AXIS A1001 Network Door Controller & AXIS Entry Manager

Technical Specifications

Function/group

Item

Specifications

 

 

 

General

Casing

Plastic

 

 

 

 

Software

Configuration and basic access control management through Internet Explorer,

 

 

Firefox, Chrome, or Safari

 

 

 

 

Memory

256 MB RAM, 4 Gbit Flash

 

 

 

 

Power

Power in: 10–30 V DC, max 26 W or Power over Ethernet

 

 

IEEE 802.3af/802.3at Type 1 Class 3

 

 

Power out & relay: 1x 12 V DC, max 500 mA 1x solid state relay 30 V DC,

 

 

max 700 mA

 

 

Power out lock: 2x 12 V DC, max 500 mA1

 

Connectors

RJ45 10BASE-T/100BASE-TX

 

 

Terminal blocks: DC power, 10 Inputs/Outputs, RS485/Wiegand, Relay

 

 

Cable size for connectors: CSA: AWG 28–16, CUL/UL: AWG 30–14

 

 

 

 

Operating conditions

0 °C to 50 °C (32 °F to 122 °F)

 

 

Humidity 20–85% RH (non-condensing)

 

 

 

 

Approvals

EN 55022 Class B, EN 50130-4, EN 61000-3-2, EN 61000-3-3, EN 55024,

 

 

EN 61000-6-1, EN 61000-6-2FCC Part 15 Subpart B Class B

 

 

ICES-003 Class B

 

 

C-tick AS/NZS CISPR22 Class B

 

 

VCCI Class B

 

 

IEC/EN/UL 60950-1, UL 294, UL 2043, EN 50581

 

 

 

 

Dimensions (HxWxD)

45.5 x 180 x 180 mm (1.8 x 7.1 x 7.1 in)

 

 

 

 

Weight

500 g (1.1 lb)

 

 

 

 

Included accessories

Connector kit, Cable ties, Installation Guide

 

 

 

 

Warranty

Axis 3-year warranty with possibility to extend up to 5 years, see

 

 

www.axis.com/warranty

 

 

 

 

Optional accessories

AXIS T8120 Midspan 15 W

 

 

AXIS T8128 PoE Splitter 24 V (requires 30 W midspan)

 

 

AXIS T8129 PoE Extender Mains adaptor 24 V DC

 

 

AXIS T98A15-VE Surveillance Cabinet3

1.Power consumption dependent; max load for readers and other equipment is 7.5 W with PoE and 14 W with 10–30 V DC.

2.This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/), and cryptographic software written by Eric Young (eay@cryptsoft.com)

3.In outdoor installations combining AXIS A1001 and AXIS T98A15-VE, the allowed maximum voltage is 30 V DC.

Connectors

For information about the connectors’ positions, see Hardware Overview on page 5 .

For connection diagrams and information about the hardware pin chart generated through the hardware configuration, see Connection Diagrams on page 61 and Configure the Hardware on page 13.

The following section describes the connectors’ technical specifications.

57

Page 57
Image 57
Axis Communications A1001 user manual Connectors