General low light intensity

·

Dirty lens assembly

·

Clean the fixture regularly

 

 

·

Misaligned lens assembly

·

Install lens assembly properly

 

 

 

 

 

 

 

 

 

 

A single tri color LED

·

Faulty LED

·

Replace the LED board

 

does not illuminate

·

Faulty LED board

·

Replace the LED board

 

 

 

 

 

 

 

 

 

 

A group of tri-color LEDs

·

Faulty LED

·

Replace the LED board

 

·

Faulty LED board

·

Replace the LED board

 

does not illuminate

 

·

Faulty LED driver

· Replace the LED driver board

 

 

 

 

 

 

 

 

 

 

None of the LEDs are

·

Faulty LED PCB

·

Replace the LED board

 

·

Faulty LED Driver PCB

· Replace the LED driver board

 

illuminating

 

·

Faulty main PCB

· Replace the Display / Main board

 

 

 

 

 

 

 

 

 

 

Breaker/Fuse keeps

·

Excessive circuit load

·

Check total load placed on the electrical circuit

 

blowing

·

Short circuit along the power wires

· Check for a short in the electrical wiring

 

 

 

 

 

 

 

 

 

 

·

No power

· Check for power on power outlet

 

Fixture does not power up

·

Loose or damaged power cord

·

Check power cord

 

 

·

Blown internal fuse

·

Replace internal fuse

 

 

·

Faulty internal power supply

·

Replace internal power supply

 

 

 

 

 

 

 

 

·

Wrong DMX addressing

· Check Control Panel and unit addressing

 

 

·

Damaged DMX cables

·

Check DMX cables

 

Fixture does not respond

·

Wrong polarity on the controller

·

Check polarity switch settings on the controller

 

to DMX

·

Loose DMX cables

·

Check cable connections

 

 

 

 

·

Faulty DMX interface

·

Replace Main PCB

 

 

·

Faulty Main PCB

·

Replace Main PCB

 

 

 

 

 

 

 

 

 

·

Non DMX cables

·

Use only DMX compatible cables

 

 

·

Bouncing signals

·

Install terminator as suggested

 

 

· Long cable / low level signal

·

Install an optically coupled DMX splitter right

 

DMX signal problems

 

 

 

after fixture with strong signal

 

 

 

 

 

 

 

 

·

Too many fixtures

·

Install an optically coupled DMX splitter after

 

 

 

 

 

unit #32

 

 

·

Interference from AC wires

· Keep DMX cables separated from power cables

 

 

 

 

 

or black lights

 

 

 

 

 

 

 

If you still experience technical problems after trying the above solutions, contact CHAUVET® Technical Support.

COLORado™ 1-Tri IP User Manual Rev. 01c

-19-

Image 23
Contents Page Author Editor Manager PD Manager Copyright 2010 CHAUVET. All rights reservedTable of Contents Table of Contents Icon Meaning What is IncludedBefore You Begin Expected LED Lifespan Safety NotesProduct Description FeaturesAdditional Features Options IntroductionBlue DMX Channel FunctionRed GreenProduct Overview Connection Wire US Wire Europe IP66 Pin Screw Color SetupAC Power AC Plug Power Linking Fuse ReplacementDMX Modes Master/Slave Connectivity DMX LinkingID Addressing Orientation Rigging MountingButton Function OperationControl Options Programming DMX Personality DMX Control Without ID AddressingFrom previous Upload failed due to an error Setting DescriptionWhen R, G, and B are 255, the output will be at its maximum When R, G, and B are 255, CAL2 will determine the outputGo to SET Rest Reset Whites Setting White CalibrationTour Notes Menu Map DMX Values AR1 + S TourARC1 + D ~100% Channel Function Value Percent/Setting HueTechnical Information General MaintenanceSymptom Causes Actions Troubleshooting GuideExploded View Photometrics Contact Us World Headquarters ClaimsTechnical Specifications Chauvet