Crestron Residential Lighting Design Guide | GreenLight |
Terminal Blocks and Modules
The Crestron CLT terminal blocks and modules are considered a single entity and must be used together. In
The module connects to the terminal block and performs dimming or switching control of the loads, limited to 16A total per module. The unit requires 120VAC 60 Hz, single phase input voltage.
An oversize heat sink dissipates heat efficiently. The LEDs on the module indicate communication to a Cresnet® network, input power to the module, and output power to the load.
Terminal Blocks, Rails, and Labels (Inverted, right side units shown)
NOTES: When connecting dimming loads to an arc fault breaker, the load should not exceed 1000 watts per breaker.
Each terminal block includes a terminal rail for mounting the terminal block in the enclosure. Terminal rails and blocks do not occupy a module space within an enclosure.
Terminal blocks are installed along the left side of
Doc. 5999F | 19 |