AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Technical Specifications

AXIS A1001 Network Door Controller

Function/group

Item

Specifications

 

 

 

 

Models

AXIS A1001 Network Door Controller

 

 

 

Door controller

Readers

Up to 2 readers per controller (Wiegand, RS485 (OSDP) with supported card formats

 

 

 

 

Doors

1–2 doors per controller1

 

Credentials

Up to 15 000 with third-party access management software depending on server

 

 

capacity

 

 

 

 

Event history

30 000 First in First out (FIFO) per controller

 

 

 

 

Access schedules

Unlimited or third-party software dependent

 

 

 

Digital I/O

I/O interface

Reader I/0: DC output: 2x 12 V DC output max 300 mA; 2x 4 configurable

 

 

inputs/outputs, (digital input: 0 to max 40 V DC, digital output: 0 to max 40 V DC,

 

 

open drain, max 100 mA)

 

 

Reader data: RS485 full duplex, RS485 half duplex, Wiegand

 

 

Auxiliary: 1x 3.3 V DC output, max 100 mA, 2x configurable inputs/output (digital

 

 

input: 0 to max 40 V DC, digital output: 0 to max 40 V DC, open drain, max 100 mA)

 

 

Door connectors: 2x 2 input for door monitors and REX (digital input: 0 to

 

 

max 40 V DC)

 

 

 

 

I/O functionality

Preconfigured for readers and door monitors, Input trigger, Output toggle/pulse

 

 

 

Network

Security

Password protection, IP address filtering, HTTPS2 encryption, IEEE 802.1X network

 

 

access control, digest authentication, user access log

 

 

 

 

Supported protocols

IPv4, HTTP, HTTPS2, TLS2, QoS layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP,

 

 

SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP,

 

 

DHCP, ARP, SOCKS

 

 

 

System

Application

Open API for software integration, including VAPIX®; specifications available at

Integration

Programming Interface

www.axis.com

 

 

ONVIF Profile C, specifications available at www.onvif.org

 

 

Support for access control as a service with One-Click Connection

 

 

 

Events & Alarms

Tamper detection

Removal of unit cover/tamper front

 

 

Removal of unit from wall/tamper back

 

 

Reader tamper

 

 

 

 

Event log

Configurable by time and topic, Alarm acknowledgement

 

 

 

 

Event actions

Notification via email, HTTP and TCP, External output port, Status LED

 

 

 

 

Event triggers

Access Point: Access point enabled

 

 

Configuration: Access point changed, Access point removed, Area changed, Area

 

 

removed, Door changed, Door removed

 

 

Door: Door alarm, Door double-lock monitor, Door lock monitor, Door mode, Door

 

 

monitor, Door warning

 

 

Event Logger: Alarm

 

 

Hardware: Casing open, Network, peer connection

 

 

Input Signal Digital input port, Manual trigger, Virtual inputs

 

 

Schedule: Interval, Pulse

 

 

System: System ready

 

 

Time: Recurrence, Use schedule

 

 

 