Multiquip PS706026 PS706030, PS706020, PS706036, PS706016 PS7060 Multiquip SAW Table of Contents

Page 4

PS7060 MULTIQUIP SAW TABLE OF CONTENTS

Proposition 65 Warning

2

Silicosis/Respiratory Warnings

3

Table of Contents

4

Dimensions

5

Specifications

6

Engine Specifications

7

Training Checklist

8

Daily Pre-Operation Checklist

9

Safety Message Alert Symbols

10-11

Rules For Safe Operation

12-16

Intended Use/Familiarization

17

Serial Tag Information

19

PS7060 — MULTIQUIP SAW

Controls and Indicators

20

 

Components

21

 

Basic Engine Information

22

 

Choosing Proper Blade Size

23-24

 

Specific Tools/Saw Blades

25

 

Installing the Blade

26-27

 

Blade Guards

28-29

 

Water Delivery System

30

 

SLH and Battery

31

 

Fueling the Saw

32

 

Pointer Adjustment

33

 

Raise/Lower Controls

34

 

Blade Shaft Engage/Dis-engage

35

 

Operation

36-37

 

Loading/Transporting

38

 

Maintenance

39-55

 

Troubleshooting

56-58

 

Electrical Diagram To SN AF3700155

60

 

Electrical Diagram SN AF3700156 & Up

61

 

Hydraulic Schematic To SN AF3700155

62

 

Hydraulic Schematic SN AF3700156 & Up

63

 

Terms and Condition of Sale

64

Specifications are subject to change without

 

 

notice.

PAGE 4 — PS7060 MULTIQUIP SAW • OPERATION MANUAL — REV. #2 (06/02/08)

Image 4
Contents Models Proposition 65WARNING SILICOSIS/RESPIRATORYWARNINGS PS7060 Multiquip SAW Table of Contents PS7060 Multiquip SAW Dimensions PS7060 Multiquip SAW Specifications Uncrated Weight Crated WeightBF3L2011 Transmission PumpTraining Checklist Training ChecklistDaily PRE-OPERATION Checklist Daily PRE-OPERATION ChecklistSafety Message Alert Symbols Always wear approved respiratory protection Safety Message Alert SymbolsAlways wear approved eye and hearing protection Safety Do not operate or service thisPS7060 Multiquip SAW Rules for Safe Operation Rules for Safe OperationPS7060 Multiquip SAW Rules for Safe Operation Always keep the work area well organizedDiamond Blade Safety Transporting Via truck/trailer Saw Lifting and Loading SafetyNever transport the saw with the blade mounted Battery Case the battery liquid diluteMaintenance Safety EmergenciesFeatures Intended UseEngine Water SystemPage PS7060 Multiquip SAW Serial TAG Information PS7060 Multiquip SAW Controls and Indicators Socket Connector Use to plug in optional lightAuxiliary Switch LeftWater FlowValve Meters water supplyRear Access Panel Blade Wrench Light AssemblyPS7060 Multiquip SAW Components PS7060 Multiquip SAW Basic Engine Information Accelerator systemOil in crankcase Oil Fill Cap Remove to add engine oilPS7060 Multiquip SAW Choosing Proper Blade Size Choosing Proper Blade SizeRatio Engine RPM / 2000 desired BS RPM =Optimum Blade RPM Range Blade RPM vs. Surface Feet Per Minute SfpmSpecifictoolsto be Used PS7060 Multiquip SAW Installing the Blade Installing the BladeAlign flange pin through the blade into the inner flange Blade Direction of Rotation Tightening Direction Right Side12 In .48 cm Lbs 56.7-79.4 Kg PS7060 Multiquip SAW Installing the BladeRemove existing blade. See previous section Blade Guard OrderBlade Guards with Standard Water Systems PS7060 Multiquip SAW Blade GuardsConnect the water delivery hose to the Blade Guard. Figure Installing the Flange Guard PS7060 Multiquip SAW Water Delivery SystemsPS7060 Multiquip SAW SLH and Battery Stay-Level Handlebars SLHPS7060 Multiquip SAW Fueling the SAW Fueling the SawHandle fuel safely Do not smoke while refuelingPS7060 Multiquip SAW Pointer Adjustment Pointer AdjustmentCold Weather Operation Draining theWater SystemPS7060 Multiquip SAW RAISE-LOWER Controls Setting the Depth IndicatorTop View Raise Lower Controls PS7060 Multiquip SAW Bladeshaft Engage System Wheel Drive System PS7060 Multiquip SAW OperationStarting and Stoppingthe Engine Restarting After Running Out of Fuel PS7060 Multiquip SAW OperationOperating Synopsis PS7060 Multiquip SAW Loading and Transporting Avoid InjuryPS7060 Multiquip SAW Maintenance MaintenancePS7060 Multiquip SAW Maintenance Air Cleaner ComponentsOil Filter 125 Hours Changing Engine Oil And FilterEngine Oil Filter Filter Seal Fuel Filter 500 Hours Engine Tune-UpLubrication Prevent Crush InjuryBattery/Charging System Cooling SystemRemove the Air Box Cover, Item D Refer to your engine manual for additional informationReplacing the Battery Remove rear access panelRemove lower battery retainer, Item B, Figure Replace guards and panels prior to starting the engineBelts and Pulleys To Stop Bladeshaft RotationBlade Shaft Drive Belt Pump Drive Belt BeltTensioner Pulley To Start Bladeshaft Rotation16 Nut Tensioner Nut Adjustment Notches Rotary BeltTensionerBlade Alignment Drive System AlignmentBlade Flange Puller Removing the Inner Blade Flange Installing the Inner Blade Flange Blade Shaft Tolerance Inner Flange Inside FaceMaximum Cut Depth Adjustment Circuit Breakers Relay, Glow Plug DelayTimer Starter RelayCircuit Breakers and Starter Relays PTO Drive Maintenance Raise-Lower SystemRaise-Lower System Troubleshooting R Control Adjustment Hydraulic System Maintenance Adjustment Nut Rod EndPush-Pull Cable Neutral Safety Switch Hydraulic Oil SystemHydraulic System Long Term Storage Remove the oil reservoir cap to speed oil drainingDecommissioning Saw/Components Symptom Possible Cause Solution PS7060 Multiquip SAW Troubleshooting PS7060 Multiquip SAW Troubleshooting Blade TroubleshootingPage PS7060 Multiquip SAW Electrical Diagramto SN AF3700155 PS7060 Multiquip SAW Electrical Diagram SN AF3700156 & UP Lift Pump Lift Cylinder AssemblyReservoir PS7060 Multiquip SAW Hydraulic Schematic SN AF3700156 & UP Terms and Conditions of Sale Parts Freight PolicyPage United States Mexico United KingdomCanada Brazil Your Local Dealer is
Related manuals
Manual 82 pages 54.16 Kb

