Miller Electric Big Blue 500 PT HOT Parts can cause burns and injury, Fire or Explosion hazard

Page 8

HOT METAL from air arc cutting and gouging can cause fire or explosion.

DDo not cut or gouge near flammables.

DWatch for fire; keep extinguisher nearby.

HOT PARTS can cause burns and injury.

DDo not touch hot compressor or air system parts.

DLet system cool down before touching or ser- vicing.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servic- ing unit.

DStop engine and release air pressure before servicing.

DUse only genuine replacement parts from the manufacturer.

1-5. Additional Symbols For Installation, Operation, And Maintenance

FIRE OR EXPLOSION hazard.

D Do not install or place unit on, over, or near combustible surfaces.

DDo not install unit near flammables.

DDo not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.

WELDING WIRE can cause injury.

DDo not press gun trigger until instructed to do so.

DDo not point gun toward any part of the body, other people, or any metal when threading welding wire.

FALLING UNIT can cause injury.

DUse lifting eye to lift unit and properly installed accessories only, NOT gas cylinders. Do not exceed maximum lift eye weight rating (see Specifications).

DLift and support unit only with proper equipment and correct procedures.

DIf using lift forks to move unit, be sure forks are long enough to extend beyond opposite side of unit.

OVERHEATING can damage motors.

DTurn off or unplug equipment before starting or stopping engine.

DDo not let low voltage and frequency caused by low engine speed damage electric motors.

DDo not connect 50 or 60 Hertz motors to the 100 Hertz receptacle where applicable.

FLYING SPARKS can cause injury.

D Wear a face shield to protect eyes and face.

D Shape tungsten electrode only on grinder with proper guards in a safe location wearing proper face, hand, and body protection.

DSparks can cause fires — keep flammables away.

MOVING PARTS can cause injury.

DKeep away from moving parts.

DKeep away from pinch points such as drive rolls.

OVERUSE can cause OVERHEATING.

DAllow cooling period; follow rated duty cycle.

DReduce current or reduce duty cycle before starting to weld again.

DDo not block or filter airflow to unit.

STATIC (ESD) can damage PC boards.

DPut on grounded wrist strap BEFORE handling boards or parts.

DUse proper static-proof bags and boxes to store, move, or ship PC boards.

TILTING OF TRAILER can cause injury.

DUse tongue jack or blocks to support weight.

DProperly install welding generator onto trailer according to instructions supplied with trailer.

READ INSTRUCTIONS.

DRead Owner’s Manual before using or servic- ing unit.

DUse only genuine replacement parts from the manufacturer.

DPerform engine and air compressor mainte- nance and service according to this manual and the engine/air compressor (if applicable) manuals.

OM-4429 Page 4

Image 8
Contents Processes DescriptionFile Engine Drive Visit our website at OM-44292216 138H 2007−05From Miller to You Table of Contents − Maintenance & Troubleshooting Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous Buildup of GAS can injure or killARC Rays can burn eyes and skin Welding can cause fire or explosionEngine Hazards Compressed Air HazardsWelding Wire can cause injury HOT Parts can cause burns and injuryFire or Explosion hazard Falling Unit can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer Indique des instructions spécifiquesDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peu DES Organes Mobiles peuvent pro voquer des blessuresRisque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures LE Surchauffement peut endom- mager le moteur électrique DES Organes Mobiles peuvent provoquer des blessuresLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutProposition californienne 65 Avertissements Principales normes de sécuritéInformation EMF En ce qui concerne les implants médicauxStd − Definitions− 50 h Std Manufacturer’s Rating Labels CC ModelsSymbols And Definitions Some symbols are found only on CE productsDimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Volt-Ampere Curves For CC Models VoltsStick Mode MIG ModeTIG Mode Volt-Ampere Curves For CC/CV Models100% Duty Cycle At 400 Amperes Fuel ConsumptionDuty Cycle And Overheating AC Generator Power Curve Optional Three-Phase Generator Curves12 kVA/kW Single-Phase AC Output No Weld Load 20 kVA/kW Three-Phase AC Output No Weld Load− Installation Installing Welding GeneratorLocation/Airflow Clearance Grounding1Using Lifting Eye Mounting Welding Generator Installing Exhaust Pipe Stop engine and let coolActivating The Dry Charge Battery If Applicable Connecting The BatteryCoolant Recovery Tank Engine Prestart ChecksFuel OilConnecting To Weld Output Terminals Stick and TIG WeldingMIG and Fcaw Welding Stop engineConnecting to Weld Selecting Weld Cable Sizes150 ft 200 ft 250 ft 350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 mConnecting To Remote 14 Receptacle RC14 On CC/CV Models SocketOM-4429 − Operating Welding Generator − CC Models Front Panel Controls For CC Models See SectionEngine Starting Controls To StartEngine Gauges And Meters Weld ControlsExample Combination Remote Amperage Control Stick Remote Amperage Control On CC Models OptionalWeld Control/Arc Condition Information Label OM-4429 − Operating Welding Generator − CC/CV Models Front Panel Controls For CC/CV Models See SectionVoltage/Amperage Adjust Switch And Remote 14 Receptacle 14 AC/DC Voltmeter OptionalProcess/Contactor Switch On CC/CV Models Process/Contactor Switch SettingsRemote Voltage/Amperage Control On CC/CV Models Optional Example Combination Remote Amperage Control TIG− Operating Auxiliary Equipment Volt And 240 Volt ReceptaclesAt least once a month, run en If a SupplementaryClose panel opening if no connections are made to generator Three-Phase Power ConnectionRear Of Panel Supplementary Protector CB2 Supplementary Protector CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 − Maintenance & Troubleshooting Maintenance LabelRoutine Maintenance Servicing Air Cleaner To clean air filterInspecting And Cleaning Optional Spark Arrestor Muffler Checking Generator BrushesTo replace primary fuel filter Servicing Fuel And Lubrication SystemsTo change oil and filter Overload Protection Troubleshooting Welding − CC ModelsWelding − CC/CV Models Engine Standard Generator PowerOptional Three-Phase Generator Power CC/CV Models Only Check engine wiring harness plug connections Gine Control switch S1Factory Authorized Service Agent Engine cranks but does not start Check fuel levelStart Your Professional Welding Career Now − Electrical Diagrams Circuit Diagram For CC Welding Generator223 525-B Circuit Diagram For CC/CV Welding Generator 223 524-B Welding Generator − RUN-IN ProcedureWetstacking From flammables Run-In Procedure Using Load BankKeep exhaust and pipe away Run-In Procedure Using Resistance Grid Specifications section in thisJust generator A/V control so Manual− Generator Power Guidelines Selecting EquipmentGrounding Generator To Truck Or Trailer Frame Electrically Bond GeneratorGrounding When Supplying Building Systems How Much Power Does Equipment Require?Use ground device as stated in electrical codes Amperes x Volts = WattsApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible 123 116 CV 112 − Parts List114 −7 115 CV 2831 124 88 −6 6059 58 Dia Part Description Quantity Dia Part Description Quantity Mkgs Figures 13-2 111123 212 Control Box Assembly − CC Models Control Box Assembly − CC Models -1Item Engine ControllerControl Box Assembly − CC/CV Models 134 Panel, Front w/Components − CC Models 3634208278 Panel, Front w/Components − CC/CV Models Panel, Front w/Components − CC/CV Models -1ItemCB1 201 Supplementary PROTECTOR, man reset 2P 20 A, 250VAC Hardware is common 32 31 30053 BEARING, Ball Rdl Sgl Row 1.370 X 2.830 X Main Rectifier Assembly Wiring Harnesses 215207 Support ServiceYour distributor also gives To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s