Sanyo RCS-SH80UA, TM-SH80UG, SHA-KC64UG, RCS-SH80UG Installation Location, Your dealer for help

Page 23

Installation Location

We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.

• Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.

Do not install the air conditioner where excessively high heat- generating objects are placed.

Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa.

Electrical Requirements

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

To warm up the system, the power mains must be turned on at least five (5) hours before operation. Leave the power mains ON unless you will not be using this appliance for an extended period.

Power mains

ON

Safety Instructions

• Read this Instruction Manual carefully before using this air

2

conditioner. If you still have any difficulties or problems, consult

your dealer for help.

The air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

Never touch the unit with wet hands.

Never use or store gasoline or other flammable vapor or liquid near the air conditioner — it is very dangerous.

This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.

Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.

Do not let children play with the air conditioner.

Do not cool or heat the room too much if babies or invalids are present.

OI-404-02 - 3EG

2 - 3

Image 23
Contents TM-SH80UG Page RCS-SH80UG Product Information ContentsAlert Symbols Electrical Requirements Installation LocationSafety Instructions Power mainsNames of Parts Remote Cotrol Unit OFF Cycle Timer Cool mode and dry mode, when the flaps are set in aTimer SET button OFF TimerOI-432-01 7EG Description Display Remote Control UnitBF C I J M Step OperationVertical vanes to the left or right Adjusting the Airflow DirectionSemi-concealed type Way type Horizontal directions manualConcealed duct type U Wall mounted type K Vertical directions automaticHeating performance Defrosting Should the power fail while the unit is runningSpecial Remarks How it worksOFF cycle TimerON Setting the TimerOperation Indication IndicationOperation Air filter How to clean the filter Care and CleaningGrille will open downward Grille Bolt screw How to remove the filterCleaning, be sure to attach the two bolt screws Air filterObstructed, the unit will not work well, and may be damaged TroubleshootingTips for Energy Saving Trouble Possible Cause RemedyPage RCS-SH80UA.WL RCS-BH80UA.WL Product or property damage This symbol refers to a hazard or unsafeInjury or death Your dealer for help Unit Display and Operation Controller for X and T Types Operation TimerSweep button SwitchAddress switch Servicing switchesFilter lamp This lamp lights when the filter needs cleaning How to Install Batteries Using the Wireless Remote ControllerRear plate Using the Wireless Remote ControllerOnly for heat pump type Transmitter Sensor DisplayTransmitter ALL Clear Setting addresses of indoor units for remote controllerDisplay Wireless Remote Controller OI-404-02 13EG Press the ON/OFF operation button again Operation without the Wireless Remote ControllerAddress switch setting OFF cycle TimerExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Programmed operation Indicator Holiday indicatorNames and Functions of Controls Turning on Operation of the programmable weekly timerHow to set the present time Proper OperationHow to set the day Setting the day Press the Program button How to set program operationsPress the Program button to complete the program setting Following examples will not cause Error setting Programming shown below will cause Error settingPress the Check button Programmed operation times of the day the indicator pointsCheck How to clear a program of a day How to change programmed operation timesExplanation of the operation To clear a programmed holidayEx Weekly operation Power failureAdditional Information To restart operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG ALL How to Use the System ControllerALL/ZONE/GR Ventilation Central CtrlHeat or FAN Only for heat pump type Temperature range 62 ~ 80 FOnly for heat pump type Temperature range 60 ~ 78 F Cool orDo not use the SET button for normal operation FollowsDisplay Description Stop How to start group operationStop Power How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.