PS7060 MULTIQUIP SAW — RULES FOR SAFE OPERATION

Always store equipment properly when not being used. Equipment should be stored in a clean, dry location out of the reach of children. When storing the saw in freezing weather, blow out the water lines to prevent damage to components in the water delivery system.

Diamond Blade Safety

Use appropriate steel-centered diamond blades manufactured for particular use on your saw. See further blade information in this manual.

DON'T POLLUTE! Waste Oils and other chemicals must be disposed of in a manner consistent with local and state environmental protection regulations.

Always observe all applicable compulsory regulations relevant to environmental protection, especially fuel storage, the handling of hazardous substances, and the wearing of protective clothing and equipment. Instruct the user as necessary, or, as the user, request this information and training.

WARNING

ALWAYS inspect diamond blades before each use. The blade should exhibit no cracks, dings, or flaws in the steel centered core and/or rim. Center (arbor) hole must be undamaged and true.

Examine blade flanges for damage and excessive wear.

Ensure the cleanliness of the blade before blade is installed. Blade should fit snugly on the shaft and against the inside/ outside blade flanges.

Ensure the blade is marked with an operating speed greater than the spindle speed of the saw.

Only cut the material that is specified for the diamond blade. Read the specifications of the diamond blade to ensure the proper tool has been matched to the material being cut.The saw has been engineered for WET CUTTING. Ensure a WET CUTTING blade is being used and that the water supply system to the blade is properly functioning and being used.

ALWAYS keep blade guards in place. Exposure of the diamond blade must not exceed 180 degrees.

Ensure that the diamond blade does not come into contact with the ground or surface during transportation. DO NOT drop the diamond blade on ground or surface.

The engine governor is set to permit maximum engine speed in a no-load condition. Do not tamper with the engine governor to increase the speed. Increasing the engine speed could allow the maximum rated spindle speed to be exceeded, creating an unsafe condition.

Ensure that the blade is mounted for proper operating direction.

Adhere to the Blade Manufacturer's recommendations on handling, storage, and safe usage of blades.

PAGE 14 — PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08)

