Multiquip PS706016, PS706026 PS706030, PS706020, PS706036 Silicosis/Respiratorywarnings

Page 3

SILICOSIS/RESPIRATORYWARNINGS

WARNING

SILICOSIS WARNING

Grinding/cutting/drilling of masonry, concrete, metal and other materials with silica in their composition may give off dust or mists containing crystalline silica. Silica is a basic component of sand, quartz, brick clay, granite and numerous other minerals and rocks. Repeated and/or substantial inhalation of airborne crystalline silica can cause serious or fatal respiratory diseases, including silicosis. In addition, California and some other authorities have listed respirable crystalline silica as a substance known to cause cancer. When cutting such materials, always follow the respiratory precautions mentioned above.

WARNING

RESPIRATORY HAZARDS

Grinding/cutting/drilling of masonry, concrete, metal and other materials can generate dust, mists and fumes containing chemicals known to cause serious or fatal injury or illness, such as respiratory disease, cancer, birth defects or other reproductive harm. If you are unfamiliar with the risks associated with the particular process and/or material being cut or the composition of the tool being used, review the material safety data sheet and/or consult your employer, the material manufacturer/supplier, governmental agencies such as OSHA and NIOSH and other sources on hazardous materials. California and some other authorities, for instance, have published lists of substances known to cause cancer, reproductive toxicity, or other harmful effects.

Control dust, mist and fumes at the source where possible. In this regard use good work practices and follow the recommendations of the manufacturers or suppliers, OSHA/NIOSH, and occupational and trade associations. Water should be used for dust suppression when wet cutting is feasible. When the hazards from inhalation of dust, mists and fumes cannot be eliminated, the operator and any bystanders should always wear a respirator approved by NIOSH/MSHA for the materials being used.

Image 3
Contents Models Proposition 65WARNING SILICOSIS/RESPIRATORYWARNINGS PS7060 Multiquip SAW Table of Contents PS7060 Multiquip SAW Dimensions PS7060 Multiquip SAW Specifications Transmission Pump Uncrated WeightCrated Weight BF3L2011Training Checklist Training ChecklistDaily PRE-OPERATION Checklist Daily PRE-OPERATION ChecklistSafety Message Alert Symbols Safety Message Alert Symbols Always wear approved respiratory protectionAlways wear approved eye and hearing protection Rules for Safe Operation SafetyDo not operate or service this PS7060 Multiquip SAW Rules for Safe OperationAlways keep the work area well organized PS7060 Multiquip SAW Rules for Safe OperationDiamond Blade Safety Saw Lifting and Loading Safety Transporting Via truck/trailerNever transport the saw with the blade mounted Emergencies BatteryCase the battery liquid dilute Maintenance SafetyWater System FeaturesIntended Use EnginePage PS7060 Multiquip SAW Serial TAG Information LeftWater FlowValve Meters water supply PS7060 Multiquip SAW Controls and IndicatorsSocket Connector Use to plug in optional light Auxiliary SwitchBlade Wrench Light Assembly Rear Access PanelPS7060 Multiquip SAW Components Oil Fill Cap Remove to add engine oil PS7060 Multiquip SAW Basic Engine InformationAccelerator system Oil in crankcaseEngine RPM / 2000 desired BS RPM = PS7060 Multiquip SAW Choosing Proper Blade SizeChoosing Proper Blade Size RatioBlade RPM vs. Surface Feet Per Minute Sfpm Optimum Blade RPM RangeSpecifictoolsto be Used Blade Direction of Rotation Tightening Direction Right Side PS7060 Multiquip SAW Installing the BladeInstalling the Blade Align flange pin through the blade into the inner flangePS7060 Multiquip SAW Installing the Blade 12 In .48 cm Lbs 56.7-79.4 KgRemove existing blade. See previous section Order Blade GuardPS7060 Multiquip SAW Blade Guards Blade Guards with Standard Water SystemsConnect the water delivery hose to the Blade Guard. Figure PS7060 Multiquip SAW Water Delivery Systems Installing the Flange GuardStay-Level Handlebars SLH PS7060 Multiquip SAW SLH and BatteryDo not smoke while refueling PS7060 Multiquip SAW Fueling the SAWFueling the Saw Handle fuel safelyDraining theWater System PS7060 Multiquip SAW Pointer AdjustmentPointer Adjustment Cold Weather OperationSetting the Depth Indicator PS7060 Multiquip SAW RAISE-LOWER ControlsTop View Raise Lower Controls PS7060 Multiquip SAW Bladeshaft Engage System PS7060 Multiquip SAW Operation Wheel Drive SystemStarting and Stoppingthe Engine PS7060 Multiquip SAW Operation Restarting After Running Out of FuelOperating Synopsis Avoid Injury PS7060 Multiquip SAW Loading and TransportingMaintenance PS7060 Multiquip SAW MaintenanceAir Cleaner Components PS7060 Multiquip SAW MaintenanceChanging Engine Oil And Filter Oil Filter 125 HoursEngine Oil Filter Filter Seal Prevent Crush Injury Fuel Filter 500 HoursEngine Tune-Up LubricationRefer to your engine manual for additional information Battery/Charging SystemCooling System Remove the Air Box Cover, Item DReplace guards and panels prior to starting the engine Replacing the BatteryRemove rear access panel Remove lower battery retainer, Item B, FigureTo Start Bladeshaft Rotation Belts and PulleysTo Stop Bladeshaft Rotation Blade Shaft Drive Belt Pump Drive Belt BeltTensioner PulleyRotary BeltTensioner 16 Nut Tensioner Nut Adjustment NotchesDrive System Alignment Blade AlignmentBlade Flange Puller Removing the Inner Blade Flange Blade Shaft Tolerance Inner Flange Inside Face Installing the Inner Blade FlangeCircuit Breakers Relay, Glow Plug DelayTimer Starter Relay Maximum Cut Depth AdjustmentCircuit Breakers and Starter Relays Raise-Lower System PTO Drive MaintenanceRaise-Lower System Troubleshooting Hydraulic Oil System R Control Adjustment Hydraulic System MaintenanceAdjustment Nut Rod End Push-Pull Cable Neutral Safety SwitchHydraulic System Remove the oil reservoir cap to speed oil draining Long Term StorageDecommissioning Saw/Components Symptom Possible Cause Solution PS7060 Multiquip SAW Troubleshooting Blade Troubleshooting PS7060 Multiquip SAW TroubleshootingPage PS7060 Multiquip SAW Electrical Diagramto SN AF3700155 PS7060 Multiquip SAW Electrical Diagram SN AF3700156 & UP Lift Cylinder Assembly Lift PumpReservoir PS7060 Multiquip SAW Hydraulic Schematic SN AF3700156 & UP Freight Policy Terms and Conditions of Sale PartsPage Your Local Dealer is United StatesMexico United Kingdom Canada Brazil
Related manuals
Manual 82 pages 54.16 Kb

