9-3. Servicing Air Cleaner

! Stop engine.

 

 

 

 

NOTICE − Do not run engine without air

1

2

3

4

cleaner or with dirty element. Engine

damage caused by using a damaged ele-

 

 

 

 

 

 

 

 

ment is not covered by the warranty.

 

 

 

 

. The air cleaner primary element can

 

 

 

 

be cleaned but the dirt holding capac-

 

 

 

 

ity of the filter is reduced with each

 

 

 

 

cleaning. The chance of dirt reaching

 

 

 

 

the clean side of the filter while clean-

 

 

 

 

ing and the possibility of filter damage

 

Optional

 

 

makes cleaning a risk. Consider the

 

 

 

risk of unwarrantable equipment

 

 

 

 

 

 

 

5

damage when determining whether

 

 

 

 

to clean or replace the primary ele-

ment.

If you decide to clean the primary ele- ment, we strongly recommend instal- ling an optional safety element to pro- vide additional engine protection. Never clean a safety element. Re- place the safety element after servic- ing the primary element three times.

Keep nozzle 2 in (51 mm) from element.

Clean or replace primary element if dirty (see note above before cleaning). Re- place primary element if damaged. Re- place primary element yearly or after six cleanings.

 

 

1

Housing

 

 

2

Safety Element (Optional)

 

 

3

Primary Element

 

 

4

Dust Cap

 

 

5

Dust Ejector

 

 

To clean air filter:

 

 

Wipe off cap and housing. Remove cap

 

 

and dump out dust. Remove element(s).

 

 

Wipe dust from inside cap and housing

 

 

with damp cloth. Reinstall safety element

Blow

Inspect

(if present). Reinstall cap.

 

 

NOTICE − Do not clean housing with air hose.

Clean primary element with compressed air only.

Air pressure must not exceed 100 psi (690 kPa). Use 1/8 in (3 mm) nozzle and keep nozzle at least 2 in (51 mm) from inside of element. Replace primary ele- ment if it has holes or damaged gaskets.

Reinstall primary element and cap (dust ejector down).

