Sanyo RCS-SH80UG, TM-SH80UG Filter lamp This lamp lights when the filter needs cleaning

Page 26

2

Operation Controller with Receiver (Separated from Indoor Unit) for K and U Types

A: Operation controller

B: Remote control receiver

C: ON/OFF operation button

D: SWEEP button

E: SERVICING switches

F: Switch

G: ADDRESS switch

H: OPERATION lamp

I: TIMER lamp

J: STANDBY lamp

K: FILTER lamp

A: Operation controller

You can operate this air conditioner using the

(separated from indoor unit)

operation controller without the wireless remote controller.

B:Remote control receiver This section picks up infrared signals from the wireless remote controller (transmitter).

C:ON/OFF operation button This button is for turning the air conditioner on and off (automatically setting cooling or heating operation).

D: SWEEP button

Use this button to make the airflow direction sweep up and down

 

 

 

automatically.

 

 

 

 

E: SERVICING switches

These switches are used only when servicing the air conditioner.

 

 

 

Do not use these SERVICING switches for normal operation.

 

 

 

 

 

 

 

 

 

 

F: Switch

Usually set this switch in to the NORMAL position.

 

 

 

 

G: ADDRESS switch

When operating the air conditioner by using the wireless remote controller, be

 

 

 

sure to match the number on this switch with the number set on the wireless

 

 

 

remote controller. Otherwise, the remote control will not work.

 

 

 

 

H: OPERATION lamp

This lamp lights when the appliance is turned on.

 

 

 

 

I: TIMER lamp

This lamp lights when the system is being controlled by the timer.

 

 

 

 

J: STANDBY lamp

When the unit is in the heating standby condition, the STANDBY lamp lights.

 

 

 

 

K: FILTER lamp

This lamp lights when the filter needs cleaning.

 

 

 

 

 

 

 

Turning off the ON/OFF operation button does not

 

 

 

disconnect the power. Use the main power switch to turn off

 

 

 

the power completely.

2 - 6

OI-404-02 - 6EG

Image 26
Contents TM-SH80UG Page RCS-SH80UG Product Information ContentsAlert Symbols Power mains Installation LocationSafety Instructions Electrical RequirementsNames of Parts Remote Cotrol Unit OFF Timer Cool mode and dry mode, when the flaps are set in aTimer SET button OFF Cycle TimerOI-432-01 7EG Description Display Remote Control UnitBF C I J M Operation StepHorizontal directions manual Adjusting the Airflow DirectionSemi-concealed type Way type Vertical vanes to the left or rightWall mounted type K Vertical directions automatic Concealed duct type UHow it works Should the power fail while the unit is runningSpecial Remarks Heating performance DefrostingSetting the Timer OFF cycle TimerONOperation Indication IndicationOperation Care and Cleaning Air filter How to clean the filterAir filter Grille Bolt screw How to remove the filterCleaning, be sure to attach the two bolt screws Grille will open downwardTrouble Possible Cause Remedy TroubleshootingTips for Energy Saving Obstructed, the unit will not work well, and may be damagedPage RCS-SH80UA.WL RCS-BH80UA.WL Product or property damage This symbol refers to a hazard or unsafeInjury or death Your dealer for help Operation Timer Unit Display and Operation Controller for X and T TypesServicing switches SwitchAddress switch Sweep buttonFilter lamp This lamp lights when the filter needs cleaning Using the Wireless Remote Controller How to Install BatteriesUsing the Wireless Remote Controller Rear plateTransmitter Sensor Display Only for heat pump typeTransmitter Setting addresses of indoor units for remote controller ALL ClearDisplay Wireless Remote Controller OI-404-02 13EG Operation without the Wireless Remote Controller Press the ON/OFF operation button againAddress switch setting Timer OFF cycleExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Programmed operation Indicator Holiday indicatorNames and Functions of Controls Proper Operation Operation of the programmable weekly timerHow to set the present time Turning onHow to set the day Setting the day How to set program operations Press the Program buttonPress the Program button to complete the program setting Programming shown below will cause Error setting Following examples will not cause Error settingPress the Check button Programmed operation times of the day the indicator pointsCheck How to change programmed operation times How to clear a program of a dayTo clear a programmed holiday Explanation of the operationTo restart operation Power failureAdditional Information Ex Weekly operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG Ventilation Central Ctrl How to Use the System ControllerALL/ZONE/GR ALLCool or Only for heat pump type Temperature range 62 ~ 80 FOnly for heat pump type Temperature range 60 ~ 78 F Heat or FANFollows Do not use the SET button for normal operationDisplay Description Stop How to start group operationStop Power How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.