Crestron electronic Residential Lighting Cresnet Terminal Block for Caen Automation Enclosures

Page 26

Crestron Residential Lighting Design Guide

DIN Rail Products

Cresnet® Terminal Block for CAEN Automation Enclosures

The CAEN-BLOCK is a Cresnet terminal block designed specifically for Crestron lighting and automation systems to link remote enclosures to the central PAC2 or PAC2M control system. The CAEN-BLOCK mounts at the bottom of each CAEN enclosure that does not contain a control system to provide Cresnet and override signal connectivity for CLX-series lighting control modules. The CAEN-BLOCK serves as a parallel distribution block for multiple Cresnet cables, and especially provides for connection of the Cresnet and override signal cables from the central control system.

Crestron Network Block (CAEN-BLOCK) provides four termination ports for Cresnet wiring. The unit has two 5-pin connections that provide communication to the modules. Contact closure signals that produce an emergency override of the modules are also sent through these connections.

When a switch contact closure is received between the “G” connections and the “L” or “R” connection (R is used in a double-wide enclosure only) on the CAEN BLOCK, the respective left or right column of modules will set the lights to the programmed emergency override state.

The CAEN-BLOCK unit is a pass-through device with a Cresnet power factor of zero.

Network Block Dimensions and Weight

Height

Width

Depth

Weight

2 in

6 in

1 ¾ in

3.4 oz

NOTES: A module terminal block (CLT-series device) must be ordered for each module. The corresponding CLT terminal block is installed in the enclosure for high voltage wire termination. Each terminal block includes a terminal rail for mounting the block in the enclosure. Terminal rails and blocks do not occupy a module space within an enclosure.

CAEN-series enclosures are required to install CLX-series lighting modules.

Doc. 5999F

21

Image 26
Contents Crestron Green Light Residential Lighting Design Guide Page Page Contents Page Single Solution Control System Crestron Exclusive IntroductionCrestron Control Technology Crestron Green LightTMSystem Design Wireless Systems Lighting System Design TypesCentralized Wired Systems Decentralized Wired Systems System Design Crestron Residential Lighting Design GuideHybrid Systems Load Schedule Specifying a Lighting SystemRequired Load Schedule Items Example Load Schedule with Panel Terminations TotalOrdering a Crestron Residential Lighting System Residential Lighting Wiring PlanEquipment List Specification Steps to order a lighting systemGreen Light Options CAEN- Series EnclosuresSpecifications Caen Enclosures Crestron Residential Lighting Design GuideCaen 2X1, 4X1, and 7X1 Framing Caen InstallationCaen Enclosure Framing Caen 4X2 FramingCaen Wiring Universal Mounting Plates Cover Extension Kits CLX Lighting Control Modules CLX-Series Lighting Control Modules Model Load RatingTerminal Blocks and Modules Module Installation Single Width Enclosure MountingCresnet Terminal Block for Caen Automation Enclosures Doc F Crestron DIN Rail Products FeaturesDIN Rail Installation Example DIN Rail System DIN-AP2 Auto Load Detection Phase-Synchronous Detection CircuitryDIN-1DIMU4 Short Circuit ProtectionDIN-2MC2 DIN-8SW8DIN-4DIMFLV4 Analog Outputs DIN-AO8DIN-IO8 VersiportsDIN-PWS50 Cresnet Power DistributionDIN-BLOCK Cresnet DistributionDIN-HUB Segment Cresnet HubInterface Equipment TPS Isys G-Series with Crestron Home or QuickMedia Wall Mount TouchpanelsTPS Series Isys Tpmc Isys I/O with Crestron Home or QuickMediaTPS-4L TPS-4000LTPMC-8L Tilt Touchpanels TPS-4000TPMC-8X Tpmc Series Isys i/O WiFi TouchpanelsTPMC-8T TPMC-4XGMT-1000C Wireless Touchpanels and HandheldsTPS-6X ML-600C2N-DB Mounting KeypadsC2N-DB Series Decorator Keypads CNX Designer Series Keypads Mounting in Single-Gang BoxCameo Cameo Mounting Options Cameo Flush Mount Mud Ring Mount KitILux Integrated Lighting Control System ILux Features Wireless iLux Remote Multi-Unit Expansion Control System Integration UL2043 rated for use in air handling spaces ILux Expansion ModulesModel Load Function Expansion Modules Wiring Diagrams Wall Box Dimmers and Switches Model Load Features Cresnet Wall Box DimmersCresnet Wall Box Switches CLW-SLVSInfiNET Wireless Technology InfiNET Dimmers, Switches, and Thermostat Example infiNET system Control Processors PAC2 Lighting Control ProcessorPAC2 Power Management & Requirements PAC2M Professional Automation Mini Control System Series Control SystemOverride Basic Lighting System Interconnections Occupancy and Photocell Sensors C2N-SDC-DC Integrated Shade and Drape ControllersC2N-SDC C2N-SSC-2Integrated Partner Modules Integrated SystemsAppendix a Example Residential Lighting System Residential Lighting Design Guide Load Schedule Report ExampleLoad Schedule with Panel Terminations DescriptionCircuits and Interfaces Module Wiring PAC2 Lighting Control Processor Connections Appendix B Touchpanel Comparison Charts Appendix B Wireless Touchpanels & Handheld Remotes Isys I/O WiFi MiniTouch Handheld RemotesSimple Lighting Coverage Areas Appendix C General Lighting Design ConsiderationsStatic and Dynamic Elements Task Lighting for Specific Work AreasFocal Lighting Ambient Lighting for Mood and HighlightsDecorative Lighting Key LightGrazing and Washing Surfaces Switch and Dimmer LocationsColor Temperature Color RenditionAppendix D Glossary of Lighting Terminology Crestron Lighting Software Appendix D Crestron Residential Lighting Design Guide Crestron Lighting Software Appendix D TWIN-TUBE see Compact Fluorescent Lamp