Crestron electronic Residential Lighting manual Load Schedule with Panel Terminations, Description

Page 68

Residential Lighting Design Guide

Appendix A

 

 

 

 

Load Schedule with Panel Terminations

 

 

 

 

Project: Example Residence

 

 

 

 

Dealer: Crestron

 

 

 

 

 

 

Creator: Crestron D3 Pro v2.3.7

 

 

 

Description:

 

 

 

 

 

 

Date: 11/4/2003 System Number: 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Controlled Ckt

Controlled

 

 

 

 

Fixture

Fixture

Total

 

 

 

 

Area

Room

Name

Ckt No.

Fixture

Load Type

Dim

Emergency

Watts

Qty

Watts

Enclosure

Slot

Module

Output

Main

Bathroom

Downlights

009

Downlights

Incandescent

yes

no

100

1

100

Enclosure 1

2

CLX-

1

Floor

1

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Bathroom

Downlights 2

008

Downlights

Incandescent

yes

no

100

2

200

Enclosure 1

2

CLX-

2

Floor

1

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Bathroom

Downlights 3

006

Downlights

Incandescent

yes

no

100

2

200

Enclosure 1

2

CLX-

3

Floor

1

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Bathroom

Drapes

019

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

1

Floor

1

 

 

 

 

 

 

 

 

 

 

 

1MC4

 

Main

Bathroom

Exhaust Fan

007

Exhaust Fan

Switched

no

no

200

1

200

N / A

N / A

Interface

1

Floor

1

 

 

 

 

 

 

 

 

 

 

 

2

 

Main

Bathroom

Downlights

011

Downlights

Incandescent

yes

no

100

1

100

Enclosure 1

2

CLX-

4

Floor

2

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Bathroom

Downlights 2

010

Downlights

Incandescent

yes

no

100

3

300

Enclosure 1

2

CLX-

5

Floor

2

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Bathroom

Drapes

021

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

2

Floor

2

 

 

 

 

 

 

 

 

 

 

 

1MC4

 

Main

Bathroom

Exhaust Fan

012

Exhaust Fan

Switched

no

no

200

1

200

N / A

N / A

Interface

1

Floor

2

 

 

 

 

 

 

 

 

 

 

 

4

 

Main

Bedroom

Ceiling Fan

022

Ceiling Fan

Ceiling Fan

no

no

100

1

100

Enclosure 1

6

CLX-

1

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1FAN4

 

Main

Bedroom

Downlights

005

Downlights

Incandescent

yes

no

250

2

500

Enclosure 1

2

CLX-

7

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Bedroom

Downlights 2

004

Downlights

Incandescent

yes

no

100

4

400

Enclosure 1

3

CLX-

1

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1DIM4

 

Main

Bedroom

Downlights 3

003

Downlights

Incandescent

yes

no

100

1

100

N / A

N / A

Interface

1

Floor

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Main

Bedroom

Downlights 4

002

Downlights

Incandescent

yes

no

100

1

100

N / A

N / A

Interface

1

Floor

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Main

Bedroom

Downlights 5

001

Downlights

Incandescent

yes

no

100

2

200

Enclosure 1

3

CLX-

2

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1DIM4

 

Main

Bedroom

Drapes

018

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

3

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1MC4

 

Main

Bedroom

Drapes 2

017

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

4

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1MC4

 

Main

Bedroom

Drapes 3

016

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

5

CLX-

1

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1MC4

 

Main

Foyer

Downlights

013

Downlights

Incandescent

yes

no

100

4

400

Enclosure 1

2

CLX-

6

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1DIM8

 

Main

Sauna

Drapes

020

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

5

CLX-

2

Floor

 

 

 

 

 

 

 

 

 

 

 

 

1MC4

 

 

 

 

 

 

 

 

 

 

 

*Calculation of load wattage includes transformer loss.

The following three pages contain the complete application diagrams of this example system, Circuits and Interfaces, Module Wiring, and PAC2 Connections, divided up to fit the space available. The complete diagram is available on line at: http://www.crestron.com/dealer-tech_resources/application_diagrams.asp.

