Sanyo SHA-KC64UG, TM-SH80UG, RCS-SH80UG Transmitter Sensor Display, Only for heat pump type

Page 29

Remote Cotrol Unit

A:ON/OFF operation button

B:MODE button

D:FAN SPEED selector button

G:TIMER SET button

H:Time setting buttons

I:SET button

J:CL button

E:FILTER reset button

P:ACL button

M:TRANSMITTER

K:SENSOR

Q: DISPLAY

C:Temperature setting buttons

F: FLAP button

N: ADDRESS button

L:VENTILATION button

O: SENSOR button

A: ON/OFF operation button

This button is for turning the air conditioner on and off.

 

 

 

 

B: MODE button

 

 

Use this button to select one of the following five operations:

 

(AUTO)

: Used to automatically set cooling or heating operation.

 

(HEAT)

Only for heat pump type

(temperature range: 62 ~ 80 °F)

 

: Used for normal heating operation.

 

(DRY)

Only for heat pump type

(temperature range: 60 ~ 78 °F)

 

: Used for dehumidifying without changing the room temperature.

 

(COOL)

 

(temperature range: 64 ~ 86 °F)

 

: Used for normal cooling operation.

 

(FAN)

 

(temperature range: 64 ~ 86 °F)

 

: Used to run the fan only, without heating or cooling operation.

 

 

 

 

C: Temperature

 

 

: Press this button to increase the temperature setting.

setting buttons

 

 

: Press this button to decrease the temperature setting.

 

 

 

 

 

D: FAN SPEED selector

 

 

 

 

button

(AUTO)

: The air conditioner automatically decides the fan speed.

 

(HI.)

: High fan speed.

 

 

(MED.)

: Medium fan speed.

 

 

(LO.)

: Low fan speed.

 

 

 

 

 

 

E: FILTER reset button

 

 

Use this button to reset the filter sign

. The air conditioner has a

 

 

 

timer for the filter and informs you when the filter needs cleaning.

 

 

 

 

 

 

 

When low fan speed is selected and the air conditioner is in cooling

 

NOTE

 

 

 

 

operation at a low outdoor temperature of less than 50°F, the air

 

 

 

 

 

 

conditioner may automatically switch to medium fan speed.

2

OI-404-02 - 9EG

2 - 9

Image 29
Contents TM-SH80UG Page RCS-SH80UG Product Information ContentsAlert Symbols Safety Instructions Installation LocationPower mains Electrical RequirementsNames of Parts Remote Cotrol Unit Timer SET button Cool mode and dry mode, when the flaps are set in aOFF Timer OFF Cycle TimerOI-432-01 7EG Description Display Remote Control UnitBF C I J M Step OperationSemi-concealed type Way type Adjusting the Airflow DirectionHorizontal directions manual Vertical vanes to the left or rightConcealed duct type U Wall mounted type K Vertical directions automaticSpecial Remarks Should the power fail while the unit is runningHow it works Heating performance DefrostingOFF cycle TimerON Setting the TimerOperation Indication IndicationOperation Air filter How to clean the filter Care and CleaningCleaning, be sure to attach the two bolt screws Grille Bolt screw How to remove the filterAir filter Grille will open downwardTips for Energy Saving TroubleshootingTrouble Possible Cause Remedy Obstructed, the unit will not work well, and may be damagedPage RCS-SH80UA.WL RCS-BH80UA.WL Product or property damage This symbol refers to a hazard or unsafeInjury or death Your dealer for help Unit Display and Operation Controller for X and T Types Operation TimerAddress switch SwitchServicing switches Sweep buttonFilter lamp This lamp lights when the filter needs cleaning How to Install Batteries Using the Wireless Remote ControllerRear plate Using the Wireless Remote ControllerOnly for heat pump type Transmitter Sensor DisplayTransmitter ALL Clear Setting addresses of indoor units for remote controllerDisplay Wireless Remote Controller OI-404-02 13EG Press the ON/OFF operation button again Operation without the Wireless Remote ControllerAddress switch setting OFF cycle TimerExample To start the air conditioner after 10.5 hours OI-404-02 18EG TM-SH80UG OI-432-03 2EG OI-432-03 3EG Features Programmed operation Indicator Holiday indicatorNames and Functions of Controls How to set the present time Operation of the programmable weekly timerProper Operation Turning onHow to set the day Setting the day Press the Program button How to set program operationsPress the Program button to complete the program setting Following examples will not cause Error setting Programming shown below will cause Error settingPress the Check button Programmed operation times of the day the indicator pointsCheck How to clear a program of a day How to change programmed operation timesExplanation of the operation To clear a programmed holidayAdditional Information Power failureTo restart operation Ex Weekly operationSHA-KC64UG Functions of buttons Display OI-432-04 3EG ALL/ZONE/GR How to Use the System ControllerVentilation Central Ctrl ALLOnly for heat pump type Temperature range 60 ~ 78 F Only for heat pump type Temperature range 62 ~ 80 FCool or Heat or FANDo not use the SET button for normal operation FollowsDisplay Description Stop How to start group operationStop Power How to start collective operation Page Page Sanyo Fisher Company

RCS-SH80UA, RCS-SH80UG, SHA-KC64UG, TM-SH80UG specifications

Sanyo has long been recognized for its innovative contributions to consumer electronics, particularly in the realm of air conditioning and climate control systems. Among its diverse product offerings, the Sanyo RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models stand out for their superior technology and user-friendly features, making them ideal choices for both residential and commercial environments.

The Sanyo RCS-SH80UA is an advanced split system air conditioner designed to provide efficient cooling and heating solutions. One of its main features is its inverter technology, which allows the unit to automatically adjust its compressor speed to suit the temperature needs of the space, resulting in energy savings and quieter operation. The RCS-SH80UA also boasts a sleek and compact design, making it easy to install in various settings while enhancing the room's aesthetic appeal. In addition, it includes a multi-stage air filtration system that effectively removes dust, allergens, and other airborne impurities, ensuring a healthier indoor environment.

The SHA-KC64UG model emphasizes versatility and ease of use. It is equipped with a powerful remote control that enables users to conveniently switch between cooling, heating, and fan modes. This model also features a programmable timer, allowing users to set specific operation schedules, further optimizing energy consumption. Its high cooling and heating capacity make it suitable for larger spaces, while its whisper-quiet operation is designed to provide comfort without intrusive noise.

The TM-SH80UG and RCS-SH80UG models share several characteristics that appeal to environmentally-conscious consumers. Both units utilize advanced refrigerant technology that reduces environmental impact without sacrificing cooling efficiency. They are built with energy-efficient components that comply with modern sustainability standards, offering an eco-friendly alternative for climate control. Additionally, the TM-SH80UG includes smart technology allowing for connectivity to smart home systems, enabling remote operation via smartphone applications.

Overall, Sanyo’s RCS-SH80UA, SHA-KC64UG, TM-SH80UG, and RCS-SH80UG models exemplify the company’s commitment to innovation and customer satisfaction. With their advanced technology, energy efficiency, and user-friendly operations, these air conditioning systems are well-suited to meet the demands of today's modern living and working environments.