CAMERA ID SETTING

4Use the cursor button (j or l) to move the cursor to

POSITION, and then press the SET button. The camera ID will be displayed on one line.

SYNC SETTING (SYNC)

Initial setting is internal synchronization (INT), so it does not need to be set again. Follow the steps below to change the setting to power source synchronization (L-L).

CAMERA ID SETTING

CAM1

Power source synchronization (L-L) setting

ABCDEFGHIJKLM NOPQRSTUVWXYZ 0123456789 :-‚

ID CAM1????????????

POSITION

SET

PRESET

OFF

 

MENU

BACK

Camera ID

1MAIN MENU

LANGUAGE

SET

CAMERA ID

OFF

 

SYNC

INT

 

PRIVACY MASK

SET

LENS

SET

MIRROR

OFF

 

2L-L SETTING (V SYNC PHASE)

ú------

+------

ü 0

English

(Displaying the ID on 2 lines.)

1Use the cursor button (d or c) to move the cursor to the location in the ID field where the carriage return is wanted.

VIEW SETTING

1

OPTION

SET

PRESET

OFF

 

MENU

END

 

PRESET

OFF

MENU

BACK

2Use the cursor button (j l d c) to move the cursor to the carriage return mark (y) at the lower right corner of the character selection palette, and then press the SET button.

5Moving the on-screen title display position

Use the cursor button (j l d c) to move the title display to the preferred position on the screen, then press the SET button.

The CAMERA ID SETTING screen will reappear.

1Use the cursor button (j l d c) to select L-L for

SYNC, then press the SET button. The L-L SETTING screen will appear.

2Use the cursor button (d or c) to adjust the position of the vertical synchronization indicator shown on the screen.

The numerical value will change, allowing adjustment of vertical synchronization.

To close the menu screen or return to the previous screen, select BACK or END for MENU and press the SET button.

12

Image 13
Contents Propos de ce manuel VCC-ZM300PContents Accessories Main FeaturesPrecautions Parts Names and Functions Parts Names and Functions Connections Power supply choicesAC 24 V connection DC 12 V connectionCoaxial cable type and maximum length ConnectionsDISPLAYING/CLOSING the Menu Screen Setting to ON, then press the SET buttonSub-menu screen Cursor button SET buttonMenu Item Flow and Menu Operation Language screen will appear Language SettingInterface language becomes French Camera ID setting Example Setting the Camera ID to CAM Camera ID SettingID CAM 1 ???????????? Camera ID screenCamera ID Setting Sync Setting SyncPower source synchronization L-L setting Mask setting Privacy Mask Setting Privacy MaskUse the cursor button j or l to select SET for SET buttonAbout the Position screen Privacy Mask Setting Privacy MaskPassword screen will appear Password setting¤¤¤ To move the cursor to the next * digitPassword changes Password Lock cancellationFor use when Password Lock is on Password NEW Password screen will appearFocus setting Lens Setting LensSetting the manual focus Manu Setting the autofocus Auto Lens Setting LensHigh High sensitivity focusing LOW Low sensitivity focusing Button Zoom Setting screen will appear Zoom settingEL Zoom Electronic zoom magnification setting Available settings OFF, x2, x4, x8, x16 16 powerIris Auto item Sense UP activated Mirror SettingOFF Normal image View Setting Item Flow About creating image setting files in View Setting View Setting Item FlowFunction is set Iris setting View SettingAutoiris setting Auto BLC Setting screen will appear View SettingBLC Setting Size screen will appear BLC Setting Position screen will appearBLC Window Weighting screen will appear Example of setting the mask in the center weighting position Then press the SET button Use the cursor button j l d c to move the cursor toAvailable settings OFF, x2, x4, x8, x16 Sense UP setting Level settingIris Setting screen will appear Manual iris settingSets electronic iris ON/OFF, lens aperture and iris level View Setting 1 screen will appear White Balance adjustmentAvailable methods ATW Auto trace white balance AWC One-push automatic white balanceWhite balance additional settings ATW setting White balance additional settings MWB settingMWB Setting screen will appear Use the same steps to place addition masks as needed White balance additional settings AWC setting Fast shutter speed Short mode setting Electronic Shutter settingAvailable settings 50, 120, 250, 500, 1000, 2000, 4000 Iris Auto item Sense UP activated or Manu item El on Slow shutter speed Long mode settingMotion Setting screen will appear and SET for Size will Motion detector settingSelect ON. Then press the SET button BlinkingV2, H2 V1, H1V1, H2 V2, H1Finishing motion pattern setting Motion Masking settingPattern When necessary, adjust the following settings Sensitivity settingDetected motion confirmation mode Demo Sensitivity screen will appearThis item is set in the Motion Setting screen Interval settingAlarm Sign setting Vertical directions Profile compensation setting ApertureSet the horizontal profile compensation Set the vertical profile compensationSets AGC to on or OFF and adjusts the gain Automatic gain control AGC settingGain Setting screen will appear, and 0dB will be blinking Gamma correction setting Control setting Option SettingRS-485 Setting screen will appear Available settings 19200, 9600, 4800Alarm setting Alarm input setting Alarm Option SettingAddress setting Alarm duration setting Duration Motion sensor input setting MotionOFF Does not output a motion sensor alarm Set the duration for the following alarm input receptionAlarm output setting Alarm OUT Option Setting See Menu FlowMenu Flow Electronic zoom SpecificationsDimensions Specifications