Sanyo vcc-zm300p Option Setting, Alarm setting Alarm input setting Alarm, Address setting

Page 48

OPTION SETTING

English

1

MAIN MENU

 

2

 

LANGUAGE

SET

 

CAMERA ID

OFF

 

 

SYNC

INT

 

 

PRIVACY MASK

SET

 

LENS

SET

 

MIRROR

OFF

 

 

VIEW SETTING

1

 

OPTION

SET

 

OPTION

 

CONTROL

485

ADDRESS

0

 

ALARM

SET

ALARM setting

A Alarm input setting (ALARM IN)

Make the following settings for alarm detection.

Connect the external alarm switch to the alarm input terminal on the back of the camera.

ADDRESS setting

1Use the cursor button (j or l) to move the cursor to

OPTION, then press the SET button. The OPTION screen will appear.

1

MAIN MENU

 

2

 

LANGUAGE

SET

 

CAMERA ID

OFF

 

 

SYNC

INT

 

 

PRIVACY MASK

SET

 

LENS

SET

 

MIRROR

OFF

 

 

VIEW SETTING

1

 

OPTION

SET

 

OPTION

 

CONTROL

485

ADDRESS

0

 

ALARM

SET

Note: The PRESET ON setting cannot be used when OPTION settings are in use.

2Use the cursor button (j or l) to move the cursor to ADDRESS, and then use the cursor button (d or c) to select the address.

Available settings: 0 (d) ~ 127 (c)

To close the menu screen or return to the previous screen, select BACK or END for MENU and press the SET button.

1Use the cursor button (j or l) to move the cursor to

OPTION, then press the SET button. The OPTION screen will appear.

Note: The PRESET ON setting cannot be used when OPTION settings are in use.

2Use the cursor button (j or l) to move the cursor to

ALARM, then press the SET button. The ALARM SETTING screen will appear.

3Use the cursor button (d or c) to select POLARITY between “NO” and “NC”.

Available settings:

NO: Normal open (Normally open so closed condition is detected as input.)

NC: Normal closed (Normally closed so open condition is detected as input.)

47

Image 48
Contents VCC-ZM300P Propos de ce manuelContents Main Features AccessoriesPrecautions Parts Names and Functions Parts Names and Functions Power supply choices ConnectionsAC 24 V connection DC 12 V connectionConnections Coaxial cable type and maximum lengthSetting to ON, then press the SET button DISPLAYING/CLOSING the Menu ScreenSub-menu screen Cursor button SET buttonMenu Item Flow and Menu Operation Language Setting Language screen will appearInterface language becomes French Camera ID Setting Camera ID setting Example Setting the Camera ID to CAMID CAM 1 ???????????? Camera ID screenSync Setting Sync Camera ID SettingPower source synchronization L-L setting Privacy Mask Setting Privacy Mask Mask settingUse the cursor button j or l to select SET for SET buttonPrivacy Mask Setting Privacy Mask About the Position screenPassword setting Password screen will appear¤¤¤ To move the cursor to the next * digitPassword Lock cancellation Password changesFor use when Password Lock is on Password NEW Password screen will appearLens Setting Lens Focus settingSetting the manual focus Manu Lens Setting Lens Setting the autofocus AutoHigh High sensitivity focusing LOW Low sensitivity focusing Button Zoom setting Zoom Setting screen will appearEL Zoom Electronic zoom magnification setting Available settings OFF, x2, x4, x8, x16 16 powerMirror Setting Iris Auto item Sense UP activatedOFF Normal image View Setting Item Flow View Setting Item Flow About creating image setting files in View SettingFunction is set View Setting Iris settingAutoiris setting Auto View Setting BLC Setting screen will appearBLC Setting Position screen will appear BLC Setting Size screen will appearBLC Window Weighting screen will appear Example of setting the mask in the center weighting position Use the cursor button j l d c to move the cursor to Then press the SET buttonSense UP setting Level setting Available settings OFF, x2, x4, x8, x16Manual iris setting Iris Setting screen will appearSets electronic iris ON/OFF, lens aperture and iris level White Balance adjustment View Setting 1 screen will appearAvailable methods ATW Auto trace white balance AWC One-push automatic white balanceWhite balance additional settings MWB setting White balance additional settings ATW settingMWB Setting screen will appear Use the same steps to place addition masks as needed White balance additional settings AWC setting Electronic Shutter setting Fast shutter speed Short mode settingAvailable settings 50, 120, 250, 500, 1000, 2000, 4000 Slow shutter speed Long mode setting Iris Auto item Sense UP activated or Manu item El onMotion detector setting Motion Setting screen will appear and SET for Size willSelect ON. Then press the SET button BlinkingV1, H1 V2, H2V1, H2 V2, H1Motion Masking setting Finishing motion pattern settingPattern Sensitivity setting When necessary, adjust the following settingsDetected motion confirmation mode Demo Sensitivity screen will appearInterval setting This item is set in the Motion Setting screenAlarm Sign setting Profile compensation setting Aperture Vertical directionsSet the horizontal profile compensation Set the vertical profile compensationAutomatic gain control AGC setting Sets AGC to on or OFF and adjusts the gainGain Setting screen will appear, and 0dB will be blinking Gamma correction setting Option Setting Control settingRS-485 Setting screen will appear Available settings 19200, 9600, 4800Option Setting Alarm setting Alarm input setting AlarmAddress setting Motion sensor input setting Motion Alarm duration setting DurationOFF Does not output a motion sensor alarm Set the duration for the following alarm input receptionAlarm output setting Alarm OUT Option Setting Menu Flow SeeMenu Flow Specifications Electronic zoomSpecifications Dimensions