Chauvet 1-TRI IP user manual From previous

Page 14

Operation

Continued from previous page

DMX Control With ID Addressing

Static Color

Auto Programs

Edit Customs

Master/Slave

In this mode, the fixtures with the same DMX starting address will respond to the DMX controller based on the fixture’s individual ID address setting. If the user selects ID address “0”, all the fixtures with the same DMX address will respond in unison. Otherwise, each fixture will follow the control for its particular ID address.

1)Repeat steps 1, 2, and 3 from DMX Control Without ID Addressing.

2)Activate ID Addressing in each fixture:

a)Go to SET > ID.

b)Select ON.

3)Select an ID address for each fixture:

a)Go to ID.

b)Select an ID (01~66)

The Static Color mode allows for permanent RGB color mixing without a DMX controller.

1)Go to STAT.

2)Select the desired color (Red, Green, or Blue).

3)Select the desired color value (0~255).

4)Repeat for the other colors.

5)Select Strob.

6)Select the desired frequency (0~20).

Auto programs allow for dynamic RGB color mixing without a DMX controller.

1)Go to AUTO.

2)Select the desired auto program (AT. 01~10 or PR. 01~10).

You cannot edit auto programs AT. 01~10. However you can edit PR. 01~10 (see Edit Customs).

This setting allows for the programming of up to 30 scenes for each of the 10 customizable programs, including colors and effects.

1)Go to EDIT.

2)Select the desired auto program (PR. 01~10).

3)Select the desired scene (SC. 01~30).

4)Select the desired color or effect (Red, Green, Blue, Strobe, Time, or Fade).

5)Select the desired value for the color or effect (000~255 for colors and timers, or 00~20 for Strobe).

6)Repeat for the other colors or effects.

7)Repeat for the other scenes.

The Master/Slave mode allows a group of COLORado™ 1-Tri IP fixtures (the slaves) to execute simultaneously the same program, whether auto or custom, that another COLORado™ 1-Tri IP fixture (the master) is executing, without a DMX controller.

1)Set the Master Unit:

a)Set the running mode to DMX as explained in “DMX Control Without ID Addressing”.

b)Select an auto program as explained in “Auto Programs”.

2)Set the slave units:

a)Go to RUN.

b)Select SLAV.

·The fixture that runs an auto program automatically becomes the Master.

·Do not connect a DMX controller to the master or slave fixtures.

Continues on the next page

-10-

COLORado™ 1-Tri IP User Manual Rev. 01c

Image 14
Contents Page Copyright 2010 CHAUVET. All rights reserved Author Editor Manager PD ManagerTable of Contents Table of Contents Icon Meaning What is IncludedBefore You Begin Safety Notes Expected LED LifespanIntroduction FeaturesAdditional Features Options Product DescriptionGreen DMX Channel FunctionRed BlueProduct Overview AC Plug Power Linking Fuse Replacement SetupAC Power Connection Wire US Wire Europe IP66 Pin Screw ColorDMX Modes Master/Slave Connectivity DMX LinkingID Addressing Mounting Orientation RiggingDMX Personality DMX Control Without ID Addressing OperationControl Options Programming Button FunctionFrom previous When R, G, and B are 255, CAL2 will determine the output Setting DescriptionWhen R, G, and B are 255, the output will be at its maximum Upload failed due to an errorReset Whites Setting White Calibration Go to SET RestTour Notes Menu Map DMX Values AR1 + S TourARC1 + D Channel Function Value Percent/Setting Hue ~100%General Maintenance Technical InformationTroubleshooting Guide Symptom Causes ActionsExploded View Photometrics Claims Contact Us World HeadquartersTechnical Specifications Chauvet