Sanyo vcc-zm300p instruction manual Gamma correction setting, Button

Page 46

VIEW SETTING

GGAMMA correction setting

In addition to turning gamma correction ON or OFF, contrast sensitivity can be boosted at 2 levels.

English

1MAIN MENU

LANGUAGE

SET

CAMERA ID

OFF

 

SYNC

INT

 

PRIVACY MASK

SET

LENS

SET

MIRROR

OFF

 

VIEW SETTING

1

OPTION

SET

PRESET

OFF

 

MENU

END

 

2VIEW SETTING 1

IRIS

AUTO

WHITE BALANCE

ATW

SHUTTER

LONG ‚

MOTION

OFF

 

APERTURE

ON

AGC

ON

GAMMA

ON

 

PRESET

OFF

 

MENU

BACK

 

1Use the cursor button (j or l) to move the cursor to

VIEW SETTING, then press the SET button. (Ex: 1) The VIEW SETTING 1 screen will appear.

2Use the cursor button (j or l) to move the cursor to ON for GAMMA, then use the cursor button (d or c) to select the gamma correction.

Available settings:

OFF: No gamma correction

ON: Gamma correction (γ = 0.45)

SMART 1: Correction 1

SMART 2: Correction 2 (improves contrast for dark locations)

Note: When using SMART 1 or SMART 2, the target object may be too bright, so determine which setting is better for the target object.

To close the menu screen or return to the previous screen, select BACK or END for MENU and press the SET

45 button.

Image 46
Contents VCC-ZM300P Propos de ce manuelContents Main Features AccessoriesPrecautions Parts Names and Functions Parts Names and Functions AC 24 V connection Power supply choicesConnections DC 12 V connectionConnections Coaxial cable type and maximum lengthSub-menu screen Setting to ON, then press the SET buttonDISPLAYING/CLOSING the Menu Screen Cursor button SET buttonMenu Item Flow and Menu Operation Language screen will appear Language SettingInterface language becomes French ID CAM 1 ???????????? Camera ID SettingCamera ID setting Example Setting the Camera ID to CAM Camera ID screenCamera ID Setting Sync Setting SyncPower source synchronization L-L setting Use the cursor button j or l to select SET for Privacy Mask Setting Privacy MaskMask setting SET buttonPrivacy Mask Setting Privacy Mask About the Position screen¤¤¤ Password settingPassword screen will appear To move the cursor to the next * digitFor use when Password Lock is on Password Lock cancellationPassword changes Password NEW Password screen will appearFocus setting Lens Setting LensSetting the manual focus Manu Setting the autofocus Auto Lens Setting LensHigh High sensitivity focusing LOW Low sensitivity focusing Button EL Zoom Electronic zoom magnification setting Zoom settingZoom Setting screen will appear Available settings OFF, x2, x4, x8, x16 16 powerIris Auto item Sense UP activated Mirror SettingOFF Normal image View Setting Item Flow About creating image setting files in View Setting View Setting Item FlowFunction is set Iris setting View SettingAutoiris setting Auto View Setting BLC Setting screen will appearBLC Setting Size screen will appear BLC Setting Position screen will appearBLC Window Weighting screen will appear Example of setting the mask in the center weighting position Use the cursor button j l d c to move the cursor to Then press the SET buttonSense UP setting Level setting Available settings OFF, x2, x4, x8, x16Iris Setting screen will appear Manual iris settingSets electronic iris ON/OFF, lens aperture and iris level Available methods ATW Auto trace white balance White Balance adjustmentView Setting 1 screen will appear AWC One-push automatic white balanceWhite balance additional settings ATW setting White balance additional settings MWB settingMWB Setting screen will appear Use the same steps to place addition masks as needed White balance additional settings AWC setting Fast shutter speed Short mode setting Electronic Shutter settingAvailable settings 50, 120, 250, 500, 1000, 2000, 4000 Slow shutter speed Long mode setting Iris Auto item Sense UP activated or Manu item El onSelect ON. Then press the SET button Motion detector settingMotion Setting screen will appear and SET for Size will BlinkingV1, H2 V1, H1V2, H2 V2, H1Finishing motion pattern setting Motion Masking settingPattern Detected motion confirmation mode Demo Sensitivity settingWhen necessary, adjust the following settings Sensitivity screen will appearInterval setting This item is set in the Motion Setting screenAlarm Sign setting Set the horizontal profile compensation Profile compensation setting ApertureVertical directions Set the vertical profile compensationSets AGC to on or OFF and adjusts the gain Automatic gain control AGC settingGain Setting screen will appear, and 0dB will be blinking Gamma correction setting RS-485 Setting screen will appear Option SettingControl setting Available settings 19200, 9600, 4800Alarm setting Alarm input setting Alarm Option SettingAddress setting OFF Does not output a motion sensor alarm Motion sensor input setting MotionAlarm duration setting Duration Set the duration for the following alarm input receptionAlarm output setting Alarm OUT Option Setting Menu Flow SeeMenu Flow Specifications Electronic zoomSpecifications Dimensions