Operation with the Remote Control Unit (continued)
NOTE
3.Adjusting the Fan Speed
A.Automatic
Cooling mode:
Heating mode:
NOTE
B. Manual
·Choose the best position in the room for the remote control unit, which also acts as the sensor for room comfort and transmits the operating instructions. Once you've found this best position, always keep the remote control unit there.
·This appliance has a
Simply set the FAN SPEED selector button to the position.
A microcomputer in the air conditioner controls the fan speed automatically
when the mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to a suitable level.
When difference between |
|
room temperature and set | FAN SPEED |
temperature is |
|
|
|
4 °F and over | High |
|
|
Between 4 °F and 2 °F | Medium |
|
|
Below 2 °F | Low |
|
|
When difference between |
|
room temperature and set | FAN SPEED |
temperature is |
|
|
|
4 °F and over | High |
|
|
Below 4 °F | Medium |
|
|
The above table assumes that the sensor in the remote control is being used. If the sensor in the indoor unit is being used (the indicator is on), actual operation may differ slightly from the operation described in the table.
(Refer to ``SENSOR button'' on page 10.)
If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired by following STEP 4 on page 14. [ , , or ]
15 |