Doc. 5999F

63

Image 68
Contents Crestron Green Light Residential Lighting Design Guide Page Page Contents Page Single Solution Control System Crestron Exclusive IntroductionCrestron Control Technology Crestron Green LightTMSystem Design Wireless Systems Lighting System Design TypesCentralized Wired Systems Decentralized Wired Systems System Design Crestron Residential Lighting Design GuideHybrid Systems Load Schedule Specifying a Lighting SystemRequired Load Schedule Items Example Load Schedule with Panel Terminations TotalResidential Lighting Wiring Plan Equipment List SpecificationOrdering a Crestron Residential Lighting System Steps to order a lighting systemGreen Light Options CAEN- Series EnclosuresSpecifications Caen Enclosures Crestron Residential Lighting Design GuideCaen Installation Caen Enclosure FramingCaen 2X1, 4X1, and 7X1 Framing Caen 4X2 FramingCaen Wiring Universal Mounting Plates Cover Extension Kits CLX Lighting Control Modules CLX-Series Lighting Control Modules Model Load RatingTerminal Blocks and Modules Module Installation Single Width Enclosure MountingCresnet Terminal Block for Caen Automation Enclosures Doc F Crestron DIN Rail Products FeaturesDIN Rail Installation Example DIN Rail System DIN-AP2 Phase-Synchronous Detection Circuitry DIN-1DIMU4Auto Load Detection Short Circuit ProtectionDIN-2MC2 DIN-8SW8DIN-4DIMFLV4 DIN-AO8 DIN-IO8Analog Outputs VersiportsCresnet Power Distribution DIN-BLOCKDIN-PWS50 Cresnet DistributionDIN-HUB Segment Cresnet HubInterface Equipment Wall Mount Touchpanels TPS Series IsysTPS Isys G-Series with Crestron Home or QuickMedia Tpmc Isys I/O with Crestron Home or QuickMediaTPS-4L TPS-4000LTPMC-8L Tilt Touchpanels TPS-4000Tpmc Series Isys i/O WiFi Touchpanels TPMC-8TTPMC-8X TPMC-4XGWireless Touchpanels and Handhelds TPS-6XMT-1000C ML-600C2N-DB Mounting KeypadsC2N-DB Series Decorator Keypads CNX Designer Series Keypads Mounting in Single-Gang BoxCameo Cameo Mounting Options Cameo Flush Mount Mud Ring Mount KitILux Integrated Lighting Control System ILux Features Wireless iLux Remote Multi-Unit Expansion Control System Integration UL2043 rated for use in air handling spaces ILux Expansion ModulesModel Load Function Expansion Modules Wiring Diagrams Wall Box Dimmers and Switches Model Load Features Cresnet Wall Box DimmersCresnet Wall Box Switches CLW-SLVSInfiNET Wireless Technology InfiNET Dimmers, Switches, and Thermostat Example infiNET system Control Processors PAC2 Lighting Control ProcessorPAC2 Power Management & Requirements PAC2M Professional Automation Mini Control System Series Control SystemOverride Basic Lighting System Interconnections Occupancy and Photocell Sensors Integrated Shade and Drape Controllers C2N-SDCC2N-SDC-DC C2N-SSC-2Integrated Partner Modules Integrated SystemsAppendix a Example Residential Lighting System Residential Lighting Design Guide Load Schedule Report ExampleLoad Schedule with Panel Terminations DescriptionCircuits and Interfaces Module Wiring PAC2 Lighting Control Processor Connections Appendix B Touchpanel Comparison Charts Appendix B Wireless Touchpanels & Handheld Remotes Isys I/O WiFi MiniTouch Handheld RemotesAppendix C General Lighting Design Considerations Static and Dynamic ElementsSimple Lighting Coverage Areas Task Lighting for Specific Work AreasAmbient Lighting for Mood and Highlights Decorative LightingFocal Lighting Key LightSwitch and Dimmer Locations Color TemperatureGrazing and Washing Surfaces Color RenditionAppendix D Glossary of Lighting Terminology Crestron Lighting Software Appendix D Crestron Residential Lighting Design Guide Crestron Lighting Software Appendix D TWIN-TUBE see Compact Fluorescent Lamp