AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Network Connector

RJ45 Ethernet connector. Supports Power over Ethernet (PoE). Use Category 5e cables or higher.

Function

Specifications

 

 

Power and Ethernet

Power over Ethernet IEEE 802.3af/802.3at Type 1 Class 3, 44–57 V DC

 

Max load on outputs = 7.5 W

 

 

Power Lock Connector

4-pin terminal block for powering one or two locks (DC output). The lock connector can also be used to power external devices.

Connect locks and loads to the pins according to the hardware pin chart generated through the hardware configuration.

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1, 3

 

0 V DC

 

 

 

 

0 V DC, floating, or

2, 4

For controlling up to two 12 V locks. Use the hardware

12 V DC

12 V DC

 

pin chart. See Configure the Hardware on page 13.

Max total load = 500 mA

 

 

 

 

Power & Relay Connector

6-pin terminal block with built-in relay for:

External devices

Auxiliary power (DC output)

0 V DC (-)

Connect locks and loads to the pins according to the hardware pin chart generated through the hardware configuration.

Function

Pin

Notes

Specifications

 

 

 

 

0 V DC (-)

1, 4

 

0 V DC

 

 

 

 

Relay

2–3

For connecting relay devices. Use the hardware pin

Max current = 700 mA

 

 

chart. See Configure the Hardware on page 13.

Max voltage = +30 V DC

 

 

The two relay pins are galvanically separated from the

 

 

 

rest of the circuitry.

 

 

 

 

 

12 V DC

5

For powering auxiliary equipment.

Max voltage = +12 V DC

 

 

Note: This pin can only be used as power out.

Max load = 500 mA

 

 

 

 

24 V DC

6

Not used

 

 

 

 

 

Tampering Alarm Pin Header

Two 2-pin headers for bypassing:

Back tampering alarm (TB)

Front tampering alarm (TF)

60

Page 60
Image 60
Axis Communications A1001 Network Connector, Power Lock Connector, Power & Relay Connector, Tampering Alarm Pin Header