Miller Electric Big Blue 600 X manual Engine Prestart Checks, Coolant Recovery Tank, Fuel, Oil

Page 29

5-7. Engine Prestart Checks

Check radiator coolant level when fluid is low in recovery tank.

Full

Capacity:

404.22 Engine: 9.5 qt (9.01L)

Full

Diesel

Full

Coolant Recovery Tank

Hot Full

Cold Full

803 603

.Check all engine fluids daily.

Engine must be cold and on a level surface. Unit is shipped with 20W break-in oil.

Automatic shutdown system stops engine if oil pressure is too low, coolant temperature is too high, or engine overspeeds.

.This unit has a low oil pressure shut- down switch. However, some condi- tions may cause engine damage before the engine shuts down. Check oil level often and do not use the oil pressure shutdown system to monitor oil level.

Follow run-in procedure in engine manual. If unburned fuel and oil collect in exhaust pipe during run-in, see Section 11.

Fuel

NOTICE − Do not use gasoline. Gasoline will damage engine.

The unit is shipped with enough fuel to pre- vent air from entering fuel system. Add fresh diesel fuel before starting (see engine main- tenance label for fuel specifications). Leave filler neck empty to allow room for ex- pansion.

Do not run out of fuel or air will enter fuel sys- tem and cause starting problems. See en- gine manual to bleed air from fuel system.

Oil

After fueling, check oil with unit on level sur- face. If oil is not up to full mark on dipstick, add oil (see maintenance label).

Coolant

Check coolant level in radiator before start- ing unit the first time. If necessary, add cool- ant to radiator until coolant level is at bottom of filler neck.

Check coolant level in recovery tank daily. If necessary, add coolant to recovery tank until coolant level is between Cold Full and Hot Full levels. If recovery tank coolant level was low, also check coolant level in radiator. Add coolant if level is below bottom of radia- tor filler neck.

Unit is shipped with an engine coolant mix- ture of water and ethylene glycol base anti-

freeze rated to −34° F (−37° C). Add anti-

freeze to mixture if using the unit in tempera- tures below −34° F (−37° C).

Keep radiator and air intake clean and free of dirt.

NOTICE − Incorrect engine temperature can damage engine. Do not run engine with- out a properly working thermostat and ra- diator cap.

.To improve cold weather starting:

Use Starting Aid switch (see Section 6-1or 7-1).

Keep battery in good condition. Store battery in warm area.

Use fuel formulated for cold weather (diesel fuel can gel in cold weather). Contact local fuel supplier for fuel in- formation.

Use correct grade oil for cold weather (see Section 9-1).

