| Technical Information | |
|
|
|
|
|
| |
Troubleshooting Guide |
|
|
| |||
|
|
|
|
| ||
| Symptom | Cause(s) | Action(s) |
| ||
| General low light intensity | · | Dirty lens assembly | · | Clean the fixture regularly |
|
| · | Misaligned lens assembly | · | Install lens assembly properly | ||
|
| |||||
|
|
|
|
|
|
|
| A single tri color LED | · | Faulty LED | · | Replace the LED board | |
| does not illuminate | · | Faulty LED board | · | Replace the LED board | |
|
| |||||
|
|
|
|
|
|
|
| A group of | · | Faulty LED | · | Replace the LED board | |
| · | Faulty LED board | · | Replace the LED board | ||
| does not illuminate | |||||
| · | Faulty LED driver | · Replace the LED driver board | |||
|
| |||||
|
|
|
|
|
|
|
| None of the LEDs are | · | Faulty LED PCB | · | Replace the LED board | |
| · | Faulty LED Driver PCB | · Replace the LED driver board | |||
| illuminating | |||||
| · | Faulty main PCB | · Replace the Display / Main board | |||
|
| |||||
|
|
|
|
|
|
|
| Breaker/Fuse keeps | · | Excessive circuit load | · | Check total load placed on the electrical circuit | |
| blowing | · | Short circuit along the power wires | · Check for a short in the electrical wiring | ||
|
| |||||
|
|
|
|
|
| |
|
| · | No power | · Check for power on power outlet | ||
| Fixture does not power up | · | Loose or damaged power cord | · | Check power cord | |
|
| · | Blown internal fuse | · | Replace internal fuse | |
|
| · | Faulty internal power supply | · | Replace internal power supply | |
|
|
|
|
|
| |
|
| · | Wrong DMX addressing | · Check Control Panel and unit addressing | ||
|
| · | Damaged DMX cables | · | Check DMX cables | |
| Fixture does not respond | · | Wrong polarity on the controller | · | Check polarity switch settings on the controller | |
| to DMX | · | Loose DMX cables | · | Check cable connections | |
|
| |||||
|
| · | Faulty DMX interface | · | Replace Main PCB | |
|
| · | Faulty Main PCB | · | Replace Main PCB | |
|
|
|
|
|
|
|
|
| · | Non DMX cables | · | Use only DMX compatible cables | |
|
| · | Bouncing signals | · | Install terminator as suggested | |
|
| · Long cable / low level signal | · | Install an optically coupled DMX splitter right | ||
| DMX signal problems |
|
|
| after fixture with strong signal | |
|
|
|
|
|
| |
|
| · | Too many fixtures | · | Install an optically coupled DMX splitter after | |
|
|
|
|
| unit #32 | |
|
| · | Interference from AC wires | · Keep DMX cables separated from power cables | ||
|
|
|
|
| or black lights | |
|
|
|
|
|
|
|
If you still experience technical problems after trying the above solutions, contact CHAUVET® Technical Support.
COLORado™ |