Operation with the Remote Control Unit (continued)

NOTE

3.Adjusting the Fan Speed

A.Automatic

Cooling mode:

Heating mode:

NOTE

B. Manual

·Choose the best position in the room for the remote control unit, which also acts as the sensor for room comfort and transmits the operating instructions. Once you've found this best position, always keep the remote control unit there.

·This appliance has a built-in 3-minute time delay circuit to ensure reliable operation. When the operation button is pressed, the compressor will start running within three minutes. In the event of power failure, the unit will stop. When the power is restored, the unit will restart automatically after three minutes.

Simply set the FAN SPEED selector button to the position.

A microcomputer in the air conditioner controls the fan speed automatically

when the mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microcomputer which then automatically switches the fan speed to a suitable level.

When difference between

 

room temperature and set

FAN SPEED

temperature is

 

 

 

4 °F and over

High

 

 

Between 4 °F and 2 °F

Medium

 

 

Below 2 °F

Low

 

 

When difference between

 

room temperature and set

FAN SPEED

temperature is

 

 

 

4 °F and over

High

 

 

Below 4 °F

Medium

 

 

The above table assumes that the sensor in the remote control is being used. If the sensor in the indoor unit is being used (the indicator is on), actual operation may differ slightly from the operation described in the table.

(Refer to ``SENSOR button'' on page 10.)

If you want to adjust fan speed manually during operation, just set the FAN SPEED selector button as desired by following STEP 4 on page 14. [ , , or ]

OI-212-15EG

15

Image 15 Contents
Split System Heat Pump Features Product Information ContentsInstallation Location Safety InstructionsElectrical Requirements Outdoor condensing unit Names of PartsRecessed type Ceiling-mounted type Operation selector Operation Timer StandbyRecessed type Ceiling-mounted type Lamp ControlRemote Control Unit Display and Operation SelectorIndoor Unit OFF Remote Control Unit Cool Hour OFF TimerAuto Heat Do not Using the Remote Control Unit How to Install Batteries Remote Control Unit Installation PositionSecuring the remote control unit to prevent theft Using the Remote Control UnitMounting the Remote Control Unit When using the remote control unitPress the ON/OFF operation button Operation with the Remote Control UnitAutomatic Operation StepOperation with the Remote Control Unit Manual OperationStep FAN Speed Adjusting the Fan SpeedNight Setback Mode is used for saving energy Fan Only Night Setback ModeTime Set Temperature Pressing 30 minButton Heating Mode Night SetbackSpecial Remarks Setting theTimerRemote Control Unit How to set the present timeHow to set a program for daily ON/OFF operation Setting the TimerCancellation procedure Using the 1-Hour OFFTimerHour OFF Timer Operation Together with the Program Timer Setting procedureAdjusting the Airflow Direction Operation without the Remote Control UnitCooling Latch Safety string Air intake grille Bolt screw Air filter Care and CleaningHow to remove the filter Ceiling-mounted type Care and CleaningOperating Range TroubleshootingShould the power fail while the unit is running Tips for Energy SavingDivision of Sanyo North America Corporation CanadaSanyo Fisher Company Sanyo Canada Inc