Sanyo THS3632 Using the 1-Hour OFFTimer, Hour OFF Timer Operation Together with the Program Timer

Page 20

1.1-Hour OFF Timer

NOTE

2.Operation Together with the Program Timer

Using the 1-Hour OFFTimer

This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.

Theindicator in the display indicates that this function is operating.

Setting procedure:

Regardless of whether the unit is operating or stopped, press the 1 HR.TIMER button.

appears in the display.

Cancellation procedure:

Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.The 1-HourTimer function is now cancelled and the unit operates normally.

If, while the 1-Hour Timer function is operating, the 1 HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.

The 1-Hour OFFTimer setting is given priority over the daily program setting.

It is not possible to use the OFFTimer and 1-Hour OFFTimer together. Whichever function is set last takes precedence.

If the 1 HR.TIMER button is pressed while theTIMER OFF function operates, OFFTimer is cancelled and the unit will stop operating one hour later.

20

OI-212-20EG

Image 20
Contents Split System Heat Pump Features Contents Product InformationElectrical Requirements Installation LocationSafety Instructions Names of Parts Outdoor condensing unitOperation Timer Standby Recessed type Ceiling-mounted typeLamp Control Recessed type Ceiling-mounted type Operation selectorIndoor Unit Remote ControlUnit Display and Operation Selector OFF Remote Control Unit Hour OFF Timer AutoHeat CoolUsing the Remote Control Unit How to Install BatteriesRemote Control Unit Installation Position Do notUsing the Remote Control Unit Mounting the Remote Control UnitWhen using the remote control unit Securing the remote control unit to prevent theftOperation with the Remote Control Unit Automatic OperationStep Press the ON/OFF operation buttonStep Operation with the Remote Control UnitManual Operation Adjusting the Fan Speed FAN SpeedFan Only Night Setback Mode Night Setback Mode is used for saving energySet Temperature Pressing 30 min Button Heating ModeNight Setback TimeSetting theTimer Remote Control UnitHow to set the present time Special RemarksSetting the Timer How to set a program for daily ON/OFF operationUsing the 1-Hour OFFTimer Hour OFF Timer Operation Together with the Program TimerSetting procedure Cancellation procedureCooling Adjusting the Airflow DirectionOperation without the Remote Control Unit Care and Cleaning Latch Safety string Air intake grille Bolt screw Air filterCare and Cleaning How to remove the filter Ceiling-mounted typeTroubleshooting Should the power fail while the unit is runningTips for Energy Saving Operating RangeCanada Sanyo Fisher CompanySanyo Canada Inc Division of Sanyo North America Corporation
Related manuals
Manual 106 pages 21.57 Kb

THS2432, KHS3632, THS3632, THS4232, XHS3632 specifications

The Sanyo XHS4232, XHS2432, KHS2432, XHS3632, and THS4232 are exemplary models in Sanyo's lineup of high-performance air conditioning systems. These units are designed to offer efficient climate control solutions for various residential and commercial applications, featuring advanced technologies that ensure comfort and energy savings.

The Sanyo XHS4232 and XHS2432 models are particularly known for their inverter technology, which allows for variable speed operation. This technology adjusts the compressor speed according to the cooling demand, resulting in significant energy savings and quieter operation. Both models boast high Seasonal Energy Efficiency Ratio (SEER) ratings, making them environmentally friendly choices that contribute to lower utility bills.

The KHS2432 model combines energy efficiency with durable construction. It features streamlined designs with robust materials to withstand various environmental conditions. The KHS2432 also incorporates a smart control system that can be operated via remote, enabling users to manage their climate from different locations.

Moving to the XHS3632, this model is designed for larger spaces and offers a higher cooling capacity. It benefits from an enhanced air circulation system that promotes even temperature distribution throughout the area. This model includes an air purification feature that filters dust and allergens, ensuring a healthier indoor environment.

Lastly, the THS4232 stands out with its advanced smart thermostat integration, which allows users to program schedules and monitor their energy usage. The THS4232 offers a unique feature set tailored to modern smart homes, providing convenience and control through mobile apps. Its compatibility with various smart home systems extends its versatility, making climate management easier than ever.

All these models come equipped with features such as quiet operation modes, user-friendly interfaces, and eco-friendly refrigerants. Their designs focus on energy efficiency and user comfort while maintaining reliability and performance.

In summary, the Sanyo XHS4232, XHS2432, KHS2432, XHS3632, and THS4232 represent significant advancements in air conditioning technology, offering impressive features like inverter technology, smart controls, and air purification systems that cater to the needs of today's consumers. These systems not only ensure optimal performance but also promote energy efficiency and environmental sustainability.