Crestron electronic Residential Lighting manual Cresnet Wall Box Switches, Clw-Slvs

Page 54

Wall Box Dimmers and Switches

Residential Lighting Design Guide

Cresnet Wall Box Switches

Model

Load

Features

CLW-SW

Wall Box

Switch

(Stand-alone)

CLW-SW1

Wall Box

Switch, Single

Button

(Stand-alone)

CLW-SWS1

Wall Box

Master Switch,

Single Button

(Master)

CLW-SLVS1

Wall Box Slave

Switch, Single

Button

(Slave)

CLW-SWS

Wall Box Master Switch

(Master)

CLW-SLVS

Wall Box Slave Switch

(Multipoint

Slave)

Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low-voltage and neon/cold cathode loads up to 1000VA/750 watts. Fluorescent ballasts, high- intensity discharge lighting, and ceiling fans can also be switched.

Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low voltage and neon/cold cathode loads up to 1000VA/750 watts.

Fluorescent ballasts, high- intensity discharge lighting, and ceiling fans can also be switched.

Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low voltage and neon/cold cathode loads up to 1000VA/750 watts.

Fluorescent ballasts, high- intensity discharge lighting, and ceiling fans can also be switched

Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low-voltage and neon/cold cathode loads up to 1000VA/750 watts.

1000 watt electronic light switch designed to mount in a standard electrical gang box

1000-Watt electronic light switch designed to mount in a standard electrical gang box

Large button provides instant on/off control of the load, while the small button turns the load off following a preset time delay. The slide switch selects between ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.

NOTE: The wall box switches do not support fan speed control. Use the CLX-1FAN4 for fan speed control.

Provides instant turn-on control of the load. Pressing the button again turns the load off following a preset time delay. The time delay can be overridden by tapping the button a second time, turning the load off instantly. The slide switch on the CLW-SW1 selects ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.

Multiple units may be ganged side-by-side along with other CLW-Series switches and dimmers or non-Crestron devices. The single large button on the CLW-SWS1 provides instant turn-on control of the load. Pressing the button again turns the load off following a preset time delay. The time delay can be overridden by tapping the button a second time, turning the load off instantly. The slide switch on the CLW-SWS1 selects ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.

One-gang wall mount slave switch designed for use with the CLW-SWS1 Wall Box Master Switch to provide multipoint switching control of a single load. The single pushbutton on the CLW-SLVS1 provides parallel functionality to that on the CLW-SWS1.

Serves as the master for multipoint switching control of a single load. Multi-point switching functionality (similar to

3-way or 4-way switching) is enabled by using the CLW- SWS with one or more CLW-SLVS Slave Switches. The large button on the CLW-SWS allows for instant on/off control of the load, the small button turns the load off following a preset time delay. The slide switch selects between ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.

NOTE: The wall box switches do not support fan speed control. Use the CLX-1FAN4 for fan speed control.

One-gang wall mount slave switch designed for use with the CLW-SWS Wall Box Master Switch to provide multipoint switching control of a single load. The pushbuttons on the CLW-SLVS provide parallel functionality to those on the CLW-SWS.

NOTE: In systems, only the master unit is connected to Cresnet®. Slave units are connected by the120V (Traveler) wire.

Doc. 5999F

49

Image 54
Contents Crestron Green Light Residential Lighting Design Guide Page Page Contents Page Single Solution Control System Crestron Exclusive IntroductionCrestron Control Technology Crestron Green LightTMSystem Design Wireless Systems Lighting System Design TypesCentralized Wired Systems Decentralized Wired Systems System Design Crestron Residential Lighting Design GuideHybrid Systems Specifying a Lighting System Required Load Schedule ItemsLoad Schedule Example Load Schedule with Panel Terminations TotalOrdering a Crestron Residential Lighting System Residential Lighting Wiring PlanEquipment List Specification Steps to order a lighting systemGreen Light Options CAEN- Series EnclosuresSpecifications Caen Enclosures Crestron Residential Lighting Design GuideCaen 2X1, 4X1, and 7X1 Framing Caen InstallationCaen Enclosure Framing Caen 4X2 FramingCaen Wiring Universal Mounting Plates Cover Extension Kits CLX Lighting Control Modules CLX-Series Lighting Control Modules Model Load RatingTerminal Blocks and Modules Module Installation Single Width Enclosure MountingCresnet Terminal Block for Caen Automation Enclosures Doc F Features DIN Rail InstallationCrestron DIN Rail Products Example DIN Rail System DIN-AP2 Auto Load Detection Phase-Synchronous Detection CircuitryDIN-1DIMU4 Short Circuit ProtectionDIN-8SW8 DIN-4DIMFLV4DIN-2MC2 Analog Outputs DIN-AO8DIN-IO8 VersiportsDIN-PWS50 Cresnet Power DistributionDIN-BLOCK Cresnet DistributionDIN-HUB Segment Cresnet HubInterface Equipment TPS Isys G-Series with Crestron Home or QuickMedia Wall Mount TouchpanelsTPS Series Isys Tpmc Isys I/O with Crestron Home or QuickMediaTPS-4000L TPMC-8LTPS-4L Tilt Touchpanels TPS-4000TPMC-8X Tpmc Series Isys i/O WiFi TouchpanelsTPMC-8T TPMC-4XGMT-1000C Wireless Touchpanels and HandheldsTPS-6X ML-600Keypads C2N-DB Series Decorator KeypadsC2N-DB Mounting CNX Designer Series Keypads Mounting in Single-Gang BoxCameo Cameo Mounting Options Cameo Flush Mount Mud Ring Mount KitILux Integrated Lighting Control System ILux Features Wireless iLux Remote Multi-Unit Expansion Control System Integration ILux Expansion Modules Model Load FunctionUL2043 rated for use in air handling spaces Expansion Modules Wiring Diagrams Wall Box Dimmers and Switches Model Load Features Cresnet Wall Box DimmersCresnet Wall Box Switches CLW-SLVSInfiNET Wireless Technology InfiNET Dimmers, Switches, and Thermostat Example infiNET system Control Processors PAC2 Lighting Control ProcessorPAC2 Power Management & Requirements PAC2M Professional Automation Mini Control System Series Control SystemOverride Basic Lighting System Interconnections Occupancy and Photocell Sensors C2N-SDC-DC Integrated Shade and Drape ControllersC2N-SDC C2N-SSC-2Integrated Partner Modules Integrated SystemsAppendix a Example Residential Lighting System Residential Lighting Design Guide Load Schedule Report ExampleLoad Schedule with Panel Terminations DescriptionCircuits and Interfaces Module Wiring PAC2 Lighting Control Processor Connections Appendix B Touchpanel Comparison Charts Appendix B Wireless Touchpanels & Handheld Remotes Isys I/O WiFi MiniTouch Handheld RemotesSimple Lighting Coverage Areas Appendix C General Lighting Design ConsiderationsStatic and Dynamic Elements Task Lighting for Specific Work AreasFocal Lighting Ambient Lighting for Mood and HighlightsDecorative Lighting Key LightGrazing and Washing Surfaces Switch and Dimmer LocationsColor Temperature Color RenditionAppendix D Glossary of Lighting Terminology Crestron Lighting Software Appendix D Crestron Residential Lighting Design Guide Crestron Lighting Software Appendix D TWIN-TUBE see Compact Fluorescent Lamp