Control Processors

Control Processors

PAC2 Lighting Control Processor

The PAC2 enables efficient control of lighting and other systems such as HVAC and security, and has been specifically designed for the Crestron automation enclosure and the Crestron lighting system (although other Crestron processors can also be used).

The PAC2 occupies one module space in single-width enclosures and two module spaces in double-width enclosures.

NOTE: Crestron recommends that the control processor be mounted within a separate CAEN enclosure to create a simplified low voltage wiring center.

Cresnet® Distribution

The built-in Cresnet Hub/Repeater serves as a repeater, splitter, and wiring block. The hub allows for 252 or more devices (touchpanels, keypads, etc.); 32 per segment (A-

H)and distribution up to 3000 feet of Cresnet cable run per segment. There are eight independent segments, each with four Cresnet connectors wired in parallel.

In addition, there is a master NET port on the bottom panel. The eight NET (A-H) activity LEDs illuminate when a device on the respective segment transmits data. When powered by the internal power supply, a maximum of 50 watts (DC) is available for all connected network devices. The LEDs indicate communication on the Cresnet link.

Memory Expansion

The on-board 36MB memory is enhanced with a 4GB expansion slot that supports off-the-shelf Type II compact flash memory and the IBM Microdrive® hard disk drive, for

on-board storage of program and touchpanel files, room and equipment profiles, upgrades, databases, and schedules. Memory is non-volatile to protect against power loss.

Ethernet and e-Control®2

The unique Crestron dual bus system, with its high speed I/O bus architecture, provides blazing fast throughput, system wide. The two 40Mb/s Y-BUS expansion slots offer the option of installing any of the CNX-series cards and all C2-series control cards listed in the Crestron Product Catalog. The 300Mb/s Z-BUS expansion slot is designed for super high speed control card applications such as 10/100 Ethernet, available via the Crestron single-port C2ENET-1 or dual-port C2ENET-2 cards.

The PAC2 also provides true secure network communications, which is required for today's corporate networks, automated residence systems, and the Internet. The Dual Port 10/100BaseT Ethernet card (C2ENET-2) supports dynamic and static IP addressing and full duplex TCP/IP and UDP/IP. It offers a WAN port for Internet and remote-location communications and a LAN port for local in-home or in-office use. A built-in firewall delivers network security with the Network Address Translator (NAT) and router functions. The built-in Web server uses memory storage on a compact flash card for remote access and control.

Backup and Override

The PAC2 provides external connections for both a back- up processor and emergency override closure signals. In the absence of Cresnet, a signal is generated to switch power and communication of the Cresnet system to the back-up processor. When the override connection receives a contact closure, a signal is passed to the lighting modules via the fifth wire of the module interconnect cable, and the lights are turned on to a programmed preset emergency level. They remain at this level until that contact closure is removed.

The Backup Net Input connector allows a backup control system to automatically take control of the Cresnet network in the unlikely event of an internal processor failure. The exclusive, built-in Cresnet watchdog switches over when the CPU fails.

Doc. 5999F

53

Image 58
Contents Crestron Green Light Residential Lighting Design Guide Page Page Contents Page Single Solution Control System Crestron Exclusive IntroductionCrestron Control Technology Crestron Green LightTMSystem Design Wireless Systems Lighting System Design TypesCentralized Wired Systems Decentralized Wired Systems System Design Crestron Residential Lighting Design GuideHybrid Systems Required Load Schedule Items Specifying a Lighting SystemLoad Schedule Example Load Schedule with Panel Terminations TotalOrdering a Crestron Residential Lighting System Residential Lighting Wiring PlanEquipment List Specification Steps to order a lighting systemGreen Light Options CAEN- Series EnclosuresSpecifications Caen Enclosures Crestron Residential Lighting Design GuideCaen 2X1, 4X1, and 7X1 Framing Caen InstallationCaen Enclosure Framing Caen 4X2 FramingCaen Wiring Universal Mounting Plates Cover Extension Kits CLX Lighting Control Modules CLX-Series Lighting Control Modules Model Load RatingTerminal Blocks and Modules Module Installation Single Width Enclosure MountingCresnet Terminal Block for Caen Automation Enclosures Doc F DIN Rail Installation FeaturesCrestron DIN Rail Products Example DIN Rail System DIN-AP2 Auto Load Detection Phase-Synchronous Detection CircuitryDIN-1DIMU4 Short Circuit ProtectionDIN-4DIMFLV4 DIN-8SW8DIN-2MC2 Analog Outputs DIN-AO8DIN-IO8 VersiportsDIN-PWS50 Cresnet Power DistributionDIN-BLOCK Cresnet DistributionDIN-HUB Segment Cresnet HubInterface Equipment TPS Isys G-Series with Crestron Home or QuickMedia Wall Mount TouchpanelsTPS Series Isys Tpmc Isys I/O with Crestron Home or QuickMediaTPMC-8L TPS-4000LTPS-4L Tilt Touchpanels TPS-4000TPMC-8X Tpmc Series Isys i/O WiFi TouchpanelsTPMC-8T TPMC-4XGMT-1000C Wireless Touchpanels and HandheldsTPS-6X ML-600C2N-DB Series Decorator Keypads KeypadsC2N-DB Mounting CNX Designer Series Keypads Mounting in Single-Gang BoxCameo Cameo Mounting Options Cameo Flush Mount Mud Ring Mount KitILux Integrated Lighting Control System ILux Features Wireless iLux Remote Multi-Unit Expansion Control System Integration Model Load Function ILux Expansion ModulesUL2043 rated for use in air handling spaces Expansion Modules Wiring Diagrams Wall Box Dimmers and Switches Model Load Features Cresnet Wall Box DimmersCresnet Wall Box Switches CLW-SLVSInfiNET Wireless Technology InfiNET Dimmers, Switches, and Thermostat Example infiNET system Control Processors PAC2 Lighting Control ProcessorPAC2 Power Management & Requirements PAC2M Professional Automation Mini Control System Series Control SystemOverride Basic Lighting System Interconnections Occupancy and Photocell Sensors C2N-SDC-DC Integrated Shade and Drape ControllersC2N-SDC C2N-SSC-2Integrated Partner Modules Integrated SystemsAppendix a Example Residential Lighting System Residential Lighting Design Guide Load Schedule Report ExampleLoad Schedule with Panel Terminations DescriptionCircuits and Interfaces Module Wiring PAC2 Lighting Control Processor Connections Appendix B Touchpanel Comparison Charts Appendix B Wireless Touchpanels & Handheld Remotes Isys I/O WiFi MiniTouch Handheld RemotesSimple Lighting Coverage Areas Appendix C General Lighting Design ConsiderationsStatic and Dynamic Elements Task Lighting for Specific Work AreasFocal Lighting Ambient Lighting for Mood and HighlightsDecorative Lighting Key LightGrazing and Washing Surfaces Switch and Dimmer LocationsColor Temperature Color RenditionAppendix D Glossary of Lighting Terminology Crestron Lighting Software Appendix D Crestron Residential Lighting Design Guide Crestron Lighting Software Appendix D TWIN-TUBE see Compact Fluorescent Lamp