Multiquip PS706020 Belts and Pulleys, To Stop Bladeshaft Rotation, To Start Bladeshaft Rotation

Page 45

PS7060 MULTIQUIP SAW — MAINTENANCE

Belts and Pulleys

This saw uses a pair of Blade Shaft Drive Belts, (5G 3VX 530) and a Hydrostatic Pump Belt, (AX-35).

2

Engine must be at idle when engaging or dis-engaging bladeshaft drive:

To STOP Bladeshaft Rotation:

Push rocker switch labeled BLADESHAFT forward. Engine will tilt forward, dis-engaging the drive belt.

1

3

1.Blade Shaft Drive Belt

2.Pump Drive Belt

3.BeltTensioner Pulley

Figure 49. Belt Locations

V-BeltTension

CAUTION

Keep belts clean of foreign material that may cause slippage. Never dress belts as this can cause premature failure.

The V-belt tension on this saw is automatically controlled by the hydraulic system that actuates the Blade Shaft Engage/ Disengage System. Hydraulic pressure exerted on the engine tilt cylinder applies force on the Belt Drive System to engage Bladeshaft rotation.

To START Bladeshaft Rotation:

Push rocker switch lableled BLADESHAFT backward. Engine will tilt back, engaging the belt drive.

1 2 3

5

4

1.Engine Sheave

2.Tensioner Nut

3.Tensioner Base

4.Jackshaft Pulley

5.Tensioner Pulley

Figure 50. Belt Drive System

PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08) — PAGE 45

Image 45
Contents Models Proposition 65WARNING SILICOSIS/RESPIRATORYWARNINGS PS7060 Multiquip SAW Table of Contents PS7060 Multiquip SAW Dimensions PS7060 Multiquip SAW Specifications Crated Weight Uncrated WeightBF3L2011 Transmission PumpTraining Checklist Training ChecklistDaily PRE-OPERATION Checklist Daily PRE-OPERATION ChecklistSafety Message Alert Symbols Safety Message Alert Symbols Always wear approved respiratory protectionAlways wear approved eye and hearing protection Do not operate or service this SafetyPS7060 Multiquip SAW Rules for Safe Operation Rules for Safe OperationAlways keep the work area well organized PS7060 Multiquip SAW Rules for Safe OperationDiamond Blade Safety Saw Lifting and Loading Safety Transporting Via truck/trailerNever transport the saw with the blade mounted Case the battery liquid dilute BatteryMaintenance Safety EmergenciesIntended Use FeaturesEngine Water SystemPage PS7060 Multiquip SAW Serial TAG Information Socket Connector Use to plug in optional light PS7060 Multiquip SAW Controls and IndicatorsAuxiliary Switch LeftWater FlowValve Meters water supplyBlade Wrench Light Assembly Rear Access PanelPS7060 Multiquip SAW Components Accelerator system PS7060 Multiquip SAW Basic Engine InformationOil in crankcase Oil Fill Cap Remove to add engine oilChoosing Proper Blade Size PS7060 Multiquip SAW Choosing Proper Blade SizeRatio Engine RPM / 2000 desired BS RPM =Blade RPM vs. Surface Feet Per Minute Sfpm Optimum Blade RPM RangeSpecifictoolsto be Used Installing the Blade PS7060 Multiquip SAW Installing the BladeAlign flange pin through the blade into the inner flange Blade Direction of Rotation Tightening Direction Right SidePS7060 Multiquip SAW Installing the Blade 12 In .48 cm Lbs 56.7-79.4 KgRemove existing blade. See previous section Order Blade GuardPS7060 Multiquip SAW Blade Guards Blade Guards with Standard Water SystemsConnect the water delivery hose to the Blade Guard. Figure PS7060 Multiquip SAW Water Delivery Systems Installing the Flange GuardStay-Level Handlebars SLH PS7060 Multiquip SAW SLH and BatteryFueling the Saw PS7060 Multiquip SAW Fueling the SAWHandle fuel safely Do not smoke while refuelingPointer Adjustment PS7060 Multiquip SAW Pointer AdjustmentCold Weather Operation Draining theWater SystemSetting the Depth Indicator PS7060 Multiquip SAW RAISE-LOWER ControlsTop View Raise Lower Controls PS7060 Multiquip SAW Bladeshaft Engage System PS7060 Multiquip SAW Operation Wheel Drive SystemStarting and Stoppingthe Engine PS7060 Multiquip SAW Operation Restarting After Running Out of FuelOperating Synopsis Avoid Injury PS7060 Multiquip SAW Loading and TransportingMaintenance PS7060 Multiquip SAW MaintenanceAir Cleaner Components PS7060 Multiquip SAW MaintenanceChanging Engine Oil And Filter Oil Filter 125 HoursEngine Oil Filter Filter Seal Engine Tune-Up Fuel Filter 500 HoursLubrication Prevent Crush InjuryCooling System Battery/Charging SystemRemove the Air Box Cover, Item D Refer to your engine manual for additional informationRemove rear access panel Replacing the BatteryRemove lower battery retainer, Item B, Figure Replace guards and panels prior to starting the engineTo Stop Bladeshaft Rotation Belts and PulleysBlade Shaft Drive Belt Pump Drive Belt BeltTensioner Pulley To Start Bladeshaft RotationRotary BeltTensioner 16 Nut Tensioner Nut Adjustment NotchesDrive System Alignment Blade AlignmentBlade Flange Puller Removing the Inner Blade Flange Blade Shaft Tolerance Inner Flange Inside Face Installing the Inner Blade FlangeCircuit Breakers Relay, Glow Plug DelayTimer Starter Relay Maximum Cut Depth AdjustmentCircuit Breakers and Starter Relays Raise-Lower System PTO Drive MaintenanceRaise-Lower System Troubleshooting Adjustment Nut Rod End R Control Adjustment Hydraulic System MaintenancePush-Pull Cable Neutral Safety Switch Hydraulic Oil SystemHydraulic System Remove the oil reservoir cap to speed oil draining Long Term StorageDecommissioning Saw/Components Symptom Possible Cause Solution PS7060 Multiquip SAW Troubleshooting Blade Troubleshooting PS7060 Multiquip SAW TroubleshootingPage PS7060 Multiquip SAW Electrical Diagramto SN AF3700155 PS7060 Multiquip SAW Electrical Diagram SN AF3700156 & UP Lift Cylinder Assembly Lift PumpReservoir PS7060 Multiquip SAW Hydraulic Schematic SN AF3700156 & UP Freight Policy Terms and Conditions of Sale PartsPage Mexico United Kingdom United StatesCanada Brazil Your Local Dealer is
Related manuals
Manual 82 pages 54.16 Kb

