Sanyo RCS-SH80UA, TM-SH80UG ALL Clear, Setting addresses of indoor units for remote controller

Page 31

Remote Control Unit (continued)

O: SENSOR button

Use this button to switch to the temperature sensor of the remote

 

 

 

controller.

 

 

 

 

The temperature sensor of the air-conditioner is selected at the factory

 

 

 

and the display indicates

under this selection.

 

 

 

If the remote controller is located near a heat source, such as a space

 

NOTE

 

 

 

 

heater or in direct sunlight, press the SENSOR button to switch to the

 

 

 

sensor on the indoor unit.

 

 

 

 

 

P: ACL button

Puts the wireless remote controller into pre-operation status. Always

(ALL CLEAR)

press this button after replacing the batteries.

 

 

 

 

Q: DISPLAY

Information on the operating conditions is displayed while the wireless

 

 

 

remote controller is switched on. If the unit is turned off, only the mode

 

 

 

that was set previously is still displayed.

 

 

 

 

 

NOTE

The wireless remote controller sends the temperature signal to the air conditioner regularly at three minute intervals. If the signal from the wireless remote controller stops for more than ten minutes due to the loss of the wireless remote controller or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the wireless remote controller may differ from the temperature detected at the air conditioner’s position.

How to set the ADDRESS (

)

 

 

 

Setting addresses of indoor units for remote controller

 

 

 

 

Operation

 

Indication

 

1. Press the ADDRESS button for

$

The display of the remote

more than four seconds.

controller indicates

,

 

2. By each pressing the ADDRESS

and the current address

appears and blinks.

button, the indicated address will

 

change from “ALL” to “1” through “6”

 

in turn and lap to “ALL”. Adjust the

 

address switch of an indoor unit you

 

want to operate to match its address

 

with the address indicated on the

 

remote controller.

 

NOTE

3. Press the SET button.$ The indicated address

stops blinking and remains

2

for five seconds.

 

If the set address on the remote controller matches with the controller address in an indoor unit, the buzzer will beep.

Address indication on the remote controller

Setting of the

If the remote

If the remote

If the remote

If the remote

address switch of

controller indicates

controller indicates

controller indicates

controller indicates

the controller in an

“ALL”:

“1”:

“2”:

“6”:

indoor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Match this address with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the address indicated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You can set any

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on the remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

controller.

address in the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

controller.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

To set the address to 1, 2, or 3, switch this “SWITCH” knob to the left; to set the address to 4, 5, or 6, switch this “SWITCH” knob to the right.

SWITCH

OI-404-02 - 11EG

2 - 11

Image 31
Contents TM-SH80UG Page RCS-SH80UG Alert Symbols ContentsProduct Information Electrical Requirements Installation LocationSafety Instructions Power mainsNames of Parts Remote Cotrol Unit OFF Cycle Timer Cool mode and dry mode, when the flaps are set in aTimer SET button OFF TimerOI-432-01 7EG BF C I J M Display Remote Control UnitDescription Step OperationVertical vanes to the left or right Adjusting the Airflow DirectionSemi-concealed type Way type Horizontal directions manualConcealed duct type U Wall mounted type K Vertical directions automaticHeating performance Defrosting Should the power fail while the unit is runningSpecial Remarks How it worksOFF cycle TimerON Setting the TimerOperation IndicationOperation Indication Air filter How to clean the filter Care and CleaningGrille will open downward Grille Bolt screw How to remove the filterCleaning, be sure to attach the two bolt screws Air filterObstructed, the unit will not work well, and may be damaged TroubleshootingTips for Energy Saving Trouble Possible Cause RemedyPage RCS-SH80UA.WL RCS-BH80UA.WL Injury or death This symbol refers to a hazard or unsafeProduct or property damage Your dealer for help Unit Display and Operation Controller for X and T Types Operation TimerSweep button SwitchAddress switch Servicing switchesFilter lamp This lamp lights when the filter needs cleaning How to Install Batteries Using the Wireless Remote ControllerRear plate Using the Wireless Remote ControllerOnly for heat pump type Transmitter Sensor DisplayTransmitter ALL Clear Setting addresses of indoor units for remote controllerDisplay Wireless Remote Controller OI-404-02 13EG Press the ON/OFF operation button again Operation without the Wireless Remote ControllerAddress switch setting OFF cycle TimerExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Names and Functions of Controls Indicator Holiday indicatorProgrammed operation Turning on Operation of the programmable weekly timerHow to set the present time Proper OperationHow to set the day Setting the day Press the Program button How to set program operationsPress the Program button to complete the program setting Following examples will not cause Error setting Programming shown below will cause Error settingCheck Programmed operation times of the day the indicator pointsPress the Check button How to clear a program of a day How to change programmed operation timesExplanation of the operation To clear a programmed holidayEx Weekly operation Power failureAdditional Information To restart operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG ALL How to Use the System ControllerALL/ZONE/GR Ventilation Central CtrlHeat or FAN Only for heat pump type Temperature range 62 ~ 80 FOnly for heat pump type Temperature range 60 ~ 78 F Cool orDo not use the SET button for normal operation FollowsDisplay Description Stop Power How to start group operationStop How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.