Chauvet 1-TRI IP user manual Operation, Control Options Programming, Button Function

Page 13

Operation

4. Operation

Control Panel Description

Control Options

Programming

DMX Personality

DMX Control

Without ID

Addressing

Button

Function

<MENU>

Exits from the current menu or

function

 

 

Enables the currently displayed

<ENTER>

menu or sets the currently

selected value in to the current

 

 

function

<UP>

Navigates upwards through the

menu list and increases the

 

numeric value when in a function

<DOWN>

Navigates downwards through

the menu list and decreases the

 

numeric value when in a function

You can set the COLORado™ 1-Tri IP start address in the 001~512 DMX range. This allows for the control of up to 51 fixtures in the 10-channel TOUR personality. In addition, the ID address system allows you to assign up to 66 fixtures within the same DMX address, thus multiplying the number of fixtures you can control within a single universe. You can access the fixture’s ID address system from channel 10 when in the TOUR personality.

When programming live performances as well as cues that need to trigger on demand or on a time line, program no more than 10 fixtures on ID addressing per DMX channel. This is to remain within a one-second execution time.

Carry out all the programming procedures indicated below from the control panel. Refer to the Menu Map on page 14 to learn how the menu options relate to each other.

To go to an option, press <MENU> repeatedly until the option shows on the display.

To select an option value, press <UP> or <DOWN> until you see the desired value and press <ENTER> to accept it.

To exit to the previous menu level, press <MENU>.

This setting allows the user to choose a particular DMX personality.

1)Go to PERS.

2)Select the desired personality (TOUR, ARC1, AR1 + D, AR1 + S, or HSV).

3)Make sure that the starting addresses on the various fixtures do not overlap due to the new personality setting. See the DMX Values section.

In this mode, each unit will respond to a unique starting address from the DMX controller. All units with the same starting address will respond in unison.

1)Select the TOUR personality as shown in DMX Personality.

2)Set the running mode:

a)Go to RUN.

b)Select DMX.

3)Set the starting address:

a)Go to DMX.

b)Select the starting address (001~512).

4)Deactivate ID Addressing on each fixture:

a)Go to SET > ID.

b)Select OFF.

Make sure to deactivate ID Addressing in each fixture when using the TOUR personality. Otherwise, unintended results may occur if channel 10 is not set to “0”.

Continues on the next page

COLORado™ 1-Tri IP User Manual Rev. 01c

-9-

Image 13
Contents Page Author Editor Manager PD Manager Copyright 2010 CHAUVET. All rights reservedTable of Contents Table of Contents Before You Begin What is IncludedIcon Meaning Expected LED Lifespan Safety NotesAdditional Features Options FeaturesIntroduction Product DescriptionRed DMX Channel FunctionGreen BlueProduct Overview AC Power SetupAC Plug Power Linking Fuse Replacement Connection Wire US Wire Europe IP66 Pin Screw ColorID Addressing DMX LinkingDMX Modes Master/Slave Connectivity Orientation Rigging MountingControl Options Programming OperationDMX Personality DMX Control Without ID Addressing Button FunctionFrom previous When R, G, and B are 255, the output will be at its maximum Setting DescriptionWhen R, G, and B are 255, CAL2 will determine the output Upload failed due to an errorGo to SET Rest Reset Whites Setting White CalibrationTour Notes Menu Map DMX Values ARC1 + D TourAR1 + S ~100% Channel Function Value Percent/Setting HueTechnical Information General MaintenanceSymptom Causes Actions Troubleshooting GuideExploded View Photometrics Contact Us World Headquarters ClaimsTechnical Specifications Chauvet