PS706020, PS706036, PS706026 PS706030, PS706016 specifications

The Multiquip PS706026, PS706030, PS706036, and PS706020 are highly regarded in the world of portable generators, designed to offer optimum performance and reliability for various applications. These models showcase a blend of advanced technologies and user-friendly features, catering to both professional and residential needs.

One of the standout features of the Multiquip PS706 series is their robust and efficient engines, which deliver reliable power output. These generators are equipped with a powerful Honda engine, ensuring superior performance even in demanding conditions. The engines are designed to be fuel-efficient, allowing users to save on fuel costs while maximizing operational time.

Another significant aspect of the PS706 series is their electric start capability. This feature offers added convenience, enabling users to start the generator at the push of a button. Additionally, the generators are equipped with a recoil backup starter, ensuring that users have a reliable starting method in the event of an electrical failure.

The generators are built with a heavy-duty frame and are designed to withstand tough job site conditions. Their compact and portable design allows for easy transportation, making them an excellent choice for contractors, construction sites, and recreational use. The inclusion of rugged wheels and a comfortable handle ensures that moving the generator is hassle-free.

Moreover, the PS706 series showcases impressive noise-reduction technology. With a well-designed muffler system, these generators operate quietly, making them suitable for use in residential areas and during outdoor events where noise restrictions may apply.

Safety features are also paramount in the Multiquip PS706 series. They are equipped with circuit breakers to prevent overload and automatic low-oil shutdown to protect the engine from damage. This focus on safety ensures that users can operate the generators with peace of mind.

The PS706 series generators have multiple outlet options, providing versatility in power supply. Users can charge multiple devices simultaneously, thanks to the inclusion of 120V/240V receptacles and GFCI-protected outlets.

In summary, the Multiquip PS706026, PS706030, PS706036, and PS706020 generators are engineered with high-performance engines, easy starting options, and advanced safety features. Their durability, portability, and noise-reduction capabilities make them suitable for a wide range of applications, from construction to home backup power. With these models, users can expect reliable and efficient performance even in the most demanding environments.