Miller Electric Blue Star 3500 manual Symbol Usage, Arc Welding Hazards

Page 5

SECTION 1 − SAFETY PRECAUTIONS − READ BEFORE USING

rom _nd_8/03

YWarning: Protect yourself and others from injury — read and follow these precautions.

1-1. Symbol Usage

Means Warning! Watch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols.

YMarks a special safety message.

.Means “Note”; not safety related.

This group of symbols means Warning! Watch Out! possible ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards. Consult symbols and related instructions below for necessary actions to avoid the hazards.

1-2. Arc Welding Hazards

YThe symbols shown below are used throughout this manual to call attention to and identify possible hazards. When you see the symbol, watch out, and follow the related instructions to avoid the hazard. The safety information given below is only a summary of the more complete safety information found in the Safety Stan- dards listed in Section 1-7. Read and follow all Safety Standards.

DUse only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual.

DWear a safety harness if working above floor level.

DKeep all panels and covers securely in place.

DClamp work cable with good metal-to-metal contact to workpiece or work- table as near the weld as practical.

YOnly qualified persons should install, operate, maintain, and re- pair this unit.

YDuring operation, keep everybody, especially children, away.

DInsulate work clamp when not connected to workpiece to prevent contact with any metal object.

DDo not connect more than one electrode or work cable to any single weld output terminal.

ELECTRIC SHOCK can kill.

Touching live electrical parts can cause fatal shocks or severe burns. The electrode and work circuit is electrically live whenever the output is on. The input power circuit and

machine internal circuits are also live when power is on. In semiautomatic or automatic wire welding, the wire, wire reel, drive roll housing, and all metal parts touching the welding wire are electrically live. Incorrectly installed or improperly grounded equipment is a hazard.

DDo not touch live electrical parts.

DWear dry, hole-free insulating gloves and body protection.

DInsulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work or ground.

DDo not use AC output in damp areas, if movement is confined, or if there is a danger of falling.

DUse AC output ONLY if required for the welding process.

DIf AC output is required, use remote output control if present on unit.

DAdditional safety precautions are required when any of the following electri- cally hazardous conditions are present: in damp locations or while wearing wet clothing; on metal structures such as floors, gratings, or scaffolds; when in cramped positions such as sitting, kneeling, or lying; or when there is a high risk of unavoidable or accidental contact with the workpiece or ground. For these conditions, use the following equipment in order present- ed: 1) a semiautomatic DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit voltage. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone!

DDisconnect input power or stop engine before installing or servicing this equipment. Lockout/tagout input power according to OSHA 29 CFR 1910.147 (see Safety Standards).

DProperly install and ground this equipment according to its Owner’s Manual and national, state, and local codes.

DAlways verify the supply ground — check and be sure that input power cord ground wire is properly connected to ground terminal in disconnect box or that cord plug is connected to a properly grounded receptacle outlet.

DWhen making input connections, attach proper grounding conductor first − double-check connections.

DFrequently inspect input power cord for damage or bare wiring — replace cord immediately if damaged — bare wiring can kill.

DTurn off all equipment when not in use.

DDo not use worn, damaged, undersized, or poorly spliced cables.

DDo not drape cables over your body.

DIf earth grounding of the workpiece is required, ground it directly with a sep- arate cable.

DDo not touch electrode if you are in contact with the work, ground, or anoth- er electrode from a different machine.

SIGNIFICANT DC VOLTAGE exists in inverters after stop- ping engine.

DStop engine on inverter and discharge input capacitors according to instructions in Maintenance Section before touching any parts.

FUMES AND GASES can be hazardous.

Welding produces fumes and gases. Breathing these fumes and gases can be hazardous to your health.

DKeep your head out of the fumes. Do not breathe the fumes.

DIf inside, ventilate the area and/or use exhaust at the arc to remove welding fumes and gases.

DIf ventilation is poor, use an approved air-supplied respirator.

DRead the Material Safety Data Sheets (MSDSs) and the manufacturer’s instructions for metals, consumables, coatings, cleaners, and degreasers.

DWork in a confined space only if it is well ventilated, or while wearing an air- supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and lower the oxygen level causing injury or death. Be sure the breathing air is safe.

DDo not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form highly toxic and irritating gases.

DDo not weld on coated metals, such as galvanized, lead, or cadmium plated steel, unless the coating is removed from the weld area, the area is well ventilated, and if necessary, while wearing an air-supplied respirator. The coatings and any metals containing these elements can give off toxic fumes if welded.

BUILDUP OF GAS can injure or kill.

D Shut off shielding gas supply when not in use.

DAlways ventilate confined spaces or use approved air-supplied respirator.

ARC RAYS can burn eyes and skin.

Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld.

DWear a welding helmet fitted with a proper shade of filter to protect your face and eyes from arc rays and sparks when welding or watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).

DWear approved safety glasses with side shields under your helmet.

DUse protective screens or barriers to protect others from flash and glare; warn others not to watch the arc.

