How to start group operation

To start group operation

2

1

9

8

4

Stop

3

5

6

7

4

Power

Turn the power supply switch on more than 5 hours before starting operation.

1 Press the SELECT button and select GROUP.

2

 

 

Select the ZONE No. including the group to be operated by pressing ZONE button.

3

 

 

Select the GROUP No. to be operated by pressing GROUP select buttons

.

 

 

 

 

 

4

 

 

Press the ON button.

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

Set the operation mode by pressing the MODE button.

 

 

 

 

 

 

6

 

 

Set the desired temperature by pressing one of the temperature setting buttons

.

 

 

 

 

 

7

 

 

Set the desired fan speed by pressing the FAN SPEED button.

 

 

 

 

 

 

8

 

 

Set the airflow direction to a specific angle or sweep mode.

 

 

 

 

 

 

 

9

 

 

By pressing

, select your desired setting.

 

 

 

 

Individual: Controls with the remote controller are possible.

 

 

 

 

Central 1: Individual ON/OFF operation with the remote controller is inhibited.

 

 

 

 

Central 2: Individual ON/OFF, MODE, and Temp. setting operations with the remote

 

 

 

 

 

 

controller are inhibited.

 

 

 

 

Central 3: Individual MODE and Temp. setting operations with the remote controller are

 

 

 

 

 

 

inhibited.

 

 

 

 

Central 4: Individual MODE operation with the remote controller is inhibited.

 

 

 

 

• Under Central/Individual settings other than listed above, “CENTRAL” is displayed.

 

 

 

AUTO

 

Depending on the difference between the temperature setting and the room temperature,

Operation

 

heating and cooling alternate automatically so that a uniform room temperature is maintained.

 

 

 

 

Stop

 

Confirming the GROUP No. to be selected, press the OFF button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

The flap setting can be performed only for units that have no remote

 

 

 

 

 

 

controllers.

 

 

 

 

 

 

 

 

 

4 - 8

OI-432-04 - 8EG

Image 60
Contents TM-SH80UG Page RCS-SH80UG Contents Alert SymbolsProduct Information Installation Location Safety InstructionsPower mains Electrical RequirementsNames of Parts Remote Cotrol Unit Cool mode and dry mode, when the flaps are set in a Timer SET buttonOFF Timer OFF Cycle TimerOI-432-01 7EG Display Remote Control Unit BF C I J MDescription Operation StepAdjusting the Airflow Direction Semi-concealed type Way typeHorizontal directions manual Vertical vanes to the left or rightWall mounted type K Vertical directions automatic Concealed duct type UShould the power fail while the unit is running Special RemarksHow it works Heating performance DefrostingSetting the Timer OFF cycle TimerONIndication OperationOperation Indication Care and Cleaning Air filter How to clean the filterGrille Bolt screw How to remove the filter Cleaning, be sure to attach the two bolt screwsAir filter Grille will open downwardTroubleshooting Tips for Energy SavingTrouble Possible Cause Remedy Obstructed, the unit will not work well, and may be damagedPage RCS-SH80UA.WL RCS-BH80UA.WL This symbol refers to a hazard or unsafe Injury or deathProduct or property damage Your dealer for help Operation Timer Unit Display and Operation Controller for X and T TypesSwitch Address switchServicing switches Sweep buttonFilter lamp This lamp lights when the filter needs cleaning Using the Wireless Remote Controller How to Install BatteriesUsing the Wireless Remote Controller Rear plateTransmitter Sensor Display Only for heat pump typeTransmitter Setting addresses of indoor units for remote controller ALL ClearDisplay Wireless Remote Controller OI-404-02 13EG Operation without the Wireless Remote Controller Press the ON/OFF operation button againAddress switch setting Timer OFF cycleExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Indicator Holiday indicator Names and Functions of ControlsProgrammed operation Operation of the programmable weekly timer How to set the present timeProper Operation Turning onHow to set the day Setting the day How to set program operations Press the Program buttonPress the Program button to complete the program setting Programming shown below will cause Error setting Following examples will not cause Error settingProgrammed operation times of the day the indicator points CheckPress the Check button How to change programmed operation times How to clear a program of a dayTo clear a programmed holiday Explanation of the operationPower failure Additional InformationTo restart operation Ex Weekly operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG How to Use the System Controller ALL/ZONE/GRVentilation Central Ctrl ALLOnly for heat pump type Temperature range 62 ~ 80 F Only for heat pump type Temperature range 60 ~ 78 FCool or Heat or FANFollows Do not use the SET button for normal operationDisplay Description How to start group operation Stop PowerStop How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.