. A complete Parts List is available at www.MillerWelds.com
8-7. Overload Protection (Robin-Powered Units)
! Stop engine. Disconnect negative (−) battery cable.
2 | 1 | . Fuse F6 located in | |
harness behind left | |||
|
| ||
|
| side door. | |
|
| 3 |
. Fuses F1, F2 located on bracket behind left side panel.
Tools Needed:
1 Fuse F1 (See Section 11-1)
F1 protects the weld excitation winding from overload. If F1 opens, weld output stops or is low.
2 Fuse F2 (See Section
F2 protects the generator power excitation winding from overload. If F2 opens, generator power output stops or is low.
3 Fuse F6 (See Section
F6 protects the engine wiring sys- tem from overload. If F6 opens, engine will not crank.
Replace any open fuses. Reinstall cover before operating.
NOTICE − If a fuse opens, it usually indicates a more serious problem exists. Contact a Factory Autho- rized Service Agent.
3/8 in
803
Notes
MATERIAL THICKNESS REFERENCE CHART
24 Gauge (.025 in)
22 Gauge (.031 in)
20 Gauge (.037 in)
18 Gauge (.050 in)
16 Gauge (.063 in)
14 Gauge (.078 in) 1/8 in (.125 in)
3/16 in (.188 in)
1/4 in (.25 in)
5/16 in (.313 in)
3/8 in (.375 in)
1/2 in (.5 in)