Grizzly G0574 installation instructions 220VOLT

Page 27

110 VOLT

MOTOR WIRES

BLACK

YELLOW

WHITE

RED

NOTE: THE WIRES FROM THE

POWER SUPPLY, EXCEPT THE

GREEN GROUND WIRE, ARE

INTERCHANGABLE, THEREFORE

COLORS ARE NOT SPECIFIED.

220VOLT

GREEN (GROUND) TO 110 VOLT POWER SUPPLY

MOTOR WIRES

BLACK

YELLOW

RED

WHITE

GREEN (GROUND) TO 220 VOLT POWER SUPPLY

G1140 Edge Sander

-23-

Image 27
Contents Manual Insert Radiusing SanderEdge Sander Page Table Of Contents Safety Instructions For Power Tools SafetyLength AMP Rating Additional Safety Instructions For Sanders Grounding Circuit Requirements220V/110V Operation Circuit LoadExtension Cords Wiring Diagram Commentary General InformationPiece Inventory UnpackingClean Up Site Considerations Beginning Assembly Feet AssemblyWorking Table Horizontal / vertical brace installed G1140 Edge SanderSee Figure Attaching the miter body Miter Body Quick Release LeverDust hood mounted in place Auxiliary Table Dust HoodBack stop properly installed Back Stop Belt InstallationBelt Tracking Auxiliary Table AdjustmentsTable Tilt Table Height Table height adjustment G1140 Edge SanderPlaten lock bolt Platen Tilt Belt TensionTest Run Edge & End Sanding OperationsTypical face sanding method Horizontal Sanding Contour SandingMaintenance GeneralTableLubrication Closure Machine Data 220VOLT 44A 49A 46A Description Warranty and Returns Warranty Card Grizzly INDUSTRIAL, INC