Miller Electric Big Blue 400 KX California Proposition 65 Warnings, Principal Safety Standards

Page 10

READ INSTRUCTIONS.

D Use only genuine MILLER/Hobart replacement parts.

DPerform engine and air compressor (if applicable) maintenance and service according to this manual and the engine/air compressor (if applicable) manu- als.

H.F. RADIATION can cause interference.

DHigh-frequency (H.F.) can interfere with radio naviga- tion, safety services, computers, and communica- tions equipment.

DHave only qualified persons familiar with electronic equipment perform this installation.

DThe user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.

DIf notified by the FCC about interference, stop using the equipment at once.

DHave the installation regularly checked and maintained.

DKeep high-frequency source doors and panels tightly shut, keep spark gaps at correct setting, and use grounding and shielding to minimize the possibility of interference.

ARC WELDING can cause interference.

DElectromagnetic energy can interfere with sensitive electronic equipment such as microprocessors, computers, and computer-driven equipment such as robots.

DBe sure all equipment in the welding area is electro- magnetically compatible.

DTo reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.

DLocate welding operation 100 meters from any sensitive electronic equipment.

DBe sure this welding machine is installed and grounded according to this manual.

DIf interference still occurs, the user must take extra measures such as moving the welding machine, using shielded cables, using line filters, or shielding the work area.

1-6. California Proposition 65 Warnings

YWelding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)

YBattery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

For Gasoline Engines:

YEngine exhaust contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

For Diesel Engines:

YDiesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.

1-7. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers and Piping, American Welding Society Standard AWS F4.1, from Global Engineering Documents (phone: 1-877-413-5184, website: www.global.ihs.com).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269-9101 (phone: 617-770-3000, website: www.nfpa.org and www. sparky.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1735 Jefferson Davis Highway, Suite 1004, Arlington, VA 22202-4102 (phone: 703-412-0900, website: www.cganet.com).

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale Bou-

levard, Rexdale, Ontario, Canada M9W 1R3 (phone: 800-463-6727 or

in Toronto 416-747-4044, website: www.csa-international.org).

Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 11 West 42nd Street, New York, NY 10036–8002 (phone: 212-642-4900, website: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269-9101 (phone: 617-770-3000, website: www.nfpa.org.

OSHA, Occupational Safety and Health Standards for General Indus- try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super- intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there are 10 Regional Offices—phone for Region 5, Chicago, is 312-353-2220, website: www.osha.gov).

1-8. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

OM-4423 Page 4

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from operator as practical.

5.Connect work clamp to workpiece as close to the weld as possible.

About Pacemakers:

Pacemaker wearers consult your doctor before welding or going near welding operations. If cleared by your doctor, then following the above procedures is recommended.

Image 10
Contents Description OM-4423 215 178NProcesses File Engine DriveFrom Miller to You Table of Contents − Maintenance & Troubleshooting 8-1. Routine Maintenance Standards DirectivesDecrot6/05 Sound Level Information Decrotsound1/05Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards EMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings Radiation can cause interferenceUN Choc Électrique peut tuer Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation LES Fumées ET LES GAZ peuvent être dangereuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux LE Bruit peut affecter l’ouïeLE Surchauffement peut endom- mager le moteur électrique ’AIR Comprimé peut provoquer des blessures’EMPLOI Excessif peut LES Étincelles Volantes risquent de provoquer des blessuresPour les moteurs diesel LE Soudage À L’ARC risque de provoquer des interférencesPour les moteurs à essence Boulevard, Rexdale, Ontario, Canada M9W 1R3 téléphone− 50 h Std − DefinitionsStd Manufacturer’s Rating Label Symbols And Definitions Weld, Power, And Engine Specifications − SpecificationsDimensions, Weights, And Operating Angles TIG Mode Stick ModeMIG Mode Volt-Ampere CurvesFuel Consumption Curve shows typical fuel use under weld or power loadsExceeding duty cycle can damage unit and void warranty Duty Cycle And OverheatingAC Generator Power Curve Ac power curve shows the gen- erator power in amperes− Installation Installing Welding GeneratorMounting Welding Generator Tools Needed 1/2 Installing Exhaust PipeStop engine and let cool Do not overfill battery cells Activating The Dry Charge Battery If ApplicableConnecting The Battery Connect Negative − Cable LastFuel Do not use gasoline. Gasoline will damage engine Coolant Recovery TankEngine Prestart Checks OilMIG and Fcaw Welding Connecting To Weld Output TerminalsStick and TIG Welding Stop engine350 ft 400 ft 45 m 60 m 70 m 90 m 105 m 120 m Selecting Weld Cable Sizes150 ft 200 ft 250 ft Stop engine beforeConnecting To Remote 14 Receptacle RC14 SocketFront Panel Controls See Section StopDescription Of Front Panel Controls See Section Process/Contactor Switch On CC/CV Models Process/Contactor Switch SettingsDo not Strike Like a Match Lift-ArcStart ProcedureLift-Arc Start Method Touch Lift-Arc t TIGRemote Voltage/Amperage Control − Operating Auxiliary Equipment Volt Receptacles− Maintenance & Troubleshooting Routine MaintenanceMaintenance Label To clean air filter Servicing Air CleanerBy the warranty Do not clean housing with air hoseStop engine and let cool. Reinstall cleanout plug Inspecting And Cleaning Spark Arrestor MufflerServicing Engine Cooling System Adjusting Engine Speed On Standard Models MaximumTo change oil and filter Servicing Fuel And Lubrication SystemsStop engine and let cool After servicing, start engine To replace primary canister fuel filterPress button to reset breaker Overload ProtectionChecking Generator Brushes Replace Damaged BrushesHelp 20 Display Voltmeter/Ammeter Help DisplaysHelp 25 Display Standard Generator Power TroubleshootingWelding Engine Check for obstructed throttle solenoid − Electrical Diagrams Circuit Diagram For Welding Generator221 499-B Wetstacking − RUN-IN ProcedureWelding Generator Stop engine Do not touch hot exhaust Run-In Procedure Using Load BankProcedure at less than From flammables Do not PerformFrom flammables Run-In Procedure Using Resistance GridBank/grid Do not perform run-inSelecting Equipment − Generator Power GuidelinesGrounding Generator To Truck Or Trailer Frame Earth ground if supplying Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Amperes x Volts = WattsIndustrial Motors Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsSingle-Phase Induction Motor Starting Requirements Power Required To Start MotorHow Much Power Can Generator Supply? KVA/HP x HP x 1000 = Starting AmperageTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes− Parts List 103 − −5 104 − −3 96− −2 102 101 10071− −4 3031 5756Dia Part Description Quantity Mkgs Dia Part Description Quantity 213600 Panel, Front w/Components Panel, Front w/Components -1ItemFUEL/HM Control Panel Generator Generator -1ItemRectifier Assembly Wiring Harnesses Your distributor also gives ServiceSupport For assistance in filing or settling claims, contact To locate a Distributor or Service Agency visitMiller Electric Mfg. Co Your distributor and/or equipment manufacturer’s