is free of sparks, glowing embers, and flames.

DUse only correct fuses or circuit breakers. Do not oversize or by- pass them.

DFollow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B for hot work and have a fire watcher and extinguisher nearby.

FLYING METAL or DIRT can injure eyes.

DWelding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag.

DWear approved safety glasses with side shields even under your welding helmet.

BUILDUP OF GAS can injure or kill.

DShut off shielding gas supply when not in use.

D Always ventilate confined spaces or use approved air-supplied respirator.

MAGNETIC FIELDS can affect Implanted

Medical Devices.

D Wearers of Pacemakers and other Implanted

Medical Devices should keep away.

DImplanted Medical Device wearers should consult their doctor and the device manufacturer before going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations.

NOISE can damage hearing.

Noise from some processes or equipment can damage hearing.

DWear approved ear protection if noise level is high.

CYLINDERS can explode if damaged.

Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.

DProtect compressed gas cylinders from excessive heat, mechani- cal shocks, physical damage, slag, open flames, sparks, and arcs.

DInstall cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping.

DKeep cylinders away from any welding or other electrical circuits.

DNever drape a welding torch over a gas cylinder.

DNever allow a welding electrode to touch any cylinder.

DNever weld on a pressurized cylinder − explosion will result.

DUse only correct shielding gas cylinders, regulators, hoses, and fit- tings designed for the specific application; maintain them and associated parts in good condition.

DTurn face away from valve outlet when opening cylinder valve.

DKeep protective cap in place over valve except when cylinder is in use or connected for use.

DUse the right equipment, correct procedures, and sufficient num- ber of persons to lift and move cylinders.

DRead and follow instructions on compressed gas cylinders, associated equipment, and Compressed Gas Association (CGA) publication P-1 listed in Safety Standards.

Image 6
Contents Description OM-188 304AFProcesses File MIG GmawFrom Miller to You Table of Contents Page Electric Shock can kill Symbol UsageArc Welding Hazards HOT Parts can cause severe burnsWelding can cause fire or explosion Fumes and Gases can be hazardousARC Rays can burn eyes and skin Flying Metal or Dirt can injure eyesFalling Unit can cause injury Welding Wire can cause injuryFire or Explosion hazard Moving Parts can cause injuryEMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion Risque D’INCENDIE OU D’EXPLO- Sion LE Bruit peut endommager l’ouïeLES Bouteilles peuvent exploser si elles sont endommagées LA Chute DE L’APPAREIL peut blesserProposition californienne 65 Avertissements LES Fils DE Soudage peuvent provoquer des blessuresLE Soudage À L’ARC risque de provoquer des interférences Principales normes de sécurité Information EMFEn ce qui concerne les implants médicaux OM-188 304 Specifications − IntroductionDuty Cycle And Overheating CC Mode CV Mode Volt-Ampere CurvesSelecting a Location − InstallationDimensions And Weight 610 mmWeld Output Receptacles And Selecting Cable Sizes ARC Welding can cause Electromagnetic Interference350 ft 400 ft Put terminals Remote 14 Receptacle Information Optional 115 Volt AC Duplex Receptacle And Circuit BreakersSocket Information Input Voltage Electrical Service GuideHz Three Phase Hz Single Min Grounding Conductor Size In AWGConnecting 1-Phase Input Power =GND/PE Earth GroundConnecting 3-Phase Input Power For Three-Phase Operation= GND/PE Earth Ground Power Switch − OperationFront Panel Controls Mode Meter Reading At Idle Meter Reading While Welding Meter FunctionsExample Displays Example Turn Output Adjust control to set arc length toSynergic Controls And Overview ControlsPress Increment or Decrement button until MIG appears Press Increment orStick appears Setup Screens Choosing Pulse Program Choosing Pulse Programs And Setting ParametersSetting Arc Length Choosing Adaptive Or Non AdaptiveOM-188 304 Overview Of Programs Wire Type Wire Size− Programs Individual Program Information175 529 362 400 323 498 127 342 529 174 370 108 221 388 134 268 390155 529 315 400 183 529 409 400505 298 140 194 400 213 196 501 286 205 529 359 249109 529 432 272 125 529 578 320107 529 435 337 140 274 529 199 280 258 294 317 310376 323 494 349150 529 370 381 100 310 529 145 330 190 354 235 365280 370 130 529 325 376 165 529 415 385− Maintenance & Troubleshooting Do not remove case when blowing out inside of unitBlowing Out Inside Of Unit Voltmeter/Ammeter Help Displays Detected. Have electrician check input power circuit Error CodesTroubleshooting Reset circuit breaker CB1 see SectionStart Your Professional Welding Career Now − Electrical Diagram Circuit Diagram For Welding Power Source 230/460 Volt ModelsCircuit Diagram For Welding Power Source 460/575 Volt Models − Parts List 59 57OM−188 304 Dia Part Description Quantity Mkgs PC2 +212 Material Thickness Gauge Work like a Pro Service Your distributor also givesSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s

575Volt, 460Volt, 230Volt specifications

Miller Electric is a leading manufacturer of welding and cutting equipment, renowned for its innovation and reliability. Among its extensive product line, Miller offers a variety of welding machines that operate on different voltage systems, specifically 230 Volt, 460 Volt, and 575 Volt models. Each of these voltages is designed to meet the needs of diverse applications and industries, from light fabrication to heavy industrial use.

Miller Electric’s 230 Volt machines are typically utilized in smaller workshops and for light to medium-duty applications. These machines are known for their portability, ease of use, and flexibility. They often feature inverter technology, which allows for compact designs and energy efficiency. This technology also helps in maintaining a stable arc, resulting in high-quality welds. The 230 Volt models are well-suited for MIG and TIG welding processes, offering versatility in material thickness and type.

The 460 Volt models are tailored for industrial settings that require greater power output. These machines deliver increased performance and are ideal for high-demand applications such as structural steel fabrication and heavy manufacturing. The robust design of the 460 Volt machines allows them to handle prolonged use and extreme conditions. Additionally, many of these units are equipped with advanced features such as digital display controls, programmable settings, and a variety of welding modes, enhancing user control and efficiency.

Finally, the 575 Volt models are designed for the most demanding environments, often seen in large-scale industrial operations. These machines provide exceptional power, allowing for welding of thicker materials and more complex joints. They also incorporate advanced cooling systems to handle the heat generated during extended welding sessions. The 575 Volt units may come equipped with enhanced safety features such as automatic shut-off and overload protection, ensuring reliable operation.

Miller Electric's commitment to innovation is reflected in the various technologies used in these voltage models. Features such as Auto-Set, which automatically adjusts parameters for different metals and thicknesses, streamline the welding process for users. Additionally, Miller's advanced inverter technology not only reduces energy consumption but also improves arc stability and consistency, leading to superior weld quality.

In summary, Miller Electric's 230 Volt, 460 Volt, and 575 Volt machines cater to a wide spectrum of welding needs, each with its unique set of features and advantages. The combination of portability, power, and advanced technology makes Miller Electric a trusted choice for welders across multiple industries.