Chauvet 1-TRI IP Setting Description, When R, G, and B are 255, the output will be at its maximum

Page 15

Operation

Color Adjustment

Dimmer Curves

Control Panel Lock

Program Upload

Continued from previous page

The COLOR setting determines how the COLORado™ 1-Tri IP displays the white color when the Red, Green, and Blue faders are all at the “255” value.

1)Go to SET > Color.

2)Select OFF, RGBW, or UC.

Setting

Description

OFF

When R, G, and B are “255,” the output will be at its maximum.

RGBW

When R, G, and B are “255,” CAL2 will determine the output.

UC

When R, G, and B are “255,” the output will match that of fixtures from

previous generations.

 

This setting determines how the output of the COLORado™ 1-Tri IP follows the position of the Dimmer fader, as well as the Red, Green, and Blue faders.

1)Go to SET > Dim.

2)Select a dimmer curve (Off, Dim1, Dim2, Dim3, or Dim4).

Setting

Description

OFF

The output is proportional to the faders’ position (linear)

Dim1

The output is not proportional (fastest)

Dim2

The output is not proportional (fast)

Dim3

The output is not proportional (slow)

Dim4

The output is not proportional (slowest)

This setting allows the user to activate or disable the control panel lock, which keeps non-authorized personnel from changing the fixture’s settings.

1)Go to KEY.

2)Select On/ Off.

When the control panel lock is active, the fixture will prompt the user to enter the password after 30 seconds of control panel inactivity or after turning on the fixture.

After being prompted to enter the password:

1)Press <UP>, <DOWN>, <UP>, <DOWN>, and <ENTER>.

This option allows the user to copy the custom programs of one COLORado™ 1-Tri IP fixture onto other COLORado™ 1-Tri IP fixtures by using the Master/Slave method.

1)Configure and connect the fixtures in a Master/Slave arrangement, where the master unit has the custom programs you want to transfer onto the slave units.

2)At the master unit, go to SET > UPLD.

3)When prompted, enter the master access password as shown in Control Panel Lock.

4)Wait for the upload process to finish before disconnecting the fixtures.

During and after the upload, the master and slave units will visually indicate the status of the process, as follows:

Color

Meaning

Yellow

The upload process is running

Red

The upload failed due to an error

Green

The upload finished successfully

Continues on the next page

COLORado™ 1-Tri IP User Manual Rev. 01c

-11-

Image 15
Contents Page Author Editor Manager PD Manager Copyright 2010 CHAUVET. All rights reservedTable of Contents Table of Contents What is Included Before You BeginIcon Meaning Expected LED Lifespan Safety NotesProduct Description FeaturesAdditional Features Options IntroductionBlue DMX Channel FunctionRed GreenProduct Overview Connection Wire US Wire Europe IP66 Pin Screw Color SetupAC Power AC Plug Power Linking Fuse ReplacementDMX Linking ID AddressingDMX Modes Master/Slave Connectivity Orientation Rigging MountingButton Function OperationControl Options Programming DMX Personality DMX Control Without ID AddressingFrom previous Upload failed due to an error Setting DescriptionWhen R, G, and B are 255, the output will be at its maximum When R, G, and B are 255, CAL2 will determine the outputGo to SET Rest Reset Whites Setting White CalibrationTour Notes Menu Map DMX Values Tour ARC1 + DAR1 + S ~100% Channel Function Value Percent/Setting HueTechnical Information General MaintenanceSymptom Causes Actions Troubleshooting GuideExploded View Photometrics Contact Us World Headquarters ClaimsTechnical Specifications Chauvet