PS706020, PS706036, PS706026 PS706030, PS706016 specifications

The Multiquip PS706026, PS706030, PS706036, and PS706020 are highly regarded in the world of portable generators, designed to offer optimum performance and reliability for various applications. These models showcase a blend of advanced technologies and user-friendly features, catering to both professional and residential needs.

One of the standout features of the Multiquip PS706 series is their robust and efficient engines, which deliver reliable power output. These generators are equipped with a powerful Honda engine, ensuring superior performance even in demanding conditions. The engines are designed to be fuel-efficient, allowing users to save on fuel costs while maximizing operational time.

Another significant aspect of the PS706 series is their electric start capability. This feature offers added convenience, enabling users to start the generator at the push of a button. Additionally, the generators are equipped with a recoil backup starter, ensuring that users have a reliable starting method in the event of an electrical failure.

The generators are built with a heavy-duty frame and are designed to withstand tough job site conditions. Their compact and portable design allows for easy transportation, making them an excellent choice for contractors, construction sites, and recreational use. The inclusion of rugged wheels and a comfortable handle ensures that moving the generator is hassle-free.

Moreover, the PS706 series showcases impressive noise-reduction technology. With a well-designed muffler system, these generators operate quietly, making them suitable for use in residential areas and during outdoor events where noise restrictions may apply.

Safety features are also paramount in the Multiquip PS706 series. They are equipped with circuit breakers to prevent overload and automatic low-oil shutdown to protect the engine from damage. This focus on safety ensures that users can operate the generators with peace of mind.

The PS706 series generators have multiple outlet options, providing versatility in power supply. Users can charge multiple devices simultaneously, thanks to the inclusion of 120V/240V receptacles and GFCI-protected outlets.

In summary, the Multiquip PS706026, PS706030, PS706036, and PS706020 generators are engineered with high-performance engines, easy starting options, and advanced safety features. Their durability, portability, and noise-reduction capabilities make them suitable for a wide range of applications, from construction to home backup power. With these models, users can expect reliable and efficient performance even in the most demanding environments.