PS706020, PS706036, PS706026 PS706030, PS706016 specifications

The Multiquip PS706026, PS706030, PS706036, and PS706020 are highly regarded in the world of portable generators, designed to offer optimum performance and reliability for various applications. These models showcase a blend of advanced technologies and user-friendly features, catering to both professional and residential needs.

One of the standout features of the Multiquip PS706 series is their robust and efficient engines, which deliver reliable power output. These generators are equipped with a powerful Honda engine, ensuring superior performance even in demanding conditions. The engines are designed to be fuel-efficient, allowing users to save on fuel costs while maximizing operational time.

Another significant aspect of the PS706 series is their electric start capability. This feature offers added convenience, enabling users to start the generator at the push of a button. Additionally, the generators are equipped with a recoil backup starter, ensuring that users have a reliable starting method in the event of an electrical failure.

The generators are built with a heavy-duty frame and are designed to withstand tough job site conditions. Their compact and portable design allows for easy transportation, making them an excellent choice for contractors, construction sites, and recreational use. The inclusion of rugged wheels and a comfortable handle ensures that moving the generator is hassle-free.

Moreover, the PS706 series showcases impressive noise-reduction technology. With a well-designed muffler system, these generators operate quietly, making them suitable for use in residential areas and during outdoor events where noise restrictions may apply.

Safety features are also paramount in the Multiquip PS706 series. They are equipped with circuit breakers to prevent overload and automatic low-oil shutdown to protect the engine from damage. This focus on safety ensures that users can operate the generators with peace of mind.

The PS706 series generators have multiple outlet options, providing versatility in power supply. Users can charge multiple devices simultaneously, thanks to the inclusion of 120V/240V receptacles and GFCI-protected outlets.

In summary, the Multiquip PS706026, PS706030, PS706036, and PS706020 generators are engineered with high-performance engines, easy starting options, and advanced safety features. Their durability, portability, and noise-reduction capabilities make them suitable for a wide range of applications, from construction to home backup power. With these models, users can expect reliable and efficient performance even in the most demanding environments.