Sanyo RCS-SH80UA, TM-SH80UG, SHA-KC64UG, RCS-SH80UG instruction manual Remote Cotrol Unit

Page 7

Remote Cotrol Unit

With this remote controller, you can operate indoor units up to 8 units.

Once you set your operation conditions, you can operate the units only by pressing the ON/OFF operation button.

For the U type, the flap position is not shown on the display.

N:SENSER

J: TIMER

 

SET button

 

 

B: OPERATION lamp

K: TIME

A: ON/OFF operation

setting

button

buttons

 

G: CHECK

 

button

 

O: VENTILATION

C: MODE button

button

 

 

D: Temperature

 

setting buttons

F: FILTER reset L: SET button I: FLAP button

 

 

 

E: FAN SPEED

button

 

 

 

 

 

selector button

 

 

 

M: CL button

H: UNIT button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A: ON/OFF operation button

This button is for turning the air conditioner on and off.

 

 

 

 

 

 

 

B: Operation lamp

 

 

This lamp lights when the air conditioner is turned on.

 

 

 

 

 

 

 

C: MODE button

 

 

Use this button to select one of the following five operations:

 

(AUTO)

: Used to automatically set cooling or heating operation.

 

(HEAT)

Only for heat pump type

 

(temperature range: 62 ~ 80 °F)

 

: Used for normal heating operation.

 

(DRY)

Only for heat pump type

 

(temperature range: 60 ~ 78 °F)

 

: Used for dehumidifying without changing the room temperature.

 

(COOL)

 

 

 

(temperature range: 64 ~ 86 °F)

 

: Used for normal cooling operation.

 

(FAN)

 

 

 

(temperature range: 64 ~ 86 °F)

 

: Used to run the fan only, without heating or cooling operation.

 

 

 

 

 

 

 

D: Temperature

 

 

: Press this button to increase the temperature setting.

setting buttons

 

 

: Press this button to decrease the temperature setting.

 

 

 

 

 

 

 

 

E: FAN SPEED selector

 

 

 

 

 

 

 

button

(AUTO)

: The air conditioner automatically decides the fan speed.

 

(HI.)

: High fan speed.

 

 

 

 

(MED.)

: Medium fan speed.

 

 

 

 

(LO.)

: Low fan speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

When low fan speed is selected and the air conditioner is in cooling

 

NOTE

 

 

 

 

operation at a low outdoor temperature of less than 50°F, the air

 

 

 

 

 

 

conditioner may automatically switch to medium fan speed.

1

OI-432-01 - 5EG

1 - 5

Image 7
Contents TM-SH80UG Page RCS-SH80UG Alert Symbols ContentsProduct Information Electrical Requirements Installation LocationSafety Instructions Power mainsNames of Parts Remote Cotrol Unit OFF Cycle Timer Cool mode and dry mode, when the flaps are set in aTimer SET button OFF TimerOI-432-01 7EG BF C I J M Display Remote Control UnitDescription Step OperationVertical vanes to the left or right Adjusting the Airflow DirectionSemi-concealed type Way type Horizontal directions manualConcealed duct type U Wall mounted type K Vertical directions automaticHeating performance Defrosting Should the power fail while the unit is runningSpecial Remarks How it worksOFF cycle TimerON Setting the TimerOperation IndicationOperation Indication Air filter How to clean the filter Care and CleaningGrille will open downward Grille Bolt screw How to remove the filterCleaning, be sure to attach the two bolt screws Air filterObstructed, the unit will not work well, and may be damaged TroubleshootingTips for Energy Saving Trouble Possible Cause RemedyPage RCS-SH80UA.WL RCS-BH80UA.WL Injury or death This symbol refers to a hazard or unsafeProduct or property damage Your dealer for help Unit Display and Operation Controller for X and T Types Operation TimerSweep button SwitchAddress switch Servicing switchesFilter lamp This lamp lights when the filter needs cleaning How to Install Batteries Using the Wireless Remote ControllerRear plate Using the Wireless Remote ControllerOnly for heat pump type Transmitter Sensor DisplayTransmitter ALL Clear Setting addresses of indoor units for remote controllerDisplay Wireless Remote Controller OI-404-02 13EG Press the ON/OFF operation button again Operation without the Wireless Remote ControllerAddress switch setting OFF cycle TimerExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Names and Functions of Controls Indicator Holiday indicatorProgrammed operation Turning on Operation of the programmable weekly timerHow to set the present time Proper OperationHow to set the day Setting the day Press the Program button How to set program operationsPress the Program button to complete the program setting Following examples will not cause Error setting Programming shown below will cause Error settingCheck Programmed operation times of the day the indicator pointsPress the Check button How to clear a program of a day How to change programmed operation timesExplanation of the operation To clear a programmed holidayEx Weekly operation Power failureAdditional Information To restart operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG ALL How to Use the System ControllerALL/ZONE/GR Ventilation Central CtrlHeat or FAN Only for heat pump type Temperature range 62 ~ 80 FOnly for heat pump type Temperature range 60 ~ 78 F Cool orDo not use the SET button for normal operation FollowsDisplay Description Stop Power How to start group operationStop How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.