Sanyo operation manual Field wiring DE, Start, Stop

Page 19

ENVIRONMENTALLY FRIENDLY TECHNOLOGY

Field wiring (DE)

SUPER ABSORPTION

Figure 26. Typical electrical field connection diagram - Direct-fired (DE)

To power source

 

 

 

 

 

 

 

 

 

3 Ph,50/60Hz

 

(52CO)

 

(52CH)

 

(52F)

 

 

400V, 415V, 440V

 

 

 

 

 

 

 

 

 

 

 

 

 

For emergency stop signal

 

 

 

 

 

 

 

 

 

(Those terminals are

Coolingwater interlockpump

 

Chilled/hotwater interlockpump

 

Ventilationfan interlock

 

For message signal

those terminals

 

 

 

connected by jumper)

 

 

 

 

 

 

 

 

 

Remove the jumper

 

 

 

 

 

 

 

 

 

before using

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start/Stop sequence of auxiliary equipments

Start

 

 

 

Chilled/hot water pump

 

 

 

 

Start signal

 

operates and

 

 

 

ventilation fan operates

 

 

 

 

Stop

 

 

 

Stop signal

 

Diluted operation starts

 

 

 

Cooling water pump operates and then cooling tower fan operates

Cooling water pump stops and cooling tower fan stops

Machine operates

Chilled/hot water pump stops and ventilation fan stops

Operate air conditioners

Chiller stops entirely

Stop air conditioners

E

R0

S0

T0

1

2

3

4

10

135

136

138

171

84

85

Remote signal

The unit can be operated by the following five type signal.

(1)Non-voltage normal open contact(A) for start & stop (DC24V 10mA). :Wiring the terminal 330 and 333.

(2)Non-voltage normal open contact(A) for start (DC24V 10mA). :Wiring the terminal 330 and 333.

Non-voltage normal open contact(A) for stop (DC24V 10mA). :Wiring the terminal 331 and 333.

(3)Non-voltage normal open contact(A) for start (DC24V 10mA).

Terminal strips in the control panel

300

301

302

303

304

305

306

307

308

309

 

 

 

 

 

 

 

 

314

315

316

317

 

 

 

 

 

 

 

 

 

320

321

322

323

324

325

326

327

 

 

 

 

 

 

 

 

334

335

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52

 

 

 

CO

voltageMax.and currentMax. 250V,0.1A:AC

 

 

23

 

 

CO

 

 

 

 

51

51

51

 

CH

CO

CT

:Wiring the terminal 330 and 333.

Non-voltage normal close contact(B) for stop (DC24V 10mA). :Wiring the terminal 331 and 333.

(4)Continuous signal of DC/AC 24V for start & stop.

:Wiring the terminal 330 and 332.(Those terminals are non-polarity.) (5)Pulse signal of DC/AC 24V for start.

:Wiring the terminal 330 and 332.(Those terminals are non-polarity.) Signal of DC/AC 24V for stop.

:Wiring the terminal 331 and 332.(Those terminals are non-polarity.)

Terminal strips in the control panel

171

171

171

 

 

COM

L

52

52

52

L

CH

CO

F

Answer back indication

Chilled/hot water pump

Cooling water pump

Ventilation fan

Remote signal indication

Symbols

L :Indication lamp

51CH:Chilled/hot water pump overcurrent relay 51CO:Cooling water pump overcurrent relay

52

CT L

Cooling tower fan

Cooling mode indication

LL L LL

Heating mode indication

Alarm indication

Operation indication Stop indication

Buzzer signal indication

51CT :Cooling tower fan overcurrent relay 23CO:Cooling tower fan thermostat

L

Combustion indication

330

333

332

330

331

333

332

330

331

333

332

330

332

330

331

332

 

A

 

 

A

A

 

A

 

B

 

 

 

 

 

 

4Y

 

 

4Y

4Y

 

 

4Y

 

4Y

 

 

 

 

 

 

1

 

 

1

2

 

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC/AC 24V

DC/AC 24V

 

 

(1)

 

 

 

(2)

 

 

 

(3)

 

 

(4)

 

(5)

 

Note

1.Be sure to insert 23CO at the cooling water inlet side.

2.Be sure to wire the 52CH(interlock) between terminals 171 and 136. 3.Be sure to wire the 52CO(interlock) between terminals 171 and 135. 4.Be sure to wire the 52F(interlock) between terminals 171 and 138.

5.Be sure to wire the chilled/hot water pump control relay between terminals 302 and 303. 6.Be sure to wire the cooling water pump control relay between terminals 304 and 305. 7.Be sure to wire the ventilation fan between terminals 306 and 307.

34

35

Image 19
Contents Making the World a More Comfortable Place Contents Many applications Electrical peak power shavingHeating and cooling operation Double effect absorption cycleGraph 2. Tendency of absorbent concentration Expert function by self-diagnosisExhaust gas temp 236 C CH W temp 12.3 7.1 C Sanyo control systemDisplay and control board Generator temp 149 CSteam valve opening control Speedy digital PID controlSaving energy with the inverter Purge systemCrystallization protection High temperature generator safety controlExpansion of safety operating zone Double effect typeLower shell Absorption cooling cycleUpper shell Schematic cooling cycleCooling Water outlet Low Temperature GeneratorCooling cycle Heating cycleDouble effect direct-fired absorption chiller / heaters Scope of order DE Scope of supply DECOW Hole33ø DE-31ThruDE-32 ABC DEF Detail of weld . Washers are supplied with the chiller Foundation dimensional data DEControl panel DE To mount the chillerStart Field wiring DEStop Ignition gas Stop signal Chiller stop36 sec IgnitionTypical steel stack Flue flange dimensional dataField supply Steel material Dimensional data Flue & stack connectionGas train Burner descriptionCooling cycle schematic Typical piping diagram DEGeneral remarks on piping work Double effect steam-fired absorption chillers Scope of order NE Scope of supply NE877 341 329 2311 1896 1003 364 2089 Eitherside CHWin 3289 3104 3400 1078 396 Out 1515 410 684 COWin R700 2930 1971 33hole Wireconnectionø Out Connectionø41 Wire Out 140 Control panel NE Foundation dimensional data NETypical electrical field connection diagram Steam-fired NE Field wiring NEGeneral remarks on piping-laying work Typical piping diagram-laying NEHot water-fired absorption chillers Scope of order LE Scope of supply LEMain unit Rust preventive paint Control panel Finish paint BCD 2255 835 926 Side Spaceeither COWinlet Tuberemoval COWoutlet 976 Side 3886 4500 Removalspaceeither Tube LEThru52-LE 57.Figure Customer.theControl panel LE Foundation dimensional data LEGenerator temp 69 C For emergency stop signal Field wiring LEWork outside the area surrounded by this line Typical piping diagram-laying LECapacity ratings LE Capacity ratings DE and NEFlowrate Dropcurve Pressure WaterCooling pressure drop LEcurve Leveling requirements Location and space requirementsWater piping Field piping instructionInsulation data Insulation DE Insulation NERupture disk mounting Insulation LEWater treatment Quality control of cooling waterCooling water blow system

DE specifications

Sanyo DE is an innovative line of home appliances and electronics that showcases Sanyo's commitment to quality, efficiency, and user-centered design. This series includes various products, such as air conditioners, refrigerators, and microwaves, all engineered to enhance the everyday living experience.

One of the standout features of Sanyo DE appliances is their energy efficiency. Many models are equipped with advanced technologies that adhere to stringent energy-saving standards, helping consumers reduce their electricity bills while minimizing their environmental footprint. The use of inverter technology in air conditioners, for instance, allows for precise temperature control and significant reductions in energy consumption.

Sanyo DE also emphasizes smart technology integration. Many products come with Wi-Fi capabilities, enabling users to control their appliances remotely via mobile apps. This connectivity makes it easier to monitor energy usage, adjust settings, and receive alerts about maintenance needs. Users can enjoy added convenience as they can pre-heat their ovens or set their air conditioners to the desired temperature before arriving home.

Another key characteristic of Sanyo DE is its focus on durability and reliability. Each product is built with high-quality materials and undergoes rigorous testing to ensure long-lasting performance. The robust construction not only enhances the lifespan of the appliances but also provides peace of mind to users concerning their safety and functionality.

In terms of design, Sanyo DE products are crafted to blend seamlessly into modern homes with sleek and contemporary aesthetics. The intuitive user interfaces are designed for ease of use, featuring clear displays and simple controls, allowing users of all ages to operate the appliances without any hassle.

Furthermore, Sanyo DE pays attention to noise reduction. Many appliances incorporate sound dampening technologies, making them ideal for use in residential settings, where quiet operation is critical. Whether it’s a refrigerator running seamlessly in the background or an air conditioner cooling the room without disruption, Sanyo DE ensures a pleasant home atmosphere.

Overall, Sanyo DE exemplifies a fusion of advanced technology, energy efficiency, and user-friendly design. With a diverse range of appliances, Sanyo DE is committed to enhancing the lives of its users through thoughtful innovation and reliable performance.