DWear protective clothing made from durable, flame-resistant material (wool and leather) and foot protection.

Return To Table Of Contents

OM-498 Page 1

Image 5
Contents Description OM-498Processes From Miller to You Table of Contents Page Arc Welding Hazards Symbol UsageEngine Hazards Compressed Air Hazards California Proposition 65 Warnings Principal Safety StandardsEMF Information Radiation can cause interference− Consignes DE Sécurité − Lire Avant Utilisation Signification des symbolesUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxDES Particules Volantes peuvent blesser les yeux LE Soudage peut provoquer un in- cendie ou une explosionDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïeDES Organes Mobiles peuvent provoquer des blessures ’EXPLOSION DE LA Batterie peutLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoque r des blessuresInformation sur les champs électromagnétiques Principales normes de sécuritéSymbol Definitions − SpecificationsWeld, Power, And Engine Specifications − DefinitionsFuel Consumption Kohler-Powered Units Dimensions, Weights, And Operating AnglesDimensions Weight Kohler-Powered UnitsExceeding duty cycle can damage unit and void warranty Fuel Consumption Honda-Powered UnitsDuty Cycle 100% Duty Cycle at 80 Amperes CC/DCVolt-Ampere Curves Generator Power CurveGrounding Generator To Truck Or Trailer Frame − InstallationInstalling Welding Generator Use ground device as stated in electrical codes Grounding Generator When Supplying Building SystemsConnecting The Battery Honda Electric-Start Models Only Engine Prestart Checks Honda-Powered Units+ − OilSelecting Weld Cable Sizes Connecting To Weld Output Terminals− Operating the Welding Generator Controls Kohler-Powered Units60 Hz Choke Control LeverRecoil-Start 2Electric-Start Controls Honda-Powered Units See SectionWork like a Pro Description Of Controls Honda-Powered Units See Section120 V x 10 a + 240 V x 9 a = 3.5 kVA/ KW OM-498 Generator Power Panel 495 218 USA− Operating Auxiliary Equipment Generator Power Panel 495 Optional Generator Power PanelsCanada South Africa South America Australia Europe AsiaIt exceeds 3500W Generator Power Panel RatingsWire Load Plug Wired For 120/240Plex receptacle shares a load with One half of the 240 V receptacle− Maintenance Overload Protection Honda-Powered Units Only Maintenance LabelWeld/Power Speed Adjustment Adjusting Engine Speed Kohler-Powered UnitsTop View Idle Speed Adjustment Stop engine. Close fuel valve Top ViewThrottle Control Lever Adjustment Screw Adjusting Engine Speed Honda-Powered UnitsStop engine. Close fuel valve Tools Needed 3/8Troubleshooting − TroubleshootingGenerator Power WeldingViscosity oil for operating temperature Check battery voltage Honda electric-start models onlyEngine Make starting difficultCircuit Diagram For Welding Generator − Electrical DiagramsWiring Diagram For Generator Power Panels 1 Wiring Diagram For Generator Power Panels 2 OM-491 − Generator Power GuidelinesSelecting Equipment How Much Power Does Equipment Require? Grounding When Supplying Building SystemsEarth ground if supplying Volts 115 Amps Resistive LoadApproximate Power Requirements For Farm/Home Equipment Approximate Power Requirements For Industrial MotorsIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentHow Much Power Can Generator Supply? Power Required To Start MotorSingle-Phase Induction Motor Starting Requirements KVA/HP x HP xTypical Connections To Supply Standby Power Current Load Watts Amperes Selecting Extension Cord Use Shortest Cord Possible− Stick Welding Smaw Guidelines Stick Welding ProcedureWeld current starts when electrode touches work- piece Striking an Arc − Tapping Technique Electrode and Amperage Selection ChartStriking an Arc − Scratch Start Technique Good Weld Bead Characteristics Poor Weld Bead CharacteristicsPositioning Electrode Holder 10-30 9090 End View of Work AngleElectrode Movement During Welding Conditions That Affect Weld Bead ShapeLap Joint Butt JointsTee Joint 16 in 1.6 mm Tack WeldsTroubleshooting − Excessive Spatter Troubleshooting − PorosityWeld Test Possible Causes Corrective ActionsTroubleshooting − Excessive Penetration Troubleshooting − Incomplete FusionTroubleshooting − Lack Of Penetration Troubleshooting − Distortion Troubleshooting − Burn-ThroughTroubleshooting − Waviness Of Bead 31−Fig − Parts ListDia Part Generator Power Panel 495 South Africa Australia Generator Power Panel 495 Generator Power Panel 495 315 USACanada Europe AmericaGenerator Power Panel 495 279 Canada Generator Power Panel 495 218 USAGenerator Power Panel 495 253 South Africa Generator Power Panel 495 289 AustraliaWork like a Pro Page TM-188 304 Invision 354MP Material Thickness Reference ChartSupport ServiceYour distributor also gives For assistance in filing or settling claims, contact Miller Electric Mfg. CoYour distributor and/or equipment manufacturer’s Transportation Department