aircleaner1 9/00 − ST-153 929-B / ST-153 585 / Ref. S-0698-B / Ref. 215 158

OM-4429 Page 43

Image 47
Contents Visit our website at OM-44292216 138H 2007−05 ProcessesDescription File Engine DriveFrom Miller to You Table of Contents − Maintenance & Troubleshooting HOT Parts can cause severe burns Symbol UsageArc Welding Hazards Electric Shock can killWelding can cause fire or explosion Fumes and Gases can be hazardousBuildup of GAS can injure or kill ARC Rays can burn eyes and skinCompressed Air Hazards Engine HazardsFalling Unit can cause injury Welding Wire can cause injuryHOT Parts can cause burns and injury Fire or Explosion hazardRadiation can cause interference Principal Safety StandardsCalifornia Proposition 65 Warnings EMF InformationIndique des instructions spécifiques Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation UN Choc Électrique peut tuerLE Bruit peut affecter l’ouïe DES Pièces Chaudes peuvent provoquer des brûlures gravesLES Fumées ET LES GAZ peuvent être dangereux LE Soudage peut provoquer un in cendie ou une explosionDES Organes Mobiles peuvent pro voquer des blessures ’EXPLOSION DE LA Batterie peuRisque D’INCENDIE OU D’EXPLO- Sion LA Chaleur DU Moteur peut pro- voquer un incendie’AIR Comprimé peut provoquer des blessures ’EMPLOI Excessif peut LE Surchauffement peut endom- mager le moteur électriqueDES Organes Mobiles peuvent provoquer des blessures LES Fils DE Soudage peuvent provoquer des blessuresEn ce qui concerne les implants médicaux Proposition californienne 65 AvertissementsPrincipales normes de sécurité Information EMFStd − Definitions− 50 h Std CC Models Manufacturer’s Rating LabelsSome symbols are found only on CE products Symbols And DefinitionsDimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Volts Volt-Ampere Curves For CC ModelsVolt-Ampere Curves For CC/CV Models Stick ModeMIG Mode TIG Mode100% Duty Cycle At 400 Amperes Fuel ConsumptionDuty Cycle And Overheating 20 kVA/kW Three-Phase AC Output No Weld Load AC Generator Power CurveOptional Three-Phase Generator Curves 12 kVA/kW Single-Phase AC Output No Weld LoadGrounding1 − InstallationInstalling Welding Generator Location/Airflow ClearanceUsing Lifting Eye Mounting Welding Generator Stop engine and let cool Installing Exhaust PipeConnecting The Battery Activating The Dry Charge Battery If ApplicableOil Coolant Recovery TankEngine Prestart Checks FuelStop engine Connecting To Weld Output TerminalsStick and TIG Welding MIG and Fcaw Welding350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 m Connecting to WeldSelecting Weld Cable Sizes 150 ft 200 ft 250 ftSocket Connecting To Remote 14 Receptacle RC14 On CC/CV ModelsOM-4429 Front Panel Controls For CC Models See Section − Operating Welding Generator − CC ModelsWeld Controls Engine Starting ControlsTo Start Engine Gauges And MetersExample Combination Remote Amperage Control Stick Remote Amperage Control On CC Models OptionalWeld Control/Arc Condition Information Label OM-4429 Front Panel Controls For CC/CV Models See Section − Operating Welding Generator − CC/CV Models14 AC/DC Voltmeter Optional Voltage/Amperage Adjust Switch And Remote 14 ReceptacleProcess/Contactor Switch Settings Process/Contactor Switch On CC/CV ModelsExample Combination Remote Amperage Control TIG Remote Voltage/Amperage Control On CC/CV Models OptionalIf a Supplementary − Operating Auxiliary EquipmentVolt And 240 Volt Receptacles At least once a month, run enClose panel opening if no connections are made to generator Three-Phase Power ConnectionRear Of Panel Supplementary Protector CB2 Supplementary Protector CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 Maintenance Label − Maintenance & TroubleshootingRoutine Maintenance To clean air filter Servicing Air CleanerChecking Generator Brushes Inspecting And Cleaning Optional Spark Arrestor MufflerTo replace primary fuel filter Servicing Fuel And Lubrication SystemsTo change oil and filter Overload Protection Welding − CC Models TroubleshootingWelding − CC/CV Models Engine Standard Generator PowerOptional Three-Phase Generator Power CC/CV Models Only Engine cranks but does not start Check fuel level Check engine wiring harness plug connectionsGine Control switch S1 Factory Authorized Service AgentStart Your Professional Welding Career Now Circuit Diagram For CC Welding Generator − Electrical Diagrams223 525-B Circuit Diagram For CC/CV Welding Generator 223 524-B Welding Generator − RUN-IN ProcedureWetstacking From flammables Run-In Procedure Using Load BankKeep exhaust and pipe away Manual Run-In Procedure Using Resistance GridSpecifications section in this Just generator A/V control soElectrically Bond Generator − Generator Power GuidelinesSelecting Equipment Grounding Generator To Truck Or Trailer FrameAmperes x Volts = Watts Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Use ground device as stated in electrical codesFarm/Home Equipment Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Industrial Motors Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentKVA/HP x HP x 1000 / Volts = Starting Amperage Power Required To Start MotorHow Much Power Can Generator Supply? Single-Phase Induction Motor Starting RequirementsTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible 123 116 CV 112 − Parts List114 −7 115 CV 2831 124 88 −6 6059 58 Dia Part Description Quantity Dia Part Description Quantity Mkgs 111 Figures 13-2123 212 Control Box Assembly − CC Models Engine Controller Control Box Assembly − CC Models -1ItemControl Box Assembly − CC/CV Models 134 3634 Panel, Front w/Components − CC Models208278 Panel, Front w/Components − CC/CV Models -1Item Panel, Front w/Components − CC/CV ModelsCB1 201 Supplementary PROTECTOR, man reset 2P 20 A, 250VAC 32 31 30 Hardware is common053 BEARING, Ball Rdl Sgl Row 1.370 X 2.830 X Main Rectifier Assembly Wiring Harnesses 215207 Support ServiceYour distributor also gives Your distributor and/or equipment manufacturer’s To locate a Distributor or Service Agency visitMiller Electric Mfg. Co For assistance in filing or settling claims, contact