Miller Electric 460Volt, 575Volt, 230Volt manual Setup Screens

Page 28

5-6. Setup Screens

1

 

 

 

 

S e t u

p

 

 

A c c

e

s s i b l e P r o g r a m s

 

M a n u a l P u l s e M i g

 

> O f f

 

 

 

 

 

 

2

S e t u p

L a n g u a g e > E n g l i s h

To access Setup screens: turn welding power source Off, press and hold Select push button, turn unit On, and hold push button down until initial screen leaves.

To exit Setup screens, turn welding power source Off and then On again. Parameters that are dis- played when the Setup screens are exited are active.

1 Accessible Programs Screen

Select second line of display, and press Increment or Decrement but- ton until Accessible Programs is displayed.

Select third line of display and press Increment or Decrement button to access each program and the three modes as desired. Select the fourth line and press Increment or Decre- ment button to define each option On (accessible) or Off (not accessi- ble).

Programs and modes that are de- fined Off are not shown when the operator scrolls through the dis- plays in normal operation.

2 Language Screen

Select second line of display, and press Increment or Decrement but- ton until Language is displayed. Se- lect third line of display and press Increment or Decrement button un- til desired language is shown. The choices are English, French, Ital- ian, Spanish, and German.

OM-188 304 Page 24

Image 28
Contents OM-188 304AF ProcessesDescription File MIG GmawFrom Miller to You Table of Contents Page Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal or Dirt can injure eyesWelding Wire can cause injury Fire or Explosion hazardFalling Unit can cause injury Moving Parts can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut endommager l’ouïe LES Bouteilles peuvent exploser si elles sont endommagéesRisque D’INCENDIE OU D’EXPLO- Sion LA Chute DE L’APPAREIL peut blesserLES Fils DE Soudage peuvent provoquer des blessures Proposition californienne 65 AvertissementsLE Soudage À L’ARC risque de provoquer des interférences Information EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux OM-188 304 − Introduction SpecificationsDuty Cycle And Overheating CC Mode CV Mode Volt-Ampere Curves− Installation Dimensions And WeightSelecting a Location 610 mmARC Welding can cause Electromagnetic Interference Weld Output Receptacles And Selecting Cable Sizes350 ft 400 ft Put terminals Optional 115 Volt AC Duplex Receptacle And Circuit Breakers Remote 14 Receptacle InformationSocket Information Electrical Service Guide Hz Three Phase Hz SingleInput Voltage Min Grounding Conductor Size In AWGConnecting 1-Phase Input Power =GND/PE Earth GroundFor Three-Phase Operation Connecting 3-Phase Input Power= GND/PE Earth Ground − Operation Power SwitchFront Panel Controls Mode Meter Reading At Idle Meter Reading While Welding Meter FunctionsExample Displays Turn Output Adjust control to set arc length to Synergic Controls And OverviewExample ControlsPress Increment or Press Increment or Decrement button until MIG appearsStick appears Setup Screens Choosing Pulse Programs And Setting Parameters Setting Arc LengthChoosing Pulse Program Choosing Adaptive Or Non AdaptiveOM-188 304 Wire Type Wire Size − ProgramsOverview Of Programs Individual Program Information323 498 127 342 529 174 370 108 221 388 134 268 390 155 529 315 400175 529 362 400 183 529 409 400140 194 400 213 196 501 286 205 529 359 249 109 529 432 272505 298 125 529 578 320140 274 529 199 280 258 294 317 310 376 323107 529 435 337 494 349100 310 529 145 330 190 354 235 365 280 370 130 529 325 376150 529 370 381 165 529 415 385Do not remove case when blowing out inside of unit − Maintenance & TroubleshootingBlowing Out Inside Of Unit Voltmeter/Ammeter Help Displays Error Codes TroubleshootingDetected. Have electrician check input power circuit Reset circuit breaker CB1 see SectionStart Your Professional Welding Career Now − Electrical Diagram Circuit Diagram For Welding Power Source 230/460 Volt ModelsCircuit Diagram For Welding Power Source 460/575 Volt Models 59 57 − Parts ListOM−188 304 Dia Part Description Quantity Mkgs PC2 +212 Material Thickness Gauge Work like a Pro Your distributor also gives ServiceSupport To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s

575Volt, 460Volt, 230Volt specifications

Miller Electric is a leading manufacturer of welding and cutting equipment, renowned for its innovation and reliability. Among its extensive product line, Miller offers a variety of welding machines that operate on different voltage systems, specifically 230 Volt, 460 Volt, and 575 Volt models. Each of these voltages is designed to meet the needs of diverse applications and industries, from light fabrication to heavy industrial use.

Miller Electric’s 230 Volt machines are typically utilized in smaller workshops and for light to medium-duty applications. These machines are known for their portability, ease of use, and flexibility. They often feature inverter technology, which allows for compact designs and energy efficiency. This technology also helps in maintaining a stable arc, resulting in high-quality welds. The 230 Volt models are well-suited for MIG and TIG welding processes, offering versatility in material thickness and type.

The 460 Volt models are tailored for industrial settings that require greater power output. These machines deliver increased performance and are ideal for high-demand applications such as structural steel fabrication and heavy manufacturing. The robust design of the 460 Volt machines allows them to handle prolonged use and extreme conditions. Additionally, many of these units are equipped with advanced features such as digital display controls, programmable settings, and a variety of welding modes, enhancing user control and efficiency.

Finally, the 575 Volt models are designed for the most demanding environments, often seen in large-scale industrial operations. These machines provide exceptional power, allowing for welding of thicker materials and more complex joints. They also incorporate advanced cooling systems to handle the heat generated during extended welding sessions. The 575 Volt units may come equipped with enhanced safety features such as automatic shut-off and overload protection, ensuring reliable operation.

Miller Electric's commitment to innovation is reflected in the various technologies used in these voltage models. Features such as Auto-Set, which automatically adjusts parameters for different metals and thicknesses, streamline the welding process for users. Additionally, Miller's advanced inverter technology not only reduces energy consumption but also improves arc stability and consistency, leading to superior weld quality.

In summary, Miller Electric's 230 Volt, 460 Volt, and 575 Volt machines cater to a wide spectrum of welding needs, each with its unique set of features and advantages. The combination of portability, power, and advanced technology makes Miller Electric a trusted choice for welders across multiple industries.