Sanyo XHS2432, XHS3632, XHS4232, THS4232, THS3632, THS2432 Auto, Heat, Cool, Fan, Hour OFF Timer

Page 10

 

Remote Control Unit (continued)

 

 

Program button

For details, see “Setting theTimer”.

 

Press this button to select the mode you want to program.

 

 

TIMER SELECT button

No display : The timer does not operate.

 

 

: The air conditioner stops at the set time.

 

 

 

 

: The air conditioner starts at the set time.

 

 

: The air conditioner stops and starts, or starts and stops, at the

 

 

set times every day.

 

 

MODE selector button

Use this button to select the AUTO, HEAT, COOL or FAN mode.

(AUTO)

 

: When this setting is selected, the air conditioner calculates the

 

 

difference between the thermostat setting and the room temperature

 

 

and automatically switches to the “COOL” or “HEAT” mode as

 

 

appropriate.

(HEAT)

 

: The air conditioner makes the room warmer.

(COOL)

 

: The air conditioner makes the room cooler.

(FAN)

 

: The air conditioner works only as a circulation fan.

 

 

FLAP button

Press this button to select the sweep function, which moves the flap up and

 

down automatically.

 

 

: The flap moves up and down automatically.

 

 

 

FAN SPEED selector button

 

: The air conditioner automatically decides the fan speeds.

 

 

: High fan speed

 

 

: Medium fan speed

 

 

: Low fan speed

 

 

 

1 HR. TIMER button

 

: When you press this button, regardless of whether the unit is

(1-HOUR OFF TIMER)

 

operating or stopping, the unit operates for one hour and then

 

 

shuts down.

 

 

ACL button (ALL CLEAR)

Puts the remote control unit into pre-operation status. Always press this

 

button after replacing the batteries.

 

 

ADDRESS switch

Change the address switch to prevent mixing of signals from remote control

 

units when two Sanyo air conditioners are installed next to each other.

 

Normally, the remote control address switch is set to A. For the second

 

indoor unit, both addresses of the remote control unit and the indoor unit

 

must be changed. The second remote control unit address must be changed

 

to B by breaking off the tab ”A“. And the second indoor unit address must

 

be changed from 1 to 2 by switching the slide switch in the indoor unit. For

 

more information, please contact the dealer where you made the purchase.

Normally, the tabs on the remote control unit should not be bent.

SENSOR button When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly.

NOTE If the remote control is located near a heat source, such as a space heater or in direct sunlight, press the SENSOR button to switch to the sensor on the indoor unit.

NOTE

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

10

OI-212-10EG

Image 10 Contents
Split System Heat Pump Features Contents Product InformationSafety Instructions Installation LocationElectrical Requirements Names of Parts Outdoor condensing unit Lamp Control Operation Timer Standby Recessed type Ceiling-mounted type Recessed type Ceiling-mounted type Operation selectorUnit Display and Operation Selector Remote ControlIndoor Unit OFF Remote Control Unit Heat Hour OFF TimerAuto CoolRemote Control Unit Installation Position Using the Remote Control UnitHow to Install Batteries Do notWhen using the remote control unit Using the Remote Control UnitMounting the Remote Control Unit Securing the remote control unit to prevent theftStep Operation with the Remote Control UnitAutomatic Operation Press the ON/OFF operation buttonManual Operation Operation with the Remote Control UnitStep Adjusting the Fan Speed FAN SpeedFan Only Night Setback Mode Night Setback Mode is used for saving energyNight Setback Set Temperature Pressing 30 minButton Heating Mode TimeHow to set the present time Setting theTimerRemote Control Unit Special RemarksSetting the Timer How to set a program for daily ON/OFF operationSetting procedure Using the 1-Hour OFFTimerHour OFF Timer Operation Together with the Program Timer Cancellation procedureOperation without the Remote Control Unit Adjusting the Airflow DirectionCooling Care and Cleaning Latch Safety string Air intake grille Bolt screw Air filterCare and Cleaning How to remove the filter Ceiling-mounted typeTips for Energy Saving TroubleshootingShould the power fail while the unit is running Operating RangeSanyo Canada Inc CanadaSanyo Fisher Company Division of Sanyo North America Corporation
Related manuals