Chauvet 1-TRI IP user manual Setup, AC Power, AC Plug Power Linking Fuse Replacement

Page 10

Setup

3. Setup

AC Power

AC Plug

Power Linking

Fuse Replacement

The COLORado™ 1-Tri IP has an auto-ranging power supply that can work with an input voltage range of 100~240 VAC, 50/60 Hz.

Make sure that you are connecting this product to the proper voltage, as per the specifications in this guide, the product’s user manual, or on the product’s sticker.

Always connect the COLORado™ 1-Tri IP to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire.

To determine the power requirements for the COLORado™ 1-Tri IP see the label affixed to the side of the fixture. Alternatively, you may refer to the corresponding specifications chart in the Technical Information chapter of this manual.

The listed current rating indicates the maximum current draw during normal operation. For more information, you may download the “Sizing the Circuit Breakers” document from the CHAUVET® Web site.

Never connect the COLORado™ 1-Tri IP to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Each COLORado™ 1-Tri IP has IP66 rated cords for Power In and Power Out with proprietary IP66 connectors. These power cords access the sealed body of the fixture through IP66 cable glands. To allow connection to power outlets, the fixture comes with a power input cord with a proprietary IP66 connector on one end and an Edison plug on the other end (US market). In case you need to replace the Edison plug on the power input cord, follow the table below.

Connection

Wire (US)

Wire (Europe)

IP66 Pin

Screw Color

AC Live

Black

Brown

1

Yellow or Brass

 

 

 

 

 

AC Neutral

White

Blue

2

Silver

 

 

 

 

 

AC Ground

Green/Yellow

Green/Yellow

3

Green

 

 

 

 

 

The COLORado™ 1-Tri IP supports power linking for up to 12 other COLORado™ 1-Tri IP fixtures at 120 VAC. The fixture also comes with an IP66 power linking cord to allow direct connection between fixtures.

The COLORado™ 1-Tri IP fixture has no external fuse that the user can change. However, it does have an internal fuse that only an authorized CHAUVET® technician should change.

-6-

COLORado™ 1-Tri IP User Manual Rev. 01c

Image 10
Contents Page Copyright 2010 CHAUVET. All rights reserved Author Editor Manager PD ManagerTable of Contents Table of Contents Before You Begin What is IncludedIcon Meaning Safety Notes Expected LED LifespanIntroduction FeaturesAdditional Features Options Product DescriptionGreen DMX Channel FunctionRed BlueProduct Overview AC Plug Power Linking Fuse Replacement SetupAC Power Connection Wire US Wire Europe IP66 Pin Screw ColorID Addressing DMX LinkingDMX Modes Master/Slave Connectivity Mounting Orientation RiggingDMX Personality DMX Control Without ID Addressing OperationControl Options Programming Button FunctionFrom previous When R, G, and B are 255, CAL2 will determine the output Setting DescriptionWhen R, G, and B are 255, the output will be at its maximum Upload failed due to an errorReset Whites Setting White Calibration Go to SET RestTour Notes Menu Map DMX Values ARC1 + D TourAR1 + S Channel Function Value Percent/Setting Hue ~100%General Maintenance Technical InformationTroubleshooting Guide Symptom Causes ActionsExploded View Photometrics Claims Contact Us World HeadquartersTechnical Specifications Chauvet