Sanyo RCS-SH80UG, TM-SH80UG, SHA-KC64UG Vent Do not move the flap with your hands, Transmitter

Page 30

2

Remote Control Unit (continued)

F: FLAP button

 

( ) 1. Use this button to set the airflow direction to a specific angle.

 

 

 

The airflow direction (

) is displayed on the remote control unit.

 

 

 

 

Operation mode

 

Number of airflow direction settings

 

 

 

 

(COOL) or

 

(DRY)

 

3

 

 

 

 

 

(HEAT) or

(FAN)

5

 

 

 

 

 

(AUTO)

 

 

3

 

 

 

 

 

Cooling mode:

 

 

 

 

 

Heating mode:

5

 

 

 

 

In the cool mode and dry mode, when the flaps are set in a

 

 

 

 

 

 

 

downward position, condensation may form and drip around

 

 

 

 

 

 

 

the vent.

 

 

 

 

 

Do not move the flap with your hands.

 

NOTE

 

 

This function is available only for models X and T.

(

)

 

 

 

 

2. Use this button to make the airflow direction sweep up and down

 

 

 

 

automatically.

 

 

 

 

 

 

Press this button several times until the (

) symbol appears on

 

 

 

 

the display.

 

 

 

 

 

 

This function is available only for models X, T and K.

.

NOTE

 

 

 

 

 

 

 

 

 

G: TIMER SET button

 

 

Use this button while the unit is operating to switch between timer

 

 

 

 

settings:

 

 

(OFF Timer)

 

:The air conditioner stops after the length of time set.

(OFF Cycle Timer)

 

:The air conditioner after the same set time every time.

(ON Timer)

 

:The air conditioner starts after the length of time set.

 

 

 

 

 

 

 

 

 

H: Time setting buttons

 

 

 

:Press this button to increase the time.

 

 

 

 

 

 

:Press this button to decrease the time.

 

 

 

 

 

 

 

 

I: SET button

 

 

Use this button to set the timer.

 

 

 

 

 

 

 

 

J: CL button

 

 

Use this button to clear the timer setting.

 

 

 

 

 

 

 

K: SENSOR

 

 

A temperature sensor inside the wireless remote controller senses the

 

 

 

 

room temperature when switched from a temperature sensor inside the

 

 

 

 

indoor unit.

 

 

 

 

 

 

 

 

L: VENTILATION button

 

 

Use this button when you installed a ventilation fan available in the

 

 

 

 

market.

 

 

 

 

 

 

Pressing this button turns on and off the fan.

 

 

 

 

 

When turning off the air conditioner, the fan will be also turned off.

 

 

 

 

While the fan is operating,

will appear in the display.

 

 

 

 

 

 

M: TRANSMITTER

 

 

When you press the buttons on the wireless remote controller, the

 

 

 

 

mark appears in the display to transmit the setting changes to the

 

 

 

 

receiver in the air conditioner.

 

 

 

 

 

 

 

 

N: ADDRESS button

 

 

By pressing the ADDRESS button of the remote controller, the display

 

 

 

 

of the remote controller indicates the current address. If this address

 

 

 

 

matches with the address of the controller in an indoor unit, the buzzer

 

 

 

 

will beep. The buzzer will always beep if the indicated address is “ALL”.

 

 

 

 

If the indicated address is “ALL”, you can operate any of your indoor

 

 

 

 

units regardless of their setting of controller addresses. Direct the

 

 

 

 

remote controller to the remote control receiver of the indoor unit you

 

 

 

 

want to operate and send a signal. (See p.11, How to set the

 

 

 

 

ADDRESS.)

 

 

2 - 10

OI-404-02 - 10EG

Image 30
Contents TM-SH80UG Page RCS-SH80UG Contents Alert SymbolsProduct Information Power mains Installation LocationSafety Instructions Electrical RequirementsNames of Parts Remote Cotrol Unit OFF Timer Cool mode and dry mode, when the flaps are set in aTimer SET button OFF Cycle TimerOI-432-01 7EG Display Remote Control Unit BF C I J MDescription Operation StepHorizontal directions manual Adjusting the Airflow DirectionSemi-concealed type Way type Vertical vanes to the left or rightWall mounted type K Vertical directions automatic Concealed duct type UHow it works Should the power fail while the unit is runningSpecial Remarks Heating performance DefrostingSetting the Timer OFF cycle TimerONIndication OperationOperation Indication Care and Cleaning Air filter How to clean the filterAir filter Grille Bolt screw How to remove the filterCleaning, be sure to attach the two bolt screws Grille will open downwardTrouble Possible Cause Remedy TroubleshootingTips for Energy Saving Obstructed, the unit will not work well, and may be damagedPage RCS-SH80UA.WL RCS-BH80UA.WL This symbol refers to a hazard or unsafe Injury or deathProduct or property damage Your dealer for help Operation Timer Unit Display and Operation Controller for X and T TypesServicing switches SwitchAddress switch Sweep buttonFilter lamp This lamp lights when the filter needs cleaning Using the Wireless Remote Controller How to Install BatteriesUsing the Wireless Remote Controller Rear plateTransmitter Sensor Display Only for heat pump typeTransmitter Setting addresses of indoor units for remote controller ALL ClearDisplay Wireless Remote Controller OI-404-02 13EG Operation without the Wireless Remote Controller Press the ON/OFF operation button againAddress switch setting Timer OFF cycleExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Indicator Holiday indicator Names and Functions of ControlsProgrammed operation Proper Operation Operation of the programmable weekly timerHow to set the present time Turning onHow to set the day Setting the day How to set program operations Press the Program buttonPress the Program button to complete the program setting Programming shown below will cause Error setting Following examples will not cause Error settingProgrammed operation times of the day the indicator points CheckPress the Check button How to change programmed operation times How to clear a program of a dayTo clear a programmed holiday Explanation of the operationTo restart operation Power failureAdditional Information Ex Weekly operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG Ventilation Central Ctrl How to Use the System ControllerALL/ZONE/GR ALLCool or Only for heat pump type Temperature range 62 ~ 80 FOnly for heat pump type Temperature range 60 ~ 78 F Heat or FANFollows Do not use the SET button for normal operationDisplay Description How to start group operation Stop PowerStop How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.