AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Reader Data Connector

6-pin terminal block supporting RS485 and Wiegand protocols for communication with the reader.

The RS485 ports support:

Two-wire RS485 half duplex

Four-wire RS485 full duplex

The Wiegand ports support:

Two-wire Wiegand

Function

 

Pin

Notes

 

 

 

 

RS485

A-

1

For full duplex RS485

 

 

 

For half duplex RS485

 

B+

2

 

 

 

 

 

 

RS485

A-

3

For full duplex RS485

 

 

 

For half duplex RS485

 

B+

4

 

 

 

 

 

 

Wiegand

D0 (Data 0)

5

For Wiegand

 

 

 

 

 

D1 (Data 1)

6

 

 

 

 

 

Important

The recommended maximum cable length is 30 m (98.4 ft).

Reader I/O Connector

6-pin terminal block for:

Auxiliary power (DC output)

Digital Input

Digital Output

0 V DC (-)

Pin 3 on the reader I/O connectors can be supervised. If the connection is interrupted, an event is activated. To use supervised inputs, install end of line resistors. Use the connection diagram for supervised inputs. See page 62.

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1

 

0 V DC

 

 

 

 

DC output

2

For powering auxiliary equipment.

12 V DC

 

 

Note: This pin can only be used as power out.

Max load = 300 mA

 

 

 

 

Configurable (Input

3–6

Digital input — Connect to pin 1 to activate, or leave

0 to max 40 V DC

or Output)

 

floating (unconnected) to deactivate.

 

 

 

Digital output — Connect to pin 1 to activate, or leave

0 to max 40 V DC, open drain,

 

 

floating (unconnected) to deactivate. If used with an

100 mA

 

 

inductive load, e.g. a relay, a diode must be connected

 

 

 

in parallel with the load, for protection against voltage

 

 

 

transients.

 

 

 

 

 