AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Function/group

Item

Specifications

 

 

 

General

Casing

Plastic

 

 

 

 

Software

Configuration and basic access control management through Internet Explorer,

 

 

Firefox, Chrome, or Safari

 

 

 

 

Memory

256 MB RAM, 4 Gbit Flash

 

 

 

 

Power

Power in: 10–30 V DC, max 26 W or Power over Ethernet

 

 

IEEE 802.3af/802.3at Type 1 Class 3

 

 

Power out & relay: 1x 12 V DC, max 500 mA 1x solid state relay 30 V DC,

 

 

max 700 mA

 

 

Power out lock: 2x 12 V DC, max 500 mA1

 

Connectors

RJ45 10BASE-T/100BASE-TX

 

 

Terminal blocks: DC power, 10 Inputs/Outputs, RS485/Wiegand, Relay

 

 

Cable size for connectors: CSA: AWG 28–16, CUL/UL: AWG 30–14

 

 

 

 

Operating conditions

0 °C to 50 °C (32 °F to 122 °F)

 

 

Humidity 20–85% RH (non-condensing)

 

 

 

 

Approvals

EN 55022 Class B, EN 50130-4, EN 61000-3-2, EN 61000-3-3, EN 55024,

 

 

EN 61000-6-1, EN 61000-6-2FCC Part 15 Subpart B Class B

 

 

ICES-003 Class B

 

 

C-tick AS/NZS CISPR22 Class B

 

 

VCCI Class B

 

 

IEC/EN/UL 60950-1, UL 294, UL 2043, EN 50581

 

 

 

 

Dimensions (HxWxD)

45.5 x 180 x 180 mm (1.8 x 7.1 x 7.1 in)

 

 

 

 

Weight

500 g (1.1 lb)

 

 

 

 

Included accessories

Connector kit, Cable ties, Installation Guide

 

 

 

 

Languages

English, German, French, Spanish, Italian

 

 

 

 

Warranty

Axis 3-year warranty with possibility to extend up to 5 years, see

 

 

www.axis.com/warranty

 

 

 

 

Optional accessories

AXIS T8120 Midspan 15 W

 

 

AXIS T8128 PoE Splitter 24 V (requires 30 W midspan)

 

 

AXIS T8129 PoE Extender Mains adaptor 24 V DC

 

 

AXIS T98A15-VE Surveillance Cabinet3

1.Power consumption dependent; max load for readers and other equipment is 7.5 W with PoE and 14 W with 10–30 V DC.

2.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/), and cryptographic software written by Eric Young (eay@cryptsoft.com)

3.In outdoor installations combining AXIS A1001 and AXIS T98A15-VE, the allowed maximum voltage is 30 V DC.

55