Image 14
Contents Models Proposition 65WARNING SILICOSIS/RESPIRATORYWARNINGS PS7060 Multiquip SAW Table of Contents PS7060 Multiquip SAW Dimensions PS7060 Multiquip SAW Specifications BF3L2011 Uncrated WeightCrated Weight Transmission PumpTraining Checklist Training ChecklistDaily PRE-OPERATION Checklist Daily PRE-OPERATION ChecklistSafety Message Alert Symbols Always wear approved eye and hearing protection Safety Message Alert SymbolsAlways wear approved respiratory protection PS7060 Multiquip SAW Rules for Safe Operation SafetyDo not operate or service this Rules for Safe OperationPS7060 Multiquip SAW Rules for Safe Operation Always keep the work area well organizedDiamond Blade Safety Never transport the saw with the blade mounted Saw Lifting and Loading SafetyTransporting Via truck/trailer Maintenance Safety BatteryCase the battery liquid dilute EmergenciesEngine FeaturesIntended Use Water SystemPage PS7060 Multiquip SAW Serial TAG Information Auxiliary Switch PS7060 Multiquip SAW Controls and IndicatorsSocket Connector Use to plug in optional light LeftWater FlowValve Meters water supplyPS7060 Multiquip SAW Components Blade Wrench Light AssemblyRear Access Panel Oil in crankcase PS7060 Multiquip SAW Basic Engine InformationAccelerator system Oil Fill Cap Remove to add engine oilRatio PS7060 Multiquip SAW Choosing Proper Blade SizeChoosing Proper Blade Size Engine RPM / 2000 desired BS RPM =Optimum Blade RPM Range Blade RPM vs. Surface Feet Per Minute SfpmSpecifictoolsto be Used Align flange pin through the blade into the inner flange PS7060 Multiquip SAW Installing the BladeInstalling the Blade Blade Direction of Rotation Tightening Direction Right SideRemove existing blade. See previous section PS7060 Multiquip SAW Installing the Blade12 In .48 cm Lbs 56.7-79.4 Kg Blade Guard OrderConnect the water delivery hose to the Blade Guard. Figure PS7060 Multiquip SAW Blade GuardsBlade Guards with Standard Water Systems Installing the Flange Guard PS7060 Multiquip SAW Water Delivery SystemsPS7060 Multiquip SAW SLH and Battery Stay-Level Handlebars SLHHandle fuel safely PS7060 Multiquip SAW Fueling the SAWFueling the Saw Do not smoke while refuelingCold Weather Operation PS7060 Multiquip SAW Pointer AdjustmentPointer Adjustment Draining theWater SystemTop View Raise Lower Controls Setting the Depth IndicatorPS7060 Multiquip SAW RAISE-LOWER Controls PS7060 Multiquip SAW Bladeshaft Engage System Starting and Stoppingthe Engine PS7060 Multiquip SAW OperationWheel Drive System Operating Synopsis PS7060 Multiquip SAW OperationRestarting After Running Out of Fuel PS7060 Multiquip SAW Loading and Transporting Avoid InjuryPS7060 Multiquip SAW Maintenance MaintenancePS7060 Multiquip SAW Maintenance Air Cleaner ComponentsEngine Oil Filter Filter Seal Changing Engine Oil And FilterOil Filter 125 Hours Lubrication Fuel Filter 500 HoursEngine Tune-Up Prevent Crush InjuryRemove the Air Box Cover, Item D Battery/Charging SystemCooling System Refer to your engine manual for additional informationRemove lower battery retainer, Item B, Figure Replacing the BatteryRemove rear access panel Replace guards and panels prior to starting the engineBlade Shaft Drive Belt Pump Drive Belt BeltTensioner Pulley Belts and PulleysTo Stop Bladeshaft Rotation To Start Bladeshaft Rotation16 Nut Tensioner Nut Adjustment Notches Rotary BeltTensionerBlade Alignment Drive System AlignmentBlade Flange Puller Removing the Inner Blade Flange Installing the Inner Blade Flange Blade Shaft Tolerance Inner Flange Inside FaceCircuit Breakers and Starter Relays Circuit Breakers Relay, Glow Plug DelayTimer Starter RelayMaximum Cut Depth Adjustment PTO Drive Maintenance Raise-Lower SystemRaise-Lower System Troubleshooting Push-Pull Cable Neutral Safety Switch R Control Adjustment Hydraulic System MaintenanceAdjustment Nut Rod End Hydraulic Oil SystemHydraulic System Decommissioning Saw/Components Remove the oil reservoir cap to speed oil drainingLong Term Storage Symptom Possible Cause Solution PS7060 Multiquip SAW Troubleshooting PS7060 Multiquip SAW Troubleshooting Blade TroubleshootingPage PS7060 Multiquip SAW Electrical Diagramto SN AF3700155 PS7060 Multiquip SAW Electrical Diagram SN AF3700156 & UP Reservoir Lift Cylinder AssemblyLift Pump PS7060 Multiquip SAW Hydraulic Schematic SN AF3700156 & UP Terms and Conditions of Sale Parts Freight PolicyPage Canada Brazil United StatesMexico United Kingdom Your Local Dealer is
Related manuals
Manual 82 pages 54.16 Kb

PS706020, PS706036, PS706026 PS706030, PS706016 specifications

The Multiquip PS706026, PS706030, PS706036, and PS706020 are highly regarded in the world of portable generators, designed to offer optimum performance and reliability for various applications. These models showcase a blend of advanced technologies and user-friendly features, catering to both professional and residential needs.

One of the standout features of the Multiquip PS706 series is their robust and efficient engines, which deliver reliable power output. These generators are equipped with a powerful Honda engine, ensuring superior performance even in demanding conditions. The engines are designed to be fuel-efficient, allowing users to save on fuel costs while maximizing operational time.

Another significant aspect of the PS706 series is their electric start capability. This feature offers added convenience, enabling users to start the generator at the push of a button. Additionally, the generators are equipped with a recoil backup starter, ensuring that users have a reliable starting method in the event of an electrical failure.

The generators are built with a heavy-duty frame and are designed to withstand tough job site conditions. Their compact and portable design allows for easy transportation, making them an excellent choice for contractors, construction sites, and recreational use. The inclusion of rugged wheels and a comfortable handle ensures that moving the generator is hassle-free.

Moreover, the PS706 series showcases impressive noise-reduction technology. With a well-designed muffler system, these generators operate quietly, making them suitable for use in residential areas and during outdoor events where noise restrictions may apply.

Safety features are also paramount in the Multiquip PS706 series. They are equipped with circuit breakers to prevent overload and automatic low-oil shutdown to protect the engine from damage. This focus on safety ensures that users can operate the generators with peace of mind.

The PS706 series generators have multiple outlet options, providing versatility in power supply. Users can charge multiple devices simultaneously, thanks to the inclusion of 120V/240V receptacles and GFCI-protected outlets.

In summary, the Multiquip PS706026, PS706030, PS706036, and PS706020 generators are engineered with high-performance engines, easy starting options, and advanced safety features. Their durability, portability, and noise-reduction capabilities make them suitable for a wide range of applications, from construction to home backup power. With these models, users can expect reliable and efficient performance even in the most demanding environments.