OM-4429 Page 25

Image 29
Contents Description ProcessesFile Engine Drive Visit our website at OM-44292216 138H 2007−05From Miller to You Table of Contents − Maintenance & Troubleshooting Arc Welding Hazards Symbol UsageElectric Shock can kill HOT Parts can cause severe burnsBuildup of GAS can injure or kill Fumes and Gases can be hazardousARC Rays can burn eyes and skin Welding can cause fire or explosionCompressed Air Hazards Engine HazardsHOT Parts can cause burns and injury Welding Wire can cause injuryFire or Explosion hazard Falling Unit can cause injuryCalifornia Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer Indique des instructions spécifiquesLES Fumées ET LES GAZ peuvent être dangereux DES Pièces Chaudes peuvent provoquer des brûlures gravesLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent pro voquer des blessures ’EXPLOSION DE LA Batterie peuRisque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures DES Organes Mobiles peuvent provoquer des blessures LE Surchauffement peut endom- mager le moteur électriqueLES Fils DE Soudage peuvent provoquer des blessures ’EMPLOI Excessif peutPrincipales normes de sécurité Proposition californienne 65 AvertissementsInformation EMF En ce qui concerne les implants médicauxStd − Definitions− 50 h Std CC Models Manufacturer’s Rating LabelsSome symbols are found only on CE products Symbols And DefinitionsDimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Volts Volt-Ampere Curves For CC ModelsMIG Mode Stick ModeTIG Mode Volt-Ampere Curves For CC/CV Models100% Duty Cycle At 400 Amperes Fuel ConsumptionDuty Cycle And Overheating Optional Three-Phase Generator Curves AC Generator Power Curve12 kVA/kW Single-Phase AC Output No Weld Load 20 kVA/kW Three-Phase AC Output No Weld LoadInstalling Welding Generator − InstallationLocation/Airflow Clearance Grounding1Using Lifting Eye Mounting Welding Generator Stop engine and let cool Installing Exhaust PipeConnecting The Battery Activating The Dry Charge Battery If ApplicableEngine Prestart Checks Coolant Recovery TankFuel OilStick and TIG Welding Connecting To Weld Output TerminalsMIG and Fcaw Welding Stop engineSelecting Weld Cable Sizes Connecting to Weld150 ft 200 ft 250 ft 350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 mSocket Connecting To Remote 14 Receptacle RC14 On CC/CV ModelsOM-4429 Front Panel Controls For CC Models See Section − Operating Welding Generator − CC ModelsTo Start Engine Starting ControlsEngine Gauges And Meters Weld ControlsExample Combination Remote Amperage Control Stick Remote Amperage Control On CC Models OptionalWeld Control/Arc Condition Information Label OM-4429 Front Panel Controls For CC/CV Models See Section − Operating Welding Generator − CC/CV Models14 AC/DC Voltmeter Optional Voltage/Amperage Adjust Switch And Remote 14 ReceptacleProcess/Contactor Switch Settings Process/Contactor Switch On CC/CV ModelsExample Combination Remote Amperage Control TIG Remote Voltage/Amperage Control On CC/CV Models OptionalVolt And 240 Volt Receptacles − Operating Auxiliary EquipmentAt least once a month, run en If a SupplementaryClose panel opening if no connections are made to generator Three-Phase Power ConnectionRear Of Panel Supplementary Protector CB2 Supplementary Protector CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 Maintenance Label − Maintenance & TroubleshootingRoutine Maintenance To clean air filter Servicing Air CleanerChecking Generator Brushes Inspecting And Cleaning Optional Spark Arrestor MufflerTo replace primary fuel filter Servicing Fuel And Lubrication SystemsTo change oil and filter Overload Protection Welding − CC Models TroubleshootingWelding − CC/CV Models Engine Standard Generator PowerOptional Three-Phase Generator Power CC/CV Models Only Gine Control switch S1 Check engine wiring harness plug connectionsFactory Authorized Service Agent Engine cranks but does not start Check fuel levelStart Your Professional Welding Career Now Circuit Diagram For CC Welding Generator − Electrical Diagrams223 525-B Circuit Diagram For CC/CV Welding Generator 223 524-B Welding Generator − RUN-IN ProcedureWetstacking From flammables Run-In Procedure Using Load BankKeep exhaust and pipe away Specifications section in this Run-In Procedure Using Resistance GridJust generator A/V control so ManualSelecting Equipment − Generator Power GuidelinesGrounding Generator To Truck Or Trailer Frame Electrically Bond GeneratorHow Much Power Does Equipment Require? Grounding When Supplying Building SystemsUse ground device as stated in electrical codes Amperes x Volts = WattsApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP x 1000 / Volts = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible 123 116 CV 112 − Parts List114 −7 115 CV 2831 124 88 −6 6059 58 Dia Part Description Quantity Dia Part Description Quantity Mkgs 111 Figures 13-2123 212 Control Box Assembly − CC Models Engine Controller Control Box Assembly − CC Models -1ItemControl Box Assembly − CC/CV Models 134 3634 Panel, Front w/Components − CC Models208278 Panel, Front w/Components − CC/CV Models -1Item Panel, Front w/Components − CC/CV ModelsCB1 201 Supplementary PROTECTOR, man reset 2P 20 A, 250VAC 32 31 30 Hardware is common053 BEARING, Ball Rdl Sgl Row 1.370 X 2.830 X Main Rectifier Assembly Wiring Harnesses 215207 Support ServiceYour distributor also gives Miller Electric Mfg. Co To locate a Distributor or Service Agency visitFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s