Sanyo TM-SH80UG Flap button, Cool mode and dry mode, when the flaps are set in a, OFF Timer

Page 8

1

 

 

 

Remote Control Unit (continued)

 

 

F: FILTER reset button

Use this button to reset the filter sign . The air conditioner has a timer

 

 

 

for the filter and informs you when the filter needs cleaning.

 

 

G: CHECK button

This button is used only when servicing the air conditioner.

 

 

 

Do not use the CHECK button for normal operation.

 

 

 

 

 

 

 

H: UNIT button

 

 

 

 

When more than one indoor unit is connected, this button is used to

 

 

 

 

 

 

 

 

 

 

 

 

 

select a unit when adjusting the airflow direction.

 

 

 

 

 

If no unit is selected, the airflow direction of all units can be adjusted

 

 

 

 

 

concurrently using the FLAP button.

 

 

 

 

 

 

 

 

 

 

I: FLAP button

( )

1. Use this button to set the airflow direction to a specific angle.

 

 

 

 

 

The airflow direction (

) is displayed on the remote control unit.

 

 

 

 

 

 

Operation mode

 

Number of airflow direction settings

 

 

 

 

 

 

(COOL) or

 

(DRY)

 

3

 

 

 

 

 

 

 

(HEAT) or

(FAN)

5

 

 

 

 

 

 

 

(AUTO)

 

 

3

 

 

 

 

 

 

 

Cooling mode:

 

 

 

 

 

 

 

Heating mode:

5

 

 

 

 

 

 

In the cool mode and dry mode, when the flaps are set in a

 

 

 

 

 

 

 

 

 

 

 

downward position, condensation may form and drip around

 

 

 

 

 

 

 

 

 

 

 

the vent.

 

 

 

 

 

Do not move the flap with your hands.

 

NOTE

 

 

This function is available only for models X and T.

(

)

 

 

 

2. Use this button to make the airflow direction sweep up and down

 

 

 

 

automatically.

 

 

 

 

 

Press this button several times until the (

) symbol appears on

 

 

 

 

the display.

 

 

 

 

 

This function is available only for models X, T and K.

.

NOTE

 

 

 

 

 

 

 

 

J: TIMER SET button

 

 

Use this button while the unit is operating to switch between timer

 

 

 

 

settings:

 

(OFF Timer)

 

:The air conditioner stops after the length of time set.

(OFF Cycle Timer)

 

:The air conditioner after the same set time every time.

(ON Timer)

 

:The air conditioner starts after the length of time set.

 

 

 

 

 

 

 

 

 

K: Time setting buttons

 

 

 

:Press this button to increase the time.

 

:Press this button to decrease the time.

L: SET button

Use this button to set the timer.

 

M: CL button

Use this button to clear the timer setting.

 

 

 

N: Temperature sensor of the

While the temperature sensor of the indoor unit usually detects ambient

remote controller

temperatures, it is also possible to detect temperatures around the

 

remote controller. For the detail of this functionality, consult your dealer.

 

(Do not use this functionality for group operation.)

 

 

 

O: VENTILATION button

Use this button when you installed a fan available in the market.

 

Pressing this button turns on and off the fan.

 

 

When turning off the air conditioner, the fan will be also turned off.

 

While the fan is operating,

will appear in the display. If

is

 

displayed when pressing the ventilation button, no fans are installed.

1 - 6

OI-432-01 - 6EG

Image 8
Contents TM-SH80UG Page RCS-SH80UG Product Information ContentsAlert Symbols Installation Location Safety InstructionsPower mains Electrical RequirementsNames of Parts Remote Cotrol Unit Cool mode and dry mode, when the flaps are set in a Timer SET buttonOFF Timer OFF Cycle TimerOI-432-01 7EG Description Display Remote Control UnitBF C I J M Operation StepAdjusting the Airflow Direction Semi-concealed type Way typeHorizontal directions manual Vertical vanes to the left or rightWall mounted type K Vertical directions automatic Concealed duct type UShould the power fail while the unit is running Special RemarksHow it works Heating performance DefrostingSetting the Timer OFF cycle TimerONOperation Indication IndicationOperation Care and Cleaning Air filter How to clean the filterGrille Bolt screw How to remove the filter Cleaning, be sure to attach the two bolt screwsAir filter Grille will open downwardTroubleshooting Tips for Energy SavingTrouble Possible Cause Remedy Obstructed, the unit will not work well, and may be damagedPage RCS-SH80UA.WL RCS-BH80UA.WL Product or property damage This symbol refers to a hazard or unsafeInjury or death Your dealer for help Operation Timer Unit Display and Operation Controller for X and T TypesSwitch Address switchServicing switches Sweep buttonFilter lamp This lamp lights when the filter needs cleaning Using the Wireless Remote Controller How to Install BatteriesUsing the Wireless Remote Controller Rear plateTransmitter Sensor Display Only for heat pump typeTransmitter Setting addresses of indoor units for remote controller ALL ClearDisplay Wireless Remote Controller OI-404-02 13EG Operation without the Wireless Remote Controller Press the ON/OFF operation button againAddress switch setting Timer OFF cycleExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Programmed operation Indicator Holiday indicatorNames and Functions of Controls Operation of the programmable weekly timer How to set the present timeProper Operation Turning onHow to set the day Setting the day How to set program operations Press the Program buttonPress the Program button to complete the program setting Programming shown below will cause Error setting Following examples will not cause Error settingPress the Check button Programmed operation times of the day the indicator pointsCheck How to change programmed operation times How to clear a program of a dayTo clear a programmed holiday Explanation of the operationPower failure Additional InformationTo restart operation Ex Weekly operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG How to Use the System Controller ALL/ZONE/GRVentilation Central Ctrl ALLOnly for heat pump type Temperature range 62 ~ 80 F Only for heat pump type Temperature range 60 ~ 78 FCool or Heat or FANFollows Do not use the SET button for normal operationDisplay Description Stop How to start group operationStop Power How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.