Miller Electric 230Volt, 575Volt California Proposition 65 Warnings, Principal Safety Standards

Page 8

1-4. California Proposition 65 Warnings

Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)

Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers and Piping, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, website: www.nfpa.org and www. sparky.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 4221 Walney Road, 5th Floor, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cganet.com).

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 5060 Mississauga,

For Gasoline Engines:

Engine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproduc- tive harm.

For Diesel Engines:

Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

Ontario, Canada L4W 5NS (phone: 800-463-6727 or in Toronto

416-747-4044, website: www.csa-international.org).

Safe Practice For Occupational And Educational Eye And Face Protec- tion, ANSI Standard Z87.1, from American National Standards Institute,

25 West 43rd Street, New York, NY 10036–8002 (phone:

212-642-4900, website: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, Quincy, MA 02269-9101 (phone: 617-770-3000, web- site: www.nfpa.org.

OSHA, Occupational Safety and Health Standards for General Indus- try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super- intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954 (phone: 1-866-512-1800) (there are 10 Regional Offices—phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).

1-6. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them, or using a cable cover.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from opera- tor as practical.

5.Connect work clamp to workpiece as close to the weld as possi- ble.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the device manufacturer before performing or going near arc welding, spot welding, gouging, plasma arc cutting, or induction heating operations. If cleared by your doctor, then following the above procedures is recom- mended.

OM-188 304 Page 4

Image 8
Contents OM-188 304AF ProcessesDescription File MIG GmawFrom Miller to You Table of Contents Page Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal or Dirt can injure eyesWelding Wire can cause injury Fire or Explosion hazardFalling Unit can cause injury Moving Parts can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortLE Soudage peut provoquer un in cendie ou une explosion DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LE Bruit peut endommager l’ouïe LES Bouteilles peuvent exploser si elles sont endommagéesRisque D’INCENDIE OU D’EXPLO- Sion LA Chute DE L’APPAREIL peut blesserLE Soudage À L’ARC risque de provoquer des interférences Proposition californienne 65 AvertissementsLES Fils DE Soudage peuvent provoquer des blessures En ce qui concerne les implants médicaux Principales normes de sécuritéInformation EMF OM-188 304 Duty Cycle And Overheating Specifications− Introduction CC Mode CV Mode Volt-Ampere Curves− Installation Dimensions And WeightSelecting a Location 610 mm350 ft 400 ft Put terminals Weld Output Receptacles And Selecting Cable SizesARC Welding can cause Electromagnetic Interference Socket Information Remote 14 Receptacle InformationOptional 115 Volt AC Duplex Receptacle And Circuit Breakers Electrical Service Guide Hz Three Phase Hz SingleInput Voltage Min Grounding Conductor Size In AWGConnecting 1-Phase Input Power =GND/PE Earth Ground= GND/PE Earth Ground Connecting 3-Phase Input PowerFor Three-Phase Operation Front Panel Controls Power Switch− Operation Mode Meter Reading At Idle Meter Reading While Welding Meter FunctionsExample Displays Turn Output Adjust control to set arc length to Synergic Controls And OverviewExample ControlsStick appears Press Increment or Decrement button until MIG appearsPress Increment or Setup Screens Choosing Pulse Programs And Setting Parameters Setting Arc LengthChoosing Pulse Program Choosing Adaptive Or Non AdaptiveOM-188 304 Wire Type Wire Size − ProgramsOverview Of Programs Individual Program Information323 498 127 342 529 174 370 108 221 388 134 268 390 155 529 315 400175 529 362 400 183 529 409 400140 194 400 213 196 501 286 205 529 359 249 109 529 432 272505 298 125 529 578 320140 274 529 199 280 258 294 317 310 376 323107 529 435 337 494 349100 310 529 145 330 190 354 235 365 280 370 130 529 325 376150 529 370 381 165 529 415 385Blowing Out Inside Of Unit − Maintenance & TroubleshootingDo not remove case when blowing out inside of unit Voltmeter/Ammeter Help Displays Error Codes TroubleshootingDetected. Have electrician check input power circuit Reset circuit breaker CB1 see SectionStart Your Professional Welding Career Now − Electrical Diagram Circuit Diagram For Welding Power Source 230/460 Volt ModelsCircuit Diagram For Welding Power Source 460/575 Volt Models OM−188 304 − Parts List59 57 Dia Part Description Quantity Mkgs PC2 +212 Material Thickness Gauge Work like a Pro Support ServiceYour distributor also gives To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s

575Volt, 460Volt, 230Volt specifications

Miller Electric is a leading manufacturer of welding and cutting equipment, renowned for its innovation and reliability. Among its extensive product line, Miller offers a variety of welding machines that operate on different voltage systems, specifically 230 Volt, 460 Volt, and 575 Volt models. Each of these voltages is designed to meet the needs of diverse applications and industries, from light fabrication to heavy industrial use.

Miller Electric’s 230 Volt machines are typically utilized in smaller workshops and for light to medium-duty applications. These machines are known for their portability, ease of use, and flexibility. They often feature inverter technology, which allows for compact designs and energy efficiency. This technology also helps in maintaining a stable arc, resulting in high-quality welds. The 230 Volt models are well-suited for MIG and TIG welding processes, offering versatility in material thickness and type.

The 460 Volt models are tailored for industrial settings that require greater power output. These machines deliver increased performance and are ideal for high-demand applications such as structural steel fabrication and heavy manufacturing. The robust design of the 460 Volt machines allows them to handle prolonged use and extreme conditions. Additionally, many of these units are equipped with advanced features such as digital display controls, programmable settings, and a variety of welding modes, enhancing user control and efficiency.

Finally, the 575 Volt models are designed for the most demanding environments, often seen in large-scale industrial operations. These machines provide exceptional power, allowing for welding of thicker materials and more complex joints. They also incorporate advanced cooling systems to handle the heat generated during extended welding sessions. The 575 Volt units may come equipped with enhanced safety features such as automatic shut-off and overload protection, ensuring reliable operation.

Miller Electric's commitment to innovation is reflected in the various technologies used in these voltage models. Features such as Auto-Set, which automatically adjusts parameters for different metals and thicknesses, streamline the welding process for users. Additionally, Miller's advanced inverter technology not only reduces energy consumption but also improves arc stability and consistency, leading to superior weld quality.

In summary, Miller Electric's 230 Volt, 460 Volt, and 575 Volt machines cater to a wide spectrum of welding needs, each with its unique set of features and advantages. The combination of portability, power, and advanced technology makes Miller Electric a trusted choice for welders across multiple industries.