Ingersoll-Rand X41 technical manual UP6RE 7.5-15 175, UP6RX 7.5-15 175 2of3

Page 79

UP6RE 7.5–15 175, UP6RX 7.5–15 175

UP6RE 7.5–15 175, UP6RX 7.5–15 175 2of3 Page 79

Image 79
Contents More Than Air. Answers Table of Contents Intellisys S3 1of2 Intellisys S3 2of2 Introduction X4I System Automation Installation Power Supply Pressure Sensor Connection Input Functions Alarm Run Ready Alarm LampOutput Functions C02 X06 28 RS485X4I Overview Specifications16 is a representation for After the conversion is completed Unigy Phase 1 1of2 Unigy PhaseUnigy Phase 1 2of2 Unigy Phase 2/3 1of2 Unigy Phase 2/3Unigy Phase 2/3 2of2 Nirvana 15 30KW 20-40HP 1of2 Nirvana 15 30KW 20 40HPNirvana 15 30KW 20-40HP 2of2 Nirvana 15 30KW 20-40HPPage SSR Redeye 1of3 SSR RedeyeSSR Redeye FV 2of3 SSR Redeye FVSSR Redeye SD 3of3 SSR Redeye SDPage 0VAC 1M 110VAC SE UP 1of2Intellisys SE UP Series SE UP 2of2 Intellisys SE ESA Series SE ESA 1of2SE ESA 2of2 J5 34 33 SE DSA 1of2Intellisys SE DSA Contact Cooled SE DSA 2of2 Page Intellisys SG SG SSR 1of21Sb P2 3 2SG SSR 2of2 SG Sierra 1of2 SG SierraSG Sierra 2of2 Page SSR UP5 11-22 SD 1of2 SSR UP5 11-22 SDSSR UP5 11-22 SD 2of2 Contact 110VAC SSR UP5 22-37 SDSSR UP5 22-37 SD 1of2 Relay ContactSSR UP5 22-37 SD 2of2 Contact To TR Relay To M Contact SSR UP6 15-30 FVSSR UP6 15-30 FV 1of2 Restart TD RelaySSR UP6 15-30 FV 2of2 SSR UP6 15-30 SD 1of2 SSR UP6 15-30 SDContact To TR Relay To 1M Contact To 2M Contact VAC SSR UP6 15-30 SD 2of2 To TR Relay To 1M Contact SSR UP6 40-50 FVSSR UP6 40-50 FV 1of2 Relay Relay Contact ContactSSR UP6 40-50 FV 2of2 Load/Unload To 1M Contact C01 VFD/fixed Load Enable To TR RelaySSR UP6 40-50 SD SSR UP6 40-50 SD 1of2SSR UP6 40-50 SD 2of2 To HM UP6 5-15 FV 1PH 60HzUP6 5-15 FV 1PH 60Hz 1of2 To CR RelayUP6 5-15 FV 1PH 60Hz 2of2 UP6 5-15 FV 3PH 60Hz 1of2 UP6 5-15 FV 3PH 60HzUP6 5-15 FV 3PH 60Hz 2of2 UP6 5-15 SD 3PH 60Hz 1of2 UP6 5-15 SD 3PH 60Hz110VAC To EDV To 1M/1S/2M Contacts To TD Relay VAC 1M UP6 5-15 SD 3PH 60Hz 2of2 UP6 5-15 FV 3PH 50Hz 1of2 UP6 5-15 FV 3PH 50HzTo HM 110VAC HATSTo EDV KM1/KM2/KM3 Contacts To KM1 UP6 5-15 FV 3PH 50Hz 2of2 UP6 5-15 SD 3PH 50Hz 1of2 UP6 5-15 SD 3PH 50HzUP6 5-15 SD 3PH 50Hz 2of2 SSR M15-22c 20-30HP XF EP HP HXP 50-60Hz 1of2 SSR M15-22c 20-30HP XF EP HP HXP 50-60HzSSR M15-22c 20-30HP XF EP HP HXP 50-60Hz 2of2 M37-50 1of2 M37-50M37-50 2of2 EP 20-30 ESP FV 1of2 EP 20-30 ESP FVEP 20-30 ESP FV 2of2 EP 20-30 ESP SD 1of2 EP 20-30 ESP SDContact To 1TD Relay To 2M Contact VAC EP 20-30 ESP SD 2of2 Page Nirvana SGN/SGNe 1of3 Nirvana SGN/SGNeNirvana SGN/SGNe 2of3 Nirvana SGN/SGNe 3of3 SI1 Interface to Redeye, SE, SG Controllers SI1 Interface to Redeye, SE, SG ControllersRedeye X4I Interconnect To Ingersoll Rand Intellisys S3 X4I Interconnect To Ingersoll Rand Intellisys S3X02 Intellisys S3Intellisys S3 1of2 X04Intellisys S3 2of2 Page UP6RE 7.5-15 175, UP6RX 7.5-15 175 1of3 UP6RE 7.5-15 175, UP6RX 7.5-15110VAC To ETM UP6RE 7.5-15 175, UP6RX 7.5-15 175 2of3 UP6RE 7.5-15 175, UP6RX 7.5-15 175 3of3 External 110VAC Contact L2 Models 2340, 2475, 2545, 7100, 15TModels 2340, 2475, 2545, 7100, 15T & 3000 10f3 To Customer Supplied External NeutralModels 2340, 2475, 2545, 7100, 15T & 3000 2of3 Models 2340, 2475, 2545, 7100, 15T & 3000 3of3 X4I Compressor #1 X01 